Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
06.06.17 PZ Packet
] 1. Call to Order / Roll Call. 2. Pledge of Allegiance. 3. CONSENT AGENDA (Items placed on the Consent Agenda are considered routine in nature and are considered non- controversial. The Consent Agenda can be acted upon in one motion. A Planning & Zoning Commissioner may remove any item for discussion and separate action. Planning & Zoning Commissioners may vote nay on any single item without comment and may submit written comments as part of the official record.) 3a. Consider and act upon minutes from the May 16, 2017, Regular Planning & Zoning Commission meetings. 3b. Consider and act upon a Site Plan for a restaurant with drive-through in Gates of Prosper (Whataburger), on 2.0± acres, located on the east side of Preston Road, 1,000± feet north of US 380. This property is zoned Planned Development-67 (PD-67). (D17- 0034). 3c. Consider and act upon a Final Plat for Gates of Prosper, Block A, Lot 6, on 2.0± acres, located on the east side of Preston Road, 1,000± feet north of US 380. This property is zoned Planned Development-67 (PD-67). (D17-0035). REGULAR AGENDA If you wish to address the Planning & Zoning Commission during the regular agenda, please fill out a “Speaker Request Form” and present it to the Chair prior to the meeting. Citizens wishing to address the Planning & Zoning Commission for items listed as public hearings will be recognized by the Chair. Those wishing to speak on a non-public hearing related item will be recognized on a case-by-case basis, at the discretion of the Planning & Zoning Commission. 4. Consider and act upon a Site Plan for a retail/restaurant building (North Preston Village), on 2.2± acres, located on the east side of Preston Road, 2,000± feet south of Prosper Trail. This property is zoned Retail (R). (D17-0029). 5. Consider and act upon a request for a Façade Exception for the Gates of Prosper (Dick’s Sporting Goods / Field & Stream), located on the northwest corner of US 380 and Lovers Lane. (MD16-0019). 6. Consider and act upon a request for a Façade Exception for Bryant’s Addition, Block 23, Lot 3R (307 E. First Street), located on the northwest corner of Church Street and First Street. (MD17-0004). 7. Review actions taken by the Town Council and possibly direct Town Staff to schedule topic(s) for discussion at a future meeting. 8. Adjourn. AGENDA Regular Meeting of the Prosper Planning & Zoning Commission 108 W. Broadway St., Prosper, Texas Town of Prosper Municipal Chambers Tuesday, June 6, 2017, 6:00 p.m. Prosper is a place where everyone matters. Note: The order in which items are heard on the agenda is subject to change. CERTIFICATION I, the undersigned authority, do hereby certify that this Notice of Meeting was posted on the inside window at the Town Hall of the Town of Prosper, Texas, a place convenient and readily accessible to the general public at all times, and said Notice was posted on June 2, 2017, at 5:00 p.m. and remained so posted at least 72 hours before said meeting was convened. ______________________________________________ _________________________ Robyn Battle, Town Secretary Date Notice Removed Pursuant to Section 551.071 of the Texas Government Code, the Planning & Zoning Commission reserves the right to consult in closed session with its attorney and to receive legal advice regarding any item listed on this agenda. NOTICE Pursuant to Town of Prosper Ordinance No. 13-63, all speakers other than Town of Prosper staff are limited to three (3) minutes per person, per item, which may be extended for an additional two (2) minutes with approval of a majority vote of the Planning & Zoning Commission. NOTICE OF ASSISTANCE AT PUBLIC MEETINGS: The Prosper Planning & Zoning Commission meetings are wheelchair accessible. For special services or assistance, please contact the Town Secretary’s Office at (972) 569- 1011 at least 48 hours prior to the meeting time. ] 1. Call to Order / Roll Call. The meeting was called to order at 6:00 p.m. Commissioners present: Chairman John Alzner, Vice Chairman John Hema, Secretary Brandon Daniel, Craig Andres, and Chad Robertson Commissioner absent: Bobby Atteberry Staff present: John Webb, Director of Development Services; Alex Glushko, Senior Planner; and Pamela Clark, Planning Technician 2. Recitation of the Pledge of Allegiance. 3. CONSENT AGENDA 3a. Consider and act upon minutes from the April 18, 2017, Regular Planning & Zoning Commission meetings. 3b. Consider and act upon an Amending Plat of the Railroad Addition, Block 27, Lot 1G, on 0.7± acre, on the southwest corner of Fifth Street and McKinley Street. The property is zoned Downtown Commercial (DTC). (D17-0027). 3c. Consider and act upon a Site Plan for an office building, on 0.1± acre, located on the west side of Main Street, 100± feet south of Broadway Street. The property is zoned Planned Development-78 (PD-78). (D17-0028). 3d. Consider and act upon a Preliminary Plat for Preserve at Doe Creek, for 121 single family residential lots and ten (10) HOA/open space lots, on 47.6± acres, located on the south side of Fishtrap Road, 1,450 feet east of FM 1385. The property is zoned Planned Development-53 (PD-53). (D17-0032). 3e. Consider and act upon a Final Plat for Preserve at Doe Creek, Phase 2, for 69 single family residential lots and one (1) HOA/open space lot, on 24.2± acres, located 1,000± feet south of Fishtrap Road, 1,450 feet east of FM 1385. This property is zoned Planned Development-53 (PD-53). (D17-0033). Motioned by Robertson, seconded by Daniel, to approve the Consent Agenda, subject to staff recommendations. Motion approved 5-0. REGULAR AGENDA 4. Consider and act upon a Site Plan for 19 Temporary Buildings at Reynolds Middle School, on 73.8± acres, located on the east side of Coleman Street, 2,000± south of Prosper Trail. This property is zoned Single Family-15 (SF-15). (D17-0026). AGENDA Regular Meeting of the Prosper Planning & Zoning Commission 108 W. Broadway St., Prosper, Texas Town of Prosper Municipal Chambers Tuesday, May 16, 2017, 6:00 p.m. Prosper is a place where everyone matters. Prosper Planning & Zoning Commission Meeting Minutes of May 16, 2017 Glushko: Summarized the request and presented exhibits showing the existing temporary buildings and the location of the proposed temporary buildings. Stated the buildings must abide by the same setbacks as the main building, and that each building is required to have ten feet of separation for fire coverage. Danny Roberts (Prosper Independent School District Representative): Provided information on a possible future site for a middle school. Explained that the district is presently working on plans for another middle school. Stated that each classroom has a seating capacity of 25 student and that each of the proposed buildings has two classrooms. Commissioners voiced concerns about the temporary buildings, but realized they were necessary to accommodate the growth in the District. Motioned by Hema, seconded by Andres, to approve Item 4, subject to staff recommendations. Motion approved 5-0. 5. Consider and act upon a Site Plan for a retail/restaurant building (North Preston Village), on 2.2± acres, located on the east side of Preston Road, 2,000± feet south of Prosper Trail. This property is zoned Retail (R). (D17-0029). 6. Consider and act upon a Conveyance Plat of North Preston Village, Block A, Lots 1 and 2, on 7.1± acres, located on the east side of Preston Road, 2,000± feet south of Prosper Trail. This property is zoned Retail (R). (D17-0030). 7. Consider and act upon a Final Plat of North Preston Village, Block A, Lot 1, on 2.0± acres, located on the east side of Preston Road, 2,000± feet south of Prosper Trail. This property is zoned Retail (R). (D17-0031). Glushko: Summarized the requests and presented exhibits provided by the applicant. Informed Commissioners that staff has concerns regarding the location of the majority of the required parking being at the rear of the building. David Bond (Applicant): Stated if the primary users are retail, all the required parking for that use is available in front of the building. Informed Commissioners that the additional parking in the rear of the building gives the flexibility to allow for restaurant users, if needed. Commissioners voiced concerns about the location of the parking, specifically regarding the inconvenience due to proximity to the businesses for tenants and customers, and the lack of rear access into businesses. The Commission requested the applicant provide additional options to allow for more convenient access to parking. Motioned by Daniel, seconded by Hema, to table Item 5, to allow the applicant an opportunity to address the Commission’s concerns regarding the parking location. Motion approved 5-0. Motioned by Robertson, seconded by Andres, to approve Items 6 and 7, subject to staff recommendations. Motion approved 5-0. 8. Conduct a Public Hearing, and consider and act upon a request for a Specific Use Permit for a Utility Distribution/Transmission Facility, on 0.1± acre, located on the northwest corner of Fishtrap Road and FM 1385. The property is zoned Retail (R). (S17-0002). Prosper Planning & Zoning Commission Meeting Minutes of May 16, 2017 Glushko: Summarized the request and presented exhibits provided by the applicant. Informed Commissioners that one Public Hearing Reply Form has been received, not in opposition to the request. Recommended approval of the request. Chairman Alzner opened the Public Hearing. James Koehler (Applicant): Provided information on why the location was chosen and the need for the metering station. Webb: Informed the Commission about the future realignment of F.M. 1385 and Gee Road. There being no other speakers, the Public Hearing was closed. Commissioners voiced support for the request. Motioned by Robertson, seconded by Hema, to approve Item 8, subject to staff recommendations. Motion approved 5-0. 9. Review actions taken by the Town Council and possibly direct Town Staff to schedule topic(s) for discussion at a future meeting. Webb: Provided a summary of recent actions taken by Town Council. 10. Adjourn. Motioned by Robertson, seconded by Daniel, to adjourn. Motion approved 5-0 at 7:15 p.m ______________________________ _________________________ Pamela Clark, Planning Technician Brandon Daniel, Secretary Page 1 of 1 To: Planning & Zoning Commission From: Alex Glushko, AICP, Senior Planner Through: John Webb, AICP, Director of Development Services Re: Planning & Zoning Commission Meeting – June 6, 2017 Agenda Item: Consider and act upon a Site Plan for a restaurant with drive-through in Gates of Prosper (Whataburger), on 2.0± acres, located on the east side of Preston Road, 1,000± feet north of US 380. This property is zoned Planned Development-67 (PD-67). (D17-0034). Description of Agenda Item: The Site Plan shows one 3,578 square foot restaurant with a drive-through in Gates of Prosper (Whataburger). Access is provided from Preston Road. Adequate parking has been provided. The Site Plan conforms to the PD-67 development standards. As a companion item, the Final Plat for Gates of Prosper, Block A, Lot 6 (D17-0035) is on the June 6, 2017, agenda. Attached Documents: 1. Location Map 2. Site Plan Town Staff Recommendation: Town staff recommends approval of the Site Plan subject to: 1. Town staff approval of civil engineering, irrigation plans, open space plans, façade and address plans. 2. Town staff approval of all fire hydrants, fire department connections (FDC) and fire lanes, including widths, radii, and location. Prosper is a place where everyone matters. PLANNING UNIVERSITY DR RICHLAND BLVD COLEMAN STPRESTON RDD17-0034 ±0 120 240 36060Feet Page 1 of 1 To: Planning & Zoning Commission From: Alex Glushko, AICP, Senior Planner Through: John Webb, AICP, Director of Development Services Re: Planning & Zoning Commission Meeting – June 6, 2017 Agenda Item: Consider and act upon a Final Plat for Gates of Prosper, Block A, Lot 6, on 2.0± acres, located on the east side of Preston Road, 1,000± feet north of US 380. This property is zoned Planned Development-67 (PD-67). (D17-0035). Description of Agenda Item: The Final Plat dedicates all easements necessary for development and conforms to the PD-67 development standards. As a companion item, the Site Plan for a restaurant with a drive-through in Gates of Prosper (Whataburger), D17-0008, is on the June 6, 2017 agenda. Legal Obligations and Review: The Final Plat meets minimum development requirements. Attached Documents: 1. Location Map 2. Final Plat Town Staff Recommendation: Town staff recommends approval of the Final Plat, subject to: 1. Town staff approval of all additions and/or alterations to the easements and dedications on the Final Plat. Prosper is a place where everyone matters. PLANNING UNIVERSITY DR RICHLAND BLVD COLEMAN STPRESTON RDD17-0035 ±0 120 240 36060Feet B E N R E N I S O N S U R V E Y A B S T R A C T N O. 7 5 5 Δ VICINITY MAP NTS SH 289 PRESTON RDUS 380 UNIVERSITY DR NORTH DALLAS TOLLWAYCOLEMAN STPROSPER FRISCOR.R.1ST ST C.R. 73DETAIL 'A' AREA TO BE VACATED 1"=30' “” ” “” ” “” ” “” ”” “” ” “” ’’ Page 1 of 2 To: Planning & Zoning Commission From: Alex Glushko, AICP, Senior Planner Through: John Webb, AICP, Director of Development Services Re: Planning & Zoning Commission Meeting – June 6, 2017 Agenda Item: Consider and act upon a Site Plan for a retail/restaurant building (North Preston Village), on 2.2± acres, located on the east side of Preston Road, 2,000± feet south of Prosper Trail. This property is zoned Retail (R). (D17-0029). History: At the May 16, 2017, meeting, the Planning & Zoning Commission tabled this request to allow the applicant an opportunity to consider options to address staff and Commission concerns regarding the site layout, specifically regarding the location and convenience of the proposed parking as described below. Since the meeting, the applicant took the following actions: 1. Revised the Site Plan by increasing the sidewalk south of the building from 5 feet to 8 feet; 2. Provided a letter addressing staff and Commission concerns; and 3. Provided a letter from a commercial broker describing trends toward this type of development layout and the appropriateness of the design. Description of Agenda Item: The Site Plan shows a proposed 14,304 square foot, one-story, retail/restaurant building. Access is provided from Preston Road and Hays Road. Adequate parking has been provided. The Site Plan conforms to the Retail development standards. According to the Zoning Ordinance, the Planning & Zoning Commission may approve, conditionally approve or deny the application based upon the design and location of off-street parking and loading facilities to ensure that all such spaces are usable and are safely and conveniently arranged. Staff has concerns with the percentage of parking that has been provided in the rear/east of the building, considering the front entrances to each of the lease spaces will be accessed in the front/west of the building. Approximately 60% of the 105 parking spaces will be located toward the rear of the center. While it is customary to provide parking for staff toward the rear of a retail center, customers will not have convenient parking available, and will be routed through the service area to access the respective businesses. The applicant has indicated that the double row of parking in the front with the additional parking field in the rear is an intentional design, in order to provide additional visibility to the building and Prosper is a place where everyone matters. PLANNING Page 2 of 2 businesses from Preston Road, and that the rear parking provides the flexibility to accommodate restaurant uses within the building. Attached Documents: 1. Location Map 2. Site Plan 3. Applicant Response Letter 4. Broker Letter 5. Façade Plan (for informational purposes only) Staff Recommendation: Staff recommends approval of the Site Plan subject to: 1. Staff approval of civil engineering, landscape, irrigation, open space, façade and address plans. 2. Staff approval of all fire hydrants, fire department connections (FDC) and fire lanes, including widths, radii, and location. PRESTON RDHIGHPOINT DR P R E S T O N V I E W D R WEST YORKSHIRE DRHICKORY CREEK DR CREEK VIEW DR HAYS RDPASEWARK CIR D17-0029 ±0 110 220 33055Feet LOCATION MAP 1" = 1000' PROJECT LOCATION Scale: 1"=40' May, 2017 SEI Job No. 17-029 Town Case No. D17-0029 SITE PLAN NORTH PRESTON VILLAGE BLOCK A, LOT 1 IN THE TOWN OF PROSPER, COLLIN COUNTY, TEXAS J. TUNNEY SURVEY, ABST. NO. 916 87,007 Sq. Ft./ 1.997 Acres (Gross) 95,762 Sq. Ft./ 2.198 Acres (Net) Current Zoning: R (Retail) OWNER / APPLICANT BG-GBT North Preston Village, LP 9550 John W. Elliott Dr., Suite 106 Frisco, TX 75033 Telephone: (214) 972-0808 Contact: Ryan Griffin ENGINEER / SURVEYOR Spiars Engineering, Inc. 765 Custer Road, Suite 100 Plano, TX 75075 Telephone: (972) 422-0077 TBPE No. F-2121 Contact: David Bond Cab. Q, Pg. 680 PRCCT Doc. No. 96-0054009 DRCCT Doc. No. 20150113000038940 DRCCT Doc. No. 20100929001043970 DRCCT Vol. 12, Pg. 51 DRCCT Doc. No. 20150821001059600 DRCCT (corrected deed recorded in Doc. No. 20150914001163560 DRCCT)(Prescriptive R.O.W.)Variable width R.O.W.Vol. 2012, Pg. 84 PRCCT (Unrecorded) 陰诲诲 睈睊 睊˅@˅ ″ Page 1 of 3 To: Planning & Zoning Commission From: Alex Glushko, AICP, Senior Planner Through: John Webb, AICP, Director of Development Services Re: Planning & Zoning Commission Meeting – June 6, 2017 Agenda Item: Consider and act upon a request for a Façade Exception for the Gates of Prosper (Dick’s Sporting Goods / Field & Stream), located on the northwest corner of US 380 and Lovers Lane. (MD16-0019). Description of Agenda Item: At the July 12, 2016, meeting, the Town Council approved a Façade Exception for the Gates of Prosper (Dick’s Sporting Goods / Field & Stream), included as Attachment 2. The approved plan does not depict the location of the rooftop mechanical equipment and indicates the mechanical equipment will be screened, as required by the Zoning Ordinance. The Zoning Ordinance requires all mechanical equipment to be screened from view at a point six (6) feet above ground level at the property line. If a parapet does not accomplish this screening, a screening wall equal to the height of the equipment shall be provided, to be constructed of clay-fired brick masonry units or other suitable permanent materials which do not contain openings constituting more than forty (40) square inches in each one square foot of wall or fence surface. In conjunction with routine Zoning compliance inspections of commercial construction, Town staff identified the installation of rooftop mechanical equipment which were not screened in accordance with the Zoning Ordinance, and notified the general contractor accordingly. The applicant is seeking a Façade Exception for Dick’s Sporting Goods / Field & Stream to allow for an alternative type of device to screen the rooftop mechanical equipment, since the parapet wall does not achieve the required screening. The applicant is proposing to utilize 26 gauge steel with SmartKote Cool Coating devices painted in Surrey Beige to screen the rooftop mechanical equipment. As noted in the attached request letter from the applicant, this request is necessitated by the existing topography of the site. The property lines are 16 feet higher than the finished floor elevation of the building, which cause the rooftop mechanical equipment to become visible. Prosper is a place where everyone matters. PLANNING Page 2 of 3 The following is the view of the front of the building from the north: The following is the view from Lovers Lane on the east side of the building: In considering an exception to the required masonry requirements, the Planning & Zoning Commission and Town Council may consider whether a proposed alternate material: (a) is a unique architectural expression; (b) includes unique building styles and materials; (c) is consistent with high quality development; Page 3 of 3 (d) is or would be visually harmoniousness with existing or proposed nearby buildings; (e) has obvious merit based upon the quality and durability of the materials; and (f) represents an exterior building material that is in keeping with the intent of this chapter to balance the above mentioned objectives. Please reference the attached letter from the applicant addressing the aforementioned criteria in support of the request. Attachments: 1. Location Map 2. Approved Façade and Site Plans 3. Proposed Façade Plan 4. Screening Exhibits 5. Request Letter Town Staff Recommendation: Town staff recommends that the Planning & Zoning Commission consider and act upon a request for a Façade Exception for the Gates of Prosper (Dick’s Sporting Goods / Field & Stream). Town Council Consideration: Upon a recommendation by the Planning & Zoning Commission, this request will be scheduled for the Town Council meeting on June 27, 2017. UNIVERSITY DRPRESTON RDRICHLAND BLVD LOVERS LNLANC ER LN WHISTLER LN MYSTIC WAYH A WT H O R N D R DREXEL LNSTRATFO RD DR MD17-0003 ±0 180 360 54090Feet 45' - 0"SIGNMETAL ACCENTSIGNCORNICEGL-1WD-56WD-56WD-57ST-1ST-1MT-55ST-1CMU-1BRK-1CTC-2CTC-1CORNICEP-51WD-5517' - 0"8' - 0"17' - 0"8' - 0"MT-63COPINGMT-63COPINGMT-63WD-55CTC-1T/ MASONRY25' - 0"T/ MASONRY45' - 0"GL-2GL-218' - 0"20' - 8"ST-1ST-1ST-1WD-56.WD-5545' - 0"CORNICEWD-56ST-1ST-1MT-55CTC-3CTC-316' - 4"8' - 6"25' - 0"MT-63COPING25' - 4"20' - 8"ST-1ST-1ST-1ST-1MT-634' - 0"10' - 0"15' - 1 1/2"8' - 7"15' - 1 1/2"8' - 7"2' - 6"6' - 0"41' - 0"6' - 0"2' - 6"8' - 4"15' - 1 1/2"8' - 4 1/2"15' - 10"8' - 4"4' - 0"4' - 0"29' - 2 1/2"4' - 0"30' - 0"4' - 0"17' - 0"4' - 8"49' - 5"4' - 8"17' - 0"4' - 0"30' - 0"4' - 0"24' - 4"4' - 0"6' - 0"TYP.1' - 3 1/2"4' - 10"1' - 2"TYP.1' - 6"4' - 0"61' - 5"58' - 0"60' - 0"88' - 3"58' - 9"82' - 1"178' - 0"229' - 0"4' - 0"28' - 7 1/2"4' - 0"26' - 0"4' - 0"26' - 0"4' - 0"26' - 0"4' - 0"26' - 0"4' - 0"30' - 0"4' - 0"4' - 0"4' - 0"TYP.1' - 3"3' - 10"8' - 0"4' - 2"8' - 0"2' - 0"26' - 0"188' - 0"2341188' - 0"24' - 8"407' - 0"188' - 0"24' - 8"www.FRCH.com311 Elm Street | Suite 600 | Cincinnati, OH 45202Telephone 513.241.3000 | Facsimile 513.241.5015Contact InformationSheet Issue InformationSheet Information© 2012 This drawing, printed or otherwise, is the copyrighted property of FRCH Design Worldwide and FRCH/Architecture, Inc., P.C. The drawing may not be used, reproduced or copied without the permission of FRCH Design Worldwide or FRCH/Architecture, Inc., P.C.TitleDrawn By:IssuedArchitecturep: (513) 241-3000Ownerp: (724) 273-3400Dick's Sporting Goods345 Court StreetCoraopolis, PA 15108FRCH Architecture Inc.311 Elm Street, Suite 600Cincinnati, OH 45202Project No.Interior Design p: (513) 241-3000FRCH Design Worldwide311 Elm Street, Suite 600Cincinnati, OH 45202FRCH/Architecture, Inc., P.C.GATES OF PROSPER LOT-4 BLOCK-APROSPER, TX32732.000 / #4622EXTERIORELEVATIONSA. FUGAZZI003aBRK-1REFER TO SPECIFICATION SECTION 04200 FOR ACCEPTABLE MANUFACTURERS. MORTAR - ARGOS #127ST-1MANUFACTURER: CENTURIAN STONE - PATTERN #040 PALOS VERDE - COLOR: #786 ASPEN.GL-1AMBER COLORED GLASSGL-2CLEAR GLASS w/ GRAPHIC IMAGEWD-55MANUFACTURER: ARRIGONI WOODS - RECLAIMED MATERIAL SUNBURNT SIDING - FINISH: NATURALWD-56MANUFACTURER: ARRIGONI WOODS - RECLAIMED MATERIAL SUNBURNT SIDING - FINISH: STAINEDWD-57MANUFACTURER: WESTERN WOOD PRODUCTS ASSOCIATION - 2x8 QTR LOG CABIN SIDING w/ REVEAL; PERMA-CHINK-BEIGE #216 - FINISH: STAINEDMT-55MANUFACTURER: INNOVATIVE POWDER COATINGS - PRODUCT: TRANS BLACK G50MT-63 METAL ACM/COPING - COLOR: HARTFORD GREENCMU-1SMOOTH-FACE CENTER SCORED MASONRY UNIT. STAIN TO MATCH SW 0028 CAEN STONECTC-1CONCRETE TILT-UP WALL w/ TEXTURED COATING. COLOR TO MATCH SW 0028 CAEN STONECTC-2CONCRETE TILT-UP WALL w/ SMOOTH COATING. COLOR TO MATCH P-52 DSG BELDONCTC-3 CONCRETE TILT-UP WALL w/ TEXTURED COATING. COLOR TO MATCH BENJAMIN MOORE HC-124 CALDWELL GREENP-124MANUFACTURER:SHERWIN WILLIAMS - COLOR: TO MATCH DUNN EDWARDS DE6399 MOLASSES LRV 7 - FINISH: SATINP-152MANUFACTURER: SHERWIN WILLIAMS - COLOR: FS CUSTOM ORANGE PMS 158CFINISH SCHEDULEPRIMARY MATERIALSST-1 = 2,215 sq. ft.21%CTC-1 = 2,845 sq. ft.27%BRK-1 = 945 sq. ft.9%SECONDARY MATERIALSWD-55 = 695 sq. ft.7%WD-56 = 765 sq. ft.7%WD-57 = 1,080 sq. ft. 10%GL-1 = 375 sq. ft. 4%GL-2 = 310 sq. ft.3%MT-55 = 125 sq. ft. 1%MT-63 = 1,200 sq. ft. 11%1. NORTH (FRONT) ELEVATIONTOTAL ELEVATION AREA = 11,935 sq. ft.WINDOWS AND DOORS AREA = 1,380 sq. ft.NET ELEVATION AREA = 10,555 sq. ft.PRIMARY MATERIALSST-1 = 1,815 sq. ft. 36%CTC-3 = 2,960 sq. ft. 58%SECONDARY MATERIALSWD-56 = 195 sq. ft. 4%MT-55 = 110 sq. ft. 2%2. EAST (SIDE) ELEVATIONTOTAL ELEVATION AREA = 5,225 sq. ft.WINDOWS AND DOORS AREA = 145 sq. ft.NET ELEVATION AREA = 5,080 sq. ft.# Description Date1 SITE PLANSUBMITTAL05.09.20162 UPDATE05.24.20163 UPDATE06.01.20164 UPDATE06.22.2016SCALE: 1/16" = 1'-0"SCALE: 1/16" = 1'-0"• “This Facade Plan is for conceptual purposes only. All building plans require review and approvalfrom the Building Inspection Department”• "All mechanical equipment shall be screened from public view in accordance with the ZoningOrdinance"• “When permitted, exposed utility boxes and conduits shall be painted to match the building”• "All signage areas and locations are subject to approval by the Building Inspections Department"• “Windows shall have a maximum exterior visible reflectivity of ten (10) percent.”• “Entrance elements above 25' height are non-habitable elements integral to the building design.”FACADE PLAN CHECKLISTNKEY PLANBlock A, Lot 47/12/2016 Town Council Façade Exception Approved CORNICEP-51ST-1ST-1MT-55ST-1CTC-3SIGNSIGNMT-55CMU-1STAIN-1BRK-1CTC-1P-124ORANGE PAINTP-152CORNICEWD-56CTC-3ST-1MT-558' - 0"17' - 0"25' - 0"8' - 0"17' - 0"25' - 0"MT-63COPINGMT-63COPINGCTC-1EL= 27' - 0" AFFST-1ST-1MT-55ST-1BRK-1BRK-1ST-1ST-114' - 0"14' - 0"ST-1CMU-1BRK-1CTC-2CTC-1CORNICEP-51CTC-1CORNICEP-51MT-5525' - 0"8' - 0"16' - 10"25' - 0"8' - 0"16' - 10"MT-63COPING80' - 0"92' - 3 3/4"40' - 0"27' - 1 5/8"4' - 0"30' - 0"4' - 0"30' - 0"4' - 0"30' - 0"4' - 0"4' - 0"1' - 4"1' - 4"26' - 0"26' - 0"4' - 0"1' - 4"LOADING DOCKCOMPACTOR4' - 0"30' - 0"4' - 0"30' - 0"4' - 0"30' - 0"4' - 0"30' - 0"4' - 0"44' - 8 7/8"4' - 0"36' - 0"4' - 0"36' - 0"4' - 0"38' - 1 7/8"8' - 0"38' - 1 7/8"4' - 0"36' - 0"4' - 0"4' - 0"4' - 0"28' - 7 1/2"4' - 0"26' - 0"4' - 0"26' - 0"4' - 0"26' - 0"4' - 0"26' - 0"4' - 0"30' - 0"4' - 0"4' - 0"TYP.1' - 3 1/2"188' - 0"26' - 0"2341407' - 0"24' - 8"188' - 0"188' - 0"24' - 8"www.FRCH.com311 Elm Street | Suite 600 | Cincinnati, OH 45202Telephone 513.241.3000 | Facsimile 513.241.5015Contact InformationSheet Issue InformationSheet Information© 2012 This drawing, printed or otherwise, is the copyrighted property of FRCH Design Worldwide and FRCH/Architecture, Inc., P.C. The drawing may not be used, reproduced or copied without the permission of FRCH Design Worldwide or FRCH/Architecture, Inc., P.C.TitleDrawn By:IssuedArchitecturep: (513) 241-3000Ownerp: (724) 273-3400Dick's Sporting Goods345 Court StreetCoraopolis, PA 15108FRCH Architecture Inc.311 Elm Street, Suite 600Cincinnati, OH 45202Project No.Interior Design p: (513) 241-3000FRCH Design Worldwide311 Elm Street, Suite 600Cincinnati, OH 45202FRCH/Architecture, Inc., P.C.GATES OF PROSPER LOT-4 BLOCK-APROSPER, TX32732.000 / #4622EXTERIORELEVATIONSA. FUGAZZI003b4. WEST (SIDE) ELEVATIONBRK-1REFER TO SPECIFICATION SECTION 04200 FOR ACCEPTABLE MANUFACTURERS. MORTAR - ARGOS #127ST-1MANUFACTURER: CENTURIAN STONE - PATTERN #040 PALOS VERDE - COLOR: #786 ASPEN.GL-1AMBER COLORED GLASSGL-2CLEAR GLASS w/ GRAPHIC IMAGEWD-55MANUFACTURER: ARRIGONI WOODS - RECLAIMED MATERIAL SUNBURNT SIDING - FINISH: NATURALWD-56MANUFACTURER: ARRIGONI WOODS - RECLAIMED MATERIAL SUNBURNT SIDING - FINISH: STAINEDWD-57MANUFACTURER: WESTERN WOOD PRODUCTS ASSOCIATION - 2x8 QTR LOG CABIN SIDING w/ REVEAL; PERMA-CHINK-BEIGE #216 - FINISH: STAINEDMT-55MANUFACTURER: INNOVATIVE POWDER COATINGS - PRODUCT: TRANS BLACK G50MT-63 METAL ACM/COPING - COLOR: HARTFORD GREENCMU-1SMOOTH-FACE CENTER SCORED MASONRY UNIT. STAIN TO MATCH SW 0028 CAEN STONECTC-1CONCRETE TILT-UP WALL w/ TEXTURED COATING. COLOR TO MATCH SW 0028 CAEN STONECTC-2CONCRETE TILT-UP WALL w/ SMOOTH COATING. COLOR TO MATCH P-52 DSG BELDONCTC-3 CONCRETE TILT-UP WALL w/ TEXTURED COATING. COLOR TO MATCH BENJAMIN MOORE HC-124 CALDWELL GREENP-124MANUFACTURER:SHERWIN WILLIAMS - COLOR: TO MATCH DUNN EDWARDS DE6399 MOLASSES LRV 7 - FINISH: SATINP-152MANUFACTURER: SHERWIN WILLIAMS - COLOR: FS CUSTOM ORANGE PMS 158CFINISH SCHEDULEPRIMARY MATERIALSST-1 = 3,315 sq. ft.33%CTC-1 = 2,830 sq. ft. 28%CTC-3 = 3,700 sq. ft. 37%SECONDARY MATERIALSMT-55 = 200 sq. ft.2%3. SOUTH (REAR) ELEVATIONTOTAL ELEVATION AREA = 10,045 sq. ft.WINDOWS AND DOORS AREA = 0 sq. ft.NET ELEVATION AREA = 10,045 sq. ft.NKEY PLAN# Description Date1 SITE PLANSUBMITTAL05.09.20162 UPDATE05.24.20163 UPDATE06.01.20164 UPDATE06.22.2016SCALE: 1/16" = 1'-0"• “This Facade Plan is for conceptual purposes only. All building plans require review and approvalfrom the Building Inspection Department”• "All mechanical equipment shall be screened from public view in accordance with the ZoningOrdinance"• “When permitted, exposed utility boxes and conduits shall be painted to match the building”• "All signage areas and locations are subject to approval by the Building Inspections Department"• “Windows shall have a maximum exterior visible reflectivity of ten (10) percent.”• “Entrance elements above 25' height are non-habitable elements integral to the building design.”FACADE PLAN CHECKLISTSCALE: 1/16" = 1'-0"PRIMARY MATERIALSST-1 = 1,195 sq. ft.24%CTC-1 = 3,014 sq. ft. 58%BRK-1 = 842 sq. ft. 16%SECONDARY MATERIALSMT-55 = 108 sq. ft.2%TOTAL ELEVATION AREA = 5,175 sq. ft.WINDOWS AND DOORS AREA = 16 sq. ft.NET ELEVATION AREA = 5,159 sq. ft.Block A, Lot 407/12/2016 Town Council Façade Exception Approved 00 50'100' GRAPHIC SCALE 50' ANY REVISION TO THIS PLAN WILL REQUIRE TOWN APPROVAL AND WILL REQUIRE REVISIONS TO ANY CORRESPONDING PLANS TO AVOID CONFLICTS BETWEEN PLANS. 1.DUMPSTERS AND TRASH COMPACTORS SHALL BE SCREENED IN ACCORDANCE WITH THE ZONING ORDINANCE. 2.OPEN STORAGE, WHERE PERMITTED, SHALL BE SCREENED IN ACCORDANCE WITH THE ZONING ORDINANCE. 3.OUTDOOR LIGHTING SHALL COMPLY WITH THE LIGHTING AND GLARE STANDARDS CONTAINED WITHIN THE ZONING ORDINANCE AND SUBDIVISION REGULATION ORDINANCE. 4.LANDSCAPING SHALL CONFORM TO LANDSCAPE PLANS APPROVED BY THE TOWN. 5.ALL ELEVATIONS SHALL COMPLY WITH THE STANDARDS CONTAINED WITHIN THE ZONING ORDINANCE. 6.BUILDINGS OF 5,000 SQUARE FEET OR GREATER SHALL BE 100% FIRE SPRINKLED. ALTERNATIVE FIRE PROTECTION MEASURES MAY BE APPROVED BY THE FIRE DEPARTMENT. 7.FIRE LANES SHALL BE DESIGNED AND CONSTRUCTED PER TOWN STANDARDS OR AS DIRECTED BY THE FIRE DEPARTMENT 8.TWO POINTS OF ACCESS SHALL BE MAINTAINED FOR THE PROPERTY AT ALL TIMES. 9.SPEED BUMPS/HUMPS ARE NOT PERMITTED WITHIN A FIRE LANE. 10. HANDICAPPED PARKING AREAS AND BUILDING ACCESSIBILITY SHALL CONFORM TO THE AMERICANS WITH DISABILITIES ACT (ADA) AND WITH THE REQUIREMENTS OF THE CURRENT, ADOPTED BUILDING CODE. 11. ALL SIGNAGE IS SUBJECT TO BUILDING OFFICIAL APPROVAL. 12. ALL FENCES AND RETAINING WALLS SHALL BE SHOWN ON THE SITE PLAN AND ARE SUBJECT TO BUILDING OFFICIAL APPROVAL. ALL FENCES AND RETAINING WALLS SHALL BE CONSTRUCTED TO MATCH BUILDING. 13. ALL EXTERIOR BUILDING MATERIALS ARE SUBJECT TO BUILDING OFFICIAL APPROVAL AND SHALL CONFORM TO THE APPROVED FAÇADE PLAN. 14. SIDEWALKS OF NOT LESS THAN SIX (6’) FEET IN WIDTH ALONG THOROUGHFARES AND COLLECTORS AND FIVE (5’) IN WIDTH ALONG RESIDENTIAL STREETS, AND BARRIER FREE RAMPS AT ALL CURB CROSSINGS SHALL BE PROVIDED PER TOWN STANDARDS. 15. APPROVAL OF THE SITE PLAN IS NOT FINAL UNTIL ALL ENGINEERING PLANS ARE APPROVED BY THE TOWN ENGINEER. 16. SITE PLAN APPROVAL IS REQUIRED PRIOR TO GRADING RELEASE. 17. ALL NEW ELECTRICAL LINES SHALL BE INSTALLED AND/OR RELOCATED UNDERGROUND. 18. ALL MECHANICAL EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW IN ACCORDANCE WITH THE ZONING ORDINANCE. 19. TWO POINTS OF ACCESS SHALL BE MAINTAINED FOR THE PROPERTY AT ALL TIMES. 20. ALL LANDSCAPE EASEMENTS MUST BE EXCLUSIVE OF ANY OTHER TYPE OF EASEMENT. 21. IMPACT FEE WILL BE ASSESSED IN ACCORDANCE WITH THE LAND USE CLASSIFICATION(S) IDENTIFIED ON THE SITE DATA SUMMARY TABLE; HOWEVER, CHANGES TO THE PROPOSED LAND USE AT THE TIME OF CO AND/OR FINISH. OUT PERMIT MAY RESULT IN ADDITIONAL IMPACT FEES AND/OR PARKING REQUIREMENTS. 1. NO FLOODPLAIN EXISTS ON THE SITE. 2. ALL DIMENSIONS ARE SHOWN TO FACE OF CURB UNLESS OTHERWISE NOTED. 3. FIRE LANES SHALL BE A MINIMUM OF 24' IN WIDTH WITH A 30' TURNING RADIUS. 4. FDCS SHALL BE PROVIDED IN ACCORDANCE WITH THE TOWN OF PROSPER STANDARDS. 5. TREES SHALL NOT BE LOCATED WITHIN PUBLIC EASEMENTS IN ACCORDANCE WITH TOWN STANDARDS. ORNAMENTAL TREES MAY BE LOCATED WITHIN THE 20' WATER EASEMENT (LOCATED ALONG THE NORTH SIDE OF THE 75' CITY OF IRVING EASEMENT) NO CLOSER THAN FOUR FEET (4') TO THE WATER LINE AND REQUIRING INSTALLATION OF A ROOT BARRIER. 6. FOUNDATION PLANTINGS TO BE PROVIDED IN ACCORDANCE WITH THE ZONING ORDINANCE. 7. NO TREES EXIST ON SITE. 8. DETENTION FOR THIS SITE IS PROVIDED ON BLOCK A, LOT 1. 9. IF OUTSIDE DISPLAY IS NEEDED OR REQUIRED AN SUP IS REQUIRED. 10. ALL PARKING SHALL BE WITHIN 350' OF THE BUILDING'S PUBLIC ENTRANCE. NOTES TOWN OF PROSPER SITE PLAN NOTES ENGINEER / SURVEYOR/ APPLICANT KIMLEY-HORN AND ASSOCIATES, INC. 5750 GENESIS COURT, SUITE 200 FRISCO, TX. 75034 PHONE (972) 335-3580 FAX (972) 335-3779 CONTACT: CHRISTOPHER LEPPERT, P.E. OWNER 380 & 289, LP 8000 WARREN PARKWAY FRISCO, TX. 75034 PHONE (972) 543-2412 CONTACT: SCOTT SHIP THE GATES OF PROSPER BLOCK A, LOT 4 CASE # D16-0051 13.369 ACRES BEN RENNISON SURVEY, ABSTRACT NO. 755 TOWN OF PROSPER, COLLIN COUNTY, TEXAS PREPARATION DATE: JUNE 02, 2016 SITE PLAN DEVELOPER BLUE STAR LAND 8000 WARREN PARKWAY FRISCO, TX 75034 PHONE (972) 543-2412 CONTACT: SCOTT SHIP N.T.S.VICINITY MAP SITE US HWY 380 (UNIVERSITY)STATEHWY289(PRESTON)DALLASPKWYBUS.289(COLEMAN)FIRST ST LACIMATOWN OF PROSPER CITY OF FRISCO LEGEND PROPERTY LINE RICHLAND LOVERSLNPROPOSED FIRE HYDRANT (FH) PROPOSED SEWER MANHOLE (MH) PROPOSED FIRE DEPT. CONNECTION (FDC) PROPOSED FIRE LANE / FIRE ACCESS, DRAINAGE, AND UTILITY EASEMENT (F.A.D.U.E.) PROPOSED CONTOUR I.D. WATER METER SCHEDULE TYPE SIZE NO.SAN. SEW. 1 DOMESTIC 2"1 1-6" 2 2"1 REMARKS PROPOSED PROPOSED1-6"DOMESTIC 06/07/2016 P&Z Conditional Approval @ 824@824 45' - 0" SIGN METAL ACCENT SIGN CORNICE GL-1 WD-56 WD-56WD-57 ST-1ST-1 MT-55 ST-1CMU-1 BRK-1CTC-2 CTC-1 CORNICE P-51 WD-55 8' - 0"MT-63 COPING MT-63 COPING MT-63 WD-55 CTC-1 T/ TILT-UP PANEL 25' - 0" . 45' - 0" GL-2 GL-2 20' - 8"ST-1ST-1 WD-56. Curbs Plus, Inc. RTU SCREEN. 26 GAUGE STEEL w/ SmartKote Cool Coating in 'SURREY BEIGE'15' - 0"15' - 0"13' - 9"13' - 9"3' - 5"3' - 3"3' - 3"3' - 4"Curbs Plus, Inc. RTU SCREEN. 26 GAUGE STEEL w/ SmartKote Cool Coating in 'SURREY BEIGE' Curbs Plus, Inc. RTU SCREEN. 26 GAUGE STEEL w/ SmartKote Cool Coating in 'SURREY BEIGE' Curbs Plus, Inc. RTU SCREEN. 26 GAUGE STEEL w/ SmartKote Cool Coating in 'SURREY BEIGE' 45' - 0" CORNICE WD-56 ST-1ST-1 MT-55 CTC-3CTC-3 17' - 0"8' - 0"MT-63 COPING ST-1ST-1 ST-1ST-1 MT-63 T/ TILT-UP PANEL 25' - 0" T/ TILT-UP PANEL 27' - 0" 13' - 9" 13' - 9"3' - 0"1' - 3"Curbs Plus, Inc. RTU SCREEN. 26 GAUGE STEEL w/ SmartKote Cool Coating in 'SURREY BEIGE' Curbs Plus, Inc. RTU SCREEN. 26 GAUGE STEEL w/ SmartKote Cool Coating in 'SURREY BEIGE' CTC-3 3' - 11"37' - 1 1/2"15' - 1 1/2"8' - 3"2' - 6"6' - 0"41' - 0"6' - 0"2' - 6"46' - 4"15' - 10"13' - 9"4' - 0"4' - 0"23' - 2 1/2"4' - 0"23' - 2"4' - 0"13' - 8"4' - 8"49' - 5"4' - 8"13' - 8"4' - 0"25' - 5"4' - 0"25' - 5 1/2"4' - 0"4' - 10"1' - 2"TYP.1' - 6"4' - 0"64' - 5"58' - 0"79' - 11"72' - 1"58' - 9"75' - 3" 201' - 0"206' - 0" 24' - 10"4' - 0"25' - 9 1/2"4' - 0"26' - 6 1/2"4' - 0"26' - 6 1/2"4' - 0"26' - 6 1/2"4' - 0"26' - 6 1/2"4' - 0"26' - 6 1/2"4' - 0"26' - 0"4' - 0"4' - 0"3' - 11"TYP.1' - 2"26' - 0" 2 3 4 1 26' - 0"213' - 10"407' - 0" www.FRCH.com 311 Elm Street | Suite 600 | Cincinnati, OH 45202 Telephone 513.241.3000 | Facsimile 513.241.5015 Contact Information Sheet Issue Information Sheet Information © 2012 This drawing, printed or otherwise, is the copyrighted property of FRCH Design Worldwide and FRCH/Architecture, Inc., P.C. The drawing may not be used, reproduced or copied without the permission of FRCH Design Worldwide or FRCH/Architecture, Inc., P.C.Title Drawn By: Issued Architecture p: (513) 241-3000 Owner p: (724) 273-3400 Dick's Sporting Goods 345 Court Street Coraopolis, PA 15108 FRCH Architecture Inc. 311 Elm Street, Suite 600 Cincinnati, OH 45202 Project No. Interior Design p: (513) 241-3000 FRCH Design Worldwide 311 Elm Street, Suite 600 Cincinnati, OH 45202 FRCH/Architecture, Inc., P.C.GATES OF PROSPER700 Richland BoulevardProsper, TX 7507833279.000 / #4622 EXTERIOR ELEVATIONS A. FUGAZZI 003a BRK-1 REFER TO SPECIFICATION SECTION 04200 FOR ACCEPTABLE MANUFACTURERS. MORTAR - ARGOS #127 ST-1 MANUFACTURER: CENTURIAN STONE - PATTERN #040 PALOS VERDE - COLOR: #786 ASPEN. GL-1 AMBER COLORED GLASS GL-2 CLEAR GLASS w/ GRAPHIC IMAGE WD-55 MANUFACTURER: ARRIGONI WOODS - RECLAIMED MATERIAL SUNBURNT SIDING - FINISH: NATURAL WD-56 MANUFACTURER: ARRIGONI WOODS - RECLAIMED MATERIAL SUNBURNT SIDING - FINISH: STAINED WD-57 MANUFACTURER: WESTERN WOOD PRODUCTS ASSOCIATION - 2x8 QTR LOG CABIN SIDING w/ REVEAL; PERMA-CHINK-BEIGE #216 - FINISH: STAINED MT-55 MANUFACTURER: INNOVATIVE POWDER COATINGS - PRODUCT: TRANS BLACK G50 MT-63 METAL ACM/COPING - COLOR: HARTFORD GREEN CMU-1 SMOOTH-FACE CENTER SCORED MASONRY UNIT. STAIN TO MATCH SW 0028 CAEN STONE CTC-1 CONCRETE TILT-UP WALL w/ TEXTURED COATING. COLOR TO MATCH SW 0028 CAEN STONE CTC-2 CONCRETE TILT-UP WALL w/ SMOOTH COATING. COLOR TO MATCH P-52 DSG BELDON CTC-3 CONCRETE TILT-UP WALL w/ TEXTURED COATING. COLOR TO MATCH BENJAMIN MOORE HC-124 CALDWELL GREEN P-124 MANUFACTURER:SHERWIN WILLIAMS - COLOR: TO MATCH DUNN EDWARDS DE6399 MOLASSES LRV 7 - FINISH: SATIN P-152 MANUFACTURER: SHERWIN WILLIAMS - COLOR: FS CUSTOM ORANGE PMS 158C FINISH SCHEDULE PRIMARY MATERIALS ST-1 = 2,215 sq. ft.21% CTC-1 = 2,845 sq. ft.27% BRK-1 = 945 sq. ft.9% SECONDARY MATERIALS WD-55 = 695 sq. ft.7% WD-56 = 765 sq. ft.7% WD-57 = 1,080 sq. ft. 10% GL-1 = 375 sq. ft. 4% GL-2 = 310 sq. ft.3% MT-55 = 125 sq. ft. 1% MT-63 = 1,200 sq. ft. 11% 1. NORTH (FRONT) ELEVATION TOTAL ELEVATION AREA = 11,935 sq. ft. WINDOWS AND DOORS AREA = 1,380 sq. ft. NET ELEVATION AREA = 10,555 sq. ft. PRIMARY MATERIALS ST-1 = 1,815 sq. ft. 36% CTC-3 = 2,960 sq. ft. 58% SECONDARY MATERIALS WD-56 = 195 sq. ft. 4% MT-55 = 110 sq. ft. 2% 2. EAST (SIDE) ELEVATION TOTAL ELEVATION AREA = 5,225 sq. ft. WINDOWS AND DOORS AREA = 145 sq. ft. NET ELEVATION AREA = 5,080 sq. ft. # Description Date 1 PERMIT/BID 10.10.2016 12 Alternate Facade Application 05.31.2017 SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" • “This Facade Plan is for conceptual purposes only. All building plans require review and approval from the Building Inspection Department” • "All mechanical equipment shall be screened from public view in accordance with the Zoning Ordinance" • “When permitted, exposed utility boxes and conduits shall be painted to match the building” • "All signage areas and locations are subject to approval by the Building Inspections Department" • “Windows shall have a maximum exterior visible reflectivity of ten (10) percent.” • “Entrance elements above 25' height are non-habitable elements integral to the building design.” FACADE PLAN CHECKLIST NKEY PLAN REF.REF.VENDINGMACHINEVENDINGMACHINEST-1CMU-1BRK-1 CTC-2 CTC-1 CORNICE P-51 CTC-1 CORNICE P-51 MT-55 MT-63 COPING Curbs Plus, Inc. RTU SCREEN. 26 GAUGE STEEL w/ SmartKote Cool Coating in 'SURREY BEIGE'3' - 5"14' - 10" 15' - 2"1' - 7"Curbs Plus, Inc. RTU SCREEN. 26 GAUGE STEEL w/ SmartKote Cool Coating in 'SURREY BEIGE'8' - 0"17' - 0"T/ TILT-UP PANEL 25' - 0" T/ TILT-UP PANEL 27' - 0" 40' - 0"112' - 6"80' - 0" 158' - 0"4' - 0"4' - 0"1' - 2"26' - 0"4' - 0"1' - 2"LOADING DOCK COMPACTOR 4' - 0"25' - 11"4' - 0"26' - 0"4' - 0"26' - 0"4' - 0"26' - 0"4' - 0"11' - 3" 4' - 0"36' - 0"4' - 0"48' - 3"22' - 8"4' - 0"22' - 8"4' - 0"22' - 8"4' - 0"26' - 0"4' - 0"4' - 0"48' - 3"4' - 0"4' - 0"4' - 0"25' - 9 1/2"4' - 0"26' - 6 1/2"4' - 0"26' - 6 1/2"4' - 0"26' - 6 1/2"4' - 0"26' - 6 1/2"4' - 0"26' - 6 1/2"4' - 0"26' - 0"4' - 0"4' - 0"214' - 0"26' - 0" 2 3 4 1 407' - 0"26' - 0"213' - 10"T/ TILT-UP PANEL 27' - 0"P-152 ST-1 MT-55 CTC-3 ST-1CTC-3 CTC-3 P-124 MT-63CTC-1 BRK-1CMU-1CTC-1BRK-1 BRK-1 CTC-1 MT-63P-51 ST-1 T/ TILT-UP PANEL 25' - 0"14' - 0"14' - 0"8' - 0"17' - 0"WD-56. CORNICE CORNICE COPING COPING ST-1 SIGN SIGNORANGE PAINT Curbs Plus, Inc. RTU SCREEN. 26 GAUGE STEEL w/ SmartKote Cool Coating in 'SURREY BEIGE' 13' - 9"1' - 3"Curbs Plus, Inc. RTU SCREEN. 26 GAUGE STEEL w/ SmartKote Cool Coating in 'SURREY BEIGE' 15' - 0"1' - 4"www.FRCH.com 311 Elm Street | Suite 600 | Cincinnati, OH 45202 Telephone 513.241.3000 | Facsimile 513.241.5015 Contact Information Sheet Issue Information Sheet Information © 2012 This drawing, printed or otherwise, is the copyrighted property of FRCH Design Worldwide and FRCH/Architecture, Inc., P.C. The drawing may not be used, reproduced or copied without the permission of FRCH Design Worldwide or FRCH/Architecture, Inc., P.C.Title Drawn By: Issued Architecture p: (513) 241-3000 Owner p: (724) 273-3400 Dick's Sporting Goods 345 Court Street Coraopolis, PA 15108 FRCH Architecture Inc. 311 Elm Street, Suite 600 Cincinnati, OH 45202 Project No. Interior Design p: (513) 241-3000 FRCH Design Worldwide 311 Elm Street, Suite 600 Cincinnati, OH 45202 FRCH/Architecture, Inc., P.C.GATES OF PROSPER700 Richland BoulevardProsper, TX 7507833279.000 / #4622 EXTERIOR ELEVATIONS A. FUGAZZI 003b 4. WEST (SIDE) ELEVATION BRK-1 REFER TO SPECIFICATION SECTION 04200 FOR ACCEPTABLE MANUFACTURERS. MORTAR - ARGOS #127 ST-1 MANUFACTURER: CENTURIAN STONE - PATTERN #040 PALOS VERDE - COLOR: #786 ASPEN. GL-1 AMBER COLORED GLASS GL-2 CLEAR GLASS w/ GRAPHIC IMAGE WD-55 MANUFACTURER: ARRIGONI WOODS - RECLAIMED MATERIAL SUNBURNT SIDING - FINISH: NATURAL WD-56 MANUFACTURER: ARRIGONI WOODS - RECLAIMED MATERIAL SUNBURNT SIDING - FINISH: STAINED WD-57 MANUFACTURER: WESTERN WOOD PRODUCTS ASSOCIATION - 2x8 QTR LOG CABIN SIDING w/ REVEAL; PERMA-CHINK-BEIGE #216 - FINISH: STAINED MT-55 MANUFACTURER: INNOVATIVE POWDER COATINGS - PRODUCT: TRANS BLACK G50 MT-63 METAL ACM/COPING - COLOR: HARTFORD GREEN CMU-1 SMOOTH-FACE CENTER SCORED MASONRY UNIT. STAIN TO MATCH SW 0028 CAEN STONE CTC-1 CONCRETE TILT-UP WALL w/ TEXTURED COATING. COLOR TO MATCH SW 0028 CAEN STONE CTC-2 CONCRETE TILT-UP WALL w/ SMOOTH COATING. COLOR TO MATCH P-52 DSG BELDON CTC-3 CONCRETE TILT-UP WALL w/ TEXTURED COATING. COLOR TO MATCH BENJAMIN MOORE HC-124 CALDWELL GREEN P-124 MANUFACTURER:SHERWIN WILLIAMS - COLOR: TO MATCH DUNN EDWARDS DE6399 MOLASSES LRV 7 - FINISH: SATIN P-152 MANUFACTURER: SHERWIN WILLIAMS - COLOR: FS CUSTOM ORANGE PMS 158C FINISH SCHEDULE PRIMARY MATERIALS ST-1 = 3,315 sq. ft.33% CTC-1 = 2,830 sq. ft. 28% CTC-3 = 3,700 sq. ft. 37% SECONDARY MATERIALS MT-55 = 200 sq. ft.2% 3. SOUTH (REAR) ELEVATION TOTAL ELEVATION AREA = 10,045 sq. ft. WINDOWS AND DOORS AREA = 0 sq. ft. NET ELEVATION AREA = 10,045 sq. ft. NKEY PLAN # Description Date 1 PERMIT/BID 10.10.2016 12 Alternate Facade Application 05.31.2017 SCALE: 1/16" = 1'-0" • “This Facade Plan is for conceptual purposes only. All building plans require review and approval from the Building Inspection Department” • "All mechanical equipment shall be screened from public view in accordance with the Zoning Ordinance" • “When permitted, exposed utility boxes and conduits shall be painted to match the building” • "All signage areas and locations are subject to approval by the Building Inspections Department" • “Windows shall have a maximum exterior visible reflectivity of ten (10) percent.” • “Entrance elements above 25' height are non-habitable elements integral to the building design.” FACADE PLAN CHECKLIST SCALE: 1/16" = 1'-0" PRIMARY MATERIALS ST-1 = 1,195 sq. ft.24% CTC-1 = 3,014 sq. ft. 58% BRK-1 = 842 sq. ft. 16% SECONDARY MATERIALS MT-55 = 108 sq. ft.2% TOTAL ELEVATION AREA = 5,175 sq. ft. WINDOWS AND DOORS AREA = 16 sq. ft. NET ELEVATION AREA = 5,159 sq. ft. Regal White Ɨ IR .72 SRI 88 Surrey Beige Ɨ IR .48 SRI 53 Dark Bronze Ɨ IR .31 SRI 32 Evergreen Ɨ IR .31 SRI 31 Warm White Ɨ IR .62 SRI 73 Slate Gray Ɨ IR .36 SRI 37 Terra Cotta Ɨ IR .35 SRI 35 Royal Blue Ɨ IR .30 SRI 31 All standard SmartKote® colors have an available 25-year or an optional 35-year finish warranty. Colors shown closely approximate actual coating colors. These colors utilize Cool Coating Technology. Cool Coatings (PVDF) SmartKote coatings feature fade-resistant color, incredible durability and environmentally friendly “cool” technology. Standard Regal Warm Surrey Slate Dark Terra Ever- Royal Bare Aluminum Panel Type Gauges White White Beige Gray Bronze Cotta green Blue Aluminum Zinc Coated Zinc Coated + Acrylic Long Span III Wall 26 Ga. X X X X X X X X X Long Span III Roof 26 Ga. X X X X X X X X X Architectural III 26 Ga. X X X X X X X X X Architectural “V” Rib 26 Ga. X X X X X X X X X 16” Seam-Loc Roof 24 Ga. X X X X X X X X X 16” Loc-Seam Roof 24 Ga. X X X X X X X X X Shadow Panel Wall 24 Ga. X X X X X X Soffit Liner 24 Ga. X X X X X X X X Standing Seam II 24 Ga. X X X X Standing Seam 360 24 Ga. X X X X SMARTKOTE STANDARD COLOR AVAILABILITY Form #00337 American Buildings Company Marketing Information Line 888.307.4338 www.americanbuildingscompany.com ABC – Atlantic Division 501 Golden Eagle Drive LaCrosse, VA 23950 Tel: 706.562.8020 Fax 706.562.8017 ABC – South Division 1150 State Docks Road Eufaula, AL 36027 Tel: 334.688.2032 Fax: 334.688.2185 ABC – Midwest Division 901 W. Main Street El Paso, IL 61738 Tel: 309.527.1500 Fax: 309.527.1522 ABC - West Division 2260 Tenaya Drive Modesto, CA 95354 Tel: 209.236.0580 Fax: 209.236.0588 To be considered “cool,” products must have a Solar Reflectance of at least .25. Solar Reflectance is the fraction of the total solar energy that is reflected away from a surface. Solar Reflectance Solar Reflectance, Thermal Emittance and Solar Reflectance Index (SRI) PRODUCT SPECIFICATIONS Thermal Emittance Thermal Emittance is the measure of a panel’s ability to release heat that it has absorbed. Solar Reflectance Index (SRI) Put Solar Reflectance and Thermal Emittance together and you get the Solar Reflective Index (SRI). SRI is calculated by using the values of solar reflectance, thermal emittance and a medium wind coefficient. The higher the SRI value, the lower its surface temperature and conse- quently, the heat gain into the building. Cool metal roofs coated with the SmartKote COOL-pigmented PVDF resin achieve an SRI of 31-88, depending on the color. Conventional roof surfaces have low reflectance (0.05 to 0.25) and high thermal emittance (typically over .85). Roof panels with both high reflectance and high emittance can reduce the surface tempera- ture by as much as 30-50% based on color and geographic location, which will result in a reduced heat gain to the building, therefore reducing the energy demand. SMARTKOTE PVDF TECHNICAL INFORMATION TEST TEST METHODS PERFORMANCE Dry Film Thickness Specular Gloss Dry Film Hardness Film Adhesion - Dry, wet, boiling water Formability Abrasion Resistance - Falling Sand - Gardner Scratch - Taber Abrasion Chemical & Detergent Resistance Salt Spray Resistance Humidity Resistance South Florida Weathering - Color Retention - Crack Resistance ASTM D 5796 Primer ASTM D 1005 ASTM D523 ASTM D3363 ASTM D3359 ASTM D4145 ASTM D968 ASTM D2197 ASTM D4060 ASTM D1308 ASTM B117 ASTM D2247 D2244 D4214 0.3 mils minimum Topcoat 0.7 mils system (+/-.05) Backer 0.5 mils system (+/-.05) Low gloss, 5 – 12% @ 60 HB minimum Excellent, no removal 2 T Bend – no removal Exceeds 65 liters/mil 250 – 300 grams load C.S. 10 wheel/20 mg loss/100 cycles Excellent, no attack Passes 1,000 hours, Galvalume Passes 1,000 hours HDG/Galvalume <5dE change after 35 years >8 chalk rating SMARTKOTE PANEL COLORS SOLAR SMARTKOTE INITIAL SOLAR INITIAL THERMAL REFLECTIVE COLOR REFLECTANCE (IR) EMITTANCE (IE) INDEX (SRI) Regal White .72 0.85 88 Warm White .62 0.84 73 Surrey Beige .48 0.83 53 Slate Gray .36 0.83 37 Dark Bronze .31 0.87 32 Terra Cotta .35 0.84 35 Evergreen .31 0.85 31 Royal Blue .30 0.86 31 Bare Aluminum .77 0.08 72 Zinc Coated 311 ELM STREET, SUITE 600 CINCINNATI OH 45202 513.241.3000 FAX 513.241.5015 05/22/2017 Mr. Alex Gushko, AICP Senior Planner Development Services Town of Prosper, TX Re: Dicks Sporting Goods / Field & Stream - Gates of Prosper Alternate Façade Application Dear Mr. Gushko, This letter is to support the Alternate Façade Application for the previously approved façade design for the Dicks Sporting Goods /Field & Stream retail building at the Gates of Prosper development. This application is for the addition of RTU screens on the rooftop of the current store under construction. Per your email on 5/8/17 and phone conversation on 5/9/17 – notification was made stating that portions of the installed RTU’s are visible from certain vantage points surrounding the site. The approved façade design noted that the RTU’s would not be visible from public view. The approved façade design included a parapet wall height around all sides of the building to screen public view per the requirement for site lines based on a viewing height of 6’-0” above grade. The “visible” RTU’s being questioned, are visible from surrounding vantage points on the site at approx. 16’-0”+ above grade due to the surrounding topography of the site and roadways. This has created an additional 10’ of viewing height that was not part of the previous approved design criteria. Due to the site conditions and topography heights, we are proposing to screen the RTU’s per the enclosed specification. This product has been approved and used on other Dicks Sporting Goods stores within Florida and California in municipalities with similar design guidelines. The colors and materials are harmonious with the current façade design and provide the required screening from public view. We believe this solution meets the screening criteria and alleviates the concern for visibility of the RTU’s on the building. Please review all enclosed information for approval of this application. If you have any questions or if anything is missing, please feel free to contact me directly at 513-362-3325 or afugazzi@frch.com. Sincerely, Annie Fugazzi Senior Professional + Project Manager FRCH Design Worldwide Page 1 of 2 To: Planning & Zoning Commission From: Scott Ingalls, AICP, Planner Through: Alex Glushko, AICP, Senior Planner Re: Planning & Zoning Commission Meeting – June 6, 2017 Agenda Item: Consider and act upon a request for a Façade Exception for Bryant’s Addition, Block 23, Lot 3R (307 E. First Street), located on the northwest corner of Church Street and First Street. (MD17- 0004). Description of Agenda Item: The applicant is seeking a Façade Exception for a 4,550 square foot office building to allow for the use of an alternative material (DecoStone) to meet the masonry requirements. Staff approved the façade plan (Attachment 2) for the proposed office building on January 19, 2017. The approved façade plan calls for a combination of stone and Hardie siding to comply with the masonry requirements of the Downtown Office (DTO) zoning district. The DTO District permits a maximum of 90% of the structure to be clad with cementatious fiber board, with the remaining portion of the façade to be clad in stone. As depicted on Attachment 3, the applicant is proposing to use a decorative limestone plaster that is applied to a lath system and then hand troweled to create the appearance of individual stones and mortar joints. The proposed material will be applied to 25% of the north and south elevations and 21% of the east and west elevations. Attachment 4 provides product information about the proposed alternative material. In Attachment 5, the applicant indicates that the purpose of request to use of the alternative material instead of stone is: • aesthetically pleasing, • maintenance free, and • speeds up the masonry construction process. In considering an exception to the required masonry requirements, the Planning & Zoning Commission and Town Council may consider whether a proposed alternate material: (a) is a unique architectural expression; (b) includes unique building styles and materials; (c) is consistent with high quality development; (d) is or would be visually harmoniousness with existing or proposed nearby buildings; Prosper is a place where everyone matters. PLANNING Page 2 of 2 (e) has obvious merit based upon the quality and durability of the materials; and (f) represents an exterior building material that is in keeping with the intent of this chapter to balance the above-mentioned objectives. Attachments: 1. Location Map 2. Staff Approved Façade Plan 3. Proposed Facade Plan 4. Plaster Product Information 5. Criteria Response Letter Town Staff Recommendation: Town staff recommends that the Planning & Zoning Commission consider and act upon a request for a façade exception for 307 E. First Street. Town Council Consideration: Upon a recommendation by the Planning & Zoning Commission, this request will be scheduled for the Town Council meeting on June 27, 2017. MD17-0004 FI RST ST SECO ND ST CHURCH ST±0 40 80 12020Feet NWC E. 1st STREET & CHURCH STOFFICE BUILDINGLOTS 3,4,5 AND 6 - BLOCK 23, BRYANTS ADDITION TO PROSPERPROSPER, TEXASADB JBW 12/20/2016 AS NOTED RA16-018PRELIMINARYFOR REVIEWFILE DWG NO. SHEETSOF SHEET JOB NO. SCALE CHECKED DATE DRAWN REVISIONS BY AT TS XETEFO SAREGISTER E D ARC H I T ECTJ.W A R 8 DL AB.W3 142 A401 OWNER BROWN & GRIFFIN REAL ESTATE ADVISORS LP PO BOX 129 PROSPER, TX 75078 972-347-0572 APPLICANT CLAYMORE ENGINEERING TOTAL SURFACE AREA EAST ELEVATION GLAZING SURFACE AREA NET SURFACE AREA STONE AREA SIDING AREA - B HARDIE SIDING TRIM AND FACIA AREA 704 SQ FT 75 SQ FT 629 SQ FT 130 SQ FT 21 % OF NET 68 % OF NET 11 % OF NET 428 SQ FT 71 SQ FT TOTAL SURFACE AREA GLAZING SURFACE AREA NET SURFACE AREA STONE AREA SIDING AREA - B HARDIE SIDING TRIM AND FACIA AREA 1800 SQ FT 240 SQ FT 1560 SQ FT 392 SQ FT 25 % OF NET 56.0 % OF NET 10 % OF NET 874 SQ FT 173 SQ FT SIDING AREA - F HARDIE SIDING 9 % OF NET121 SQ FT SOUTH ELEVATION FACADE PLAN STANDARD NOTES •This Facade Plan is for conceptual purposes only. All building plans require review and approval from the Building Inspections Department • All mechanical equipment shall be screened from public view in accor- dance with the Zoning Ordinance •When permitted, exposed utility boxes and conduits shall be painted to match the building • All signage areas and locations are subject to approval by the Building Inspections Department •Windows shall have a maximum exterior visible reflectivity of ten (10) percent. 1903 CENTRAL DRIVE #406 BEDFORD, TX 76021 817-281-0572 SOUTH ELEVATION LOOKING NORTH (FRONT) 3/16” = 1’0”1 EAST ELEVATION LOOKING WEST 3/16” = 1’0”2 AC 1 2 N AC EAST FIRST STREET EAST SECOND STREET CHURCH STREET10'-0"12'-0"12 8 12 812 8 138’ A - CHARCOAL SHINGLE DORMER C - HARDIE TRIM C - HARDIE TRIM B - HARDIE SIDING F - HARDIE SHINGLE D - STONE C - HARDIE TRIM A - CHARCOAL SHINGLE DORMER C - HARDIE TRIM C - HARDIE TRIM B - HARDIE SIDING F - HARDIE SHINGLE D - STONE C - HARDIE TRIM 10'-0"12'-0"12 4 A - CHARCOAL SHINGLE DORMER C - HARDIE TRIM C - HARDIE TRIM C - HARDIE SIDING B - HARDIE SIDING D - STONE MTL RAILING 34’ 01/19/2017 ADB JBW 12/20/2016 AS NOTED RA16-018PRELIMINARYFOR REVIEWFILE DWG NO. SHEETSOF SHEET JOB NO. SCALE CHECKED DATE DRAWN REVISIONS BY NWC E. 1st STREET & CHURCH STOFFICE BUILDINGLOTS 3,4,5 AND 6 - BLOCK 23, BRYANTS ADDITION TO PROSPERPROSPER, TEXASAT TS XETEFO SAREGISTER E D ARC H I T ECTJ.W A R 8 DL AB.W3 142 A402 704 SQ FT 629 SQ FT SIDING AREA - F HARDIE SIDING 9 % OF NET138 SQ FT FACADE PLAN STANDARD NOTES •This Facade Plan is for conceptual purposes only. All building plans require review and approval from the Building Inspections Department • All mechanical equipment shall be screened from public view in accor- dance with the Zoning Ordinance •When permitted, exposed utility boxes and conduits shall be painted to match the building • All signage areas and locations are subject to approval by the Building Inspections Department •Windows shall have a maximum exterior visible reflectivity of ten (10) percent. OWNER BROWN & GRIFFIN REAL ESTATE ADVISORS LP PO BOX 129 PROSPER, TX 75078 972-347-0572 APPLICANT CLAYMORE ENGINEERING 1903 CENTRAL DRIVE #406 BEDFORD, TX 76021 817-281-0572 TOTAL SURFACE AREA GLAZING SURFACE AREA NET SURFACE AREA STONE AREA SIDING AREA - B HARDIE SIDING TRIM AND FACIA AREA 1790 SQ FT 220 SQ FT 1570 SQ FT 392 SQ FT 25 % OF NET 55 % OF NET 11 % OF NET 864 SQ FT 176 SQ FT NORTH ELEVATION NORTH ELEVATION LOOKING SOUTH 3/16” = 1’0”1 TOTAL SURFACE AREA WEST ELEVATION GLAZING SURFACE AREA NET SURFACE AREA STONE AREA SIDING AREA TRIM AND FACIA AREA 75 SQ FT 130 SQ FT 21 % OF NET 68 % OF NET 11 % OF NET 428 SQ FT 71 SQ FT WEST ELEVATION LOOKING EAST 3/16” = 1’0”2 AC 1 2 N AC EAST FIRST STREET EAST SECOND STREET CHURCH STREET10'-0"12'-0"12 8 12 812 8 138’ MTL RAILING BEHIND COLUMNS A - CHARCOAL SHINGLE DORMER C - HARDIE TRIM C - HARDIE TRIM B - HARDIE SIDING D - STONE C - HARDIE TRIM A - CHARCOAL SHINGLE DORMER C - HARDIE TRIM C - HARDIE TRIM B - HARDIE SIDING D - STONE C - HARDIE TRIM 10'-0"12'-0"12 4 B - HARDIE SIDING D - STONE C - HARDIE TRIM A - CHARCOAL SHINGLE DORMER C - HARDIE TRIM C - HARDIE SIDING MTL RAILING 34’ F - HARDIE SHINGLE F - HARDIE SHINGLE 01/19/2017 NWC E. 1st STREET & CHURCH STOFFICE BUILDINGLOTS 3,4,5 AND 6 - BLOCK 23, BRYANTS ADDITION TO PROSPERPROSPER, TEXASADB JBW 12/20/2016 AS NOTED RA16-018PRELIMINARYFOR REVIEWFILE DWG NO. SHEETSOF SHEET JOB NO. SCALE CHECKED DATE DRAWN REVISIONS BY AT TS XETEFO SAREGISTER E D ARC H I T ECTJ.W A R 8 DL AB.W3 142 A401 OWNER BROWN & GRIFFIN REAL ESTATE ADVISORS LP PO BOX 129 PROSPER, TX 75078 972-347-0572 APPLICANT CLAYMORE ENGINEERING TOTAL SURFACE AREA EAST ELEVATION GLAZING SURFACE AREA NET SURFACE AREA STONE AREA SIDING AREA - B HARDIE SIDING TRIM AND FACIA AREA 704 SQ FT 75 SQ FT 629 SQ FT 130 SQ FT 21 % OF NET 68 % OF NET 11 % OF NET 428 SQ FT 71 SQ FT TOTAL SURFACE AREA GLAZING SURFACE AREA NET SURFACE AREA STONE AREA SIDING AREA - B HARDIE SIDING TRIM AND FACIA AREA 1800 SQ FT 240 SQ FT 1560 SQ FT 392 SQ FT 25 % OF NET 56.0 % OF NET 10 % OF NET 874 SQ FT 173 SQ FT SIDING AREA - F HARDIE SIDING 9 % OF NET121 SQ FT SOUTH ELEVATION FACADE PLAN STANDARD NOTES •This Facade Plan is for conceptual purposes only. All building plans require review and approval from the Building Inspections Department • All mechanical equipment shall be screened from public view in accor- dance with the Zoning Ordinance •When permitted, exposed utility boxes and conduits shall be painted to match the building • All signage areas and locations are subject to approval by the Building Inspections Department •Windows shall have a maximum exterior visible reflectivity of ten (10) percent. 1903 CENTRAL DRIVE #406 BEDFORD, TX 76021 817-281-0572 SOUTH ELEVATION LOOKING NORTH (FRONT) 3/16” = 1’0”1 EAST ELEVATION LOOKING WEST 3/16” = 1’0”2 AC 1 2 N AC EAST FIRST STREET EAST SECOND STREET CHURCH STREET10'-0"12'-0"12 8 12 812 8 138’ A - CHARCOAL SHINGLE DORMER C - HARDIE TRIM C - HARDIE TRIM F - HARDIE SHINGLE B - HARDIE SIDING C - HARDIE TRIM D - DECOSTONE A - CHARCOAL SHINGLE DORMER C - HARDIE TRIM C - HARDIE TRIM F - HARDIE SHINGLE B - HARDIE SIDING C - HARDIE TRIM D - DECOSTONE 10'-0"12'-0"12 4 A - CHARCOAL SHINGLE DORMER C - HARDIE TRIM C - HARDIE TRIM C - HARDIE SIDING B - HARDIE SIDING D - DECOSTONE MTL RAILING 34’ 01/19/2017 ADB JBW 12/20/2016 AS NOTED RA16-018PRELIMINARYFOR REVIEWFILE DWG NO. SHEETSOF SHEET JOB NO. SCALE CHECKED DATE DRAWN REVISIONS BY NWC E. 1st STREET & CHURCH STOFFICE BUILDINGLOTS 3,4,5 AND 6 - BLOCK 23, BRYANTS ADDITION TO PROSPERPROSPER, TEXASAT TS XETEFO SAREGISTER E D ARC H I T ECTJ.W A R 8 DL AB.W3 142 A402 704 SQ FT 629 SQ FT SIDING AREA - F HARDIE SIDING 9 % OF NET138 SQ FT FACADE PLAN STANDARD NOTES •This Facade Plan is for conceptual purposes only. All building plans require review and approval from the Building Inspections Department • All mechanical equipment shall be screened from public view in accor- dance with the Zoning Ordinance •When permitted, exposed utility boxes and conduits shall be painted to match the building • All signage areas and locations are subject to approval by the Building Inspections Department •Windows shall have a maximum exterior visible reflectivity of ten (10) percent. OWNER BROWN & GRIFFIN REAL ESTATE ADVISORS LP PO BOX 129 PROSPER, TX 75078 972-347-0572 APPLICANT CLAYMORE ENGINEERING 1903 CENTRAL DRIVE #406 BEDFORD, TX 76021 817-281-0572 TOTAL SURFACE AREA GLAZING SURFACE AREA NET SURFACE AREA STONE AREA SIDING AREA - B HARDIE SIDING TRIM AND FACIA AREA 1790 SQ FT 220 SQ FT 1570 SQ FT 392 SQ FT 25 % OF NET 55 % OF NET 11 % OF NET 864 SQ FT 176 SQ FT NORTH ELEVATION NORTH ELEVATION LOOKING SOUTH 3/16” = 1’0”1 TOTAL SURFACE AREA WEST ELEVATION GLAZING SURFACE AREA NET SURFACE AREA STONE AREA SIDING AREA TRIM AND FACIA AREA 75 SQ FT 130 SQ FT 21 % OF NET 68 % OF NET 11 % OF NET 428 SQ FT 71 SQ FT WEST ELEVATION LOOKING EAST 3/16” = 1’0”2 AC 1 2 N AC EAST FIRST STREET EAST SECOND STREET CHURCH STREET10'-0"12'-0"12 8 12 812 8 138’ MTL RAILING BEHIND COLUMNS A - CHARCOAL SHINGLE DORMER C - HARDIE TRIM C - HARDIE TRIM B - HARDIE SIDING C - HARDIE TRIM D - DECOSTONE 10'-0"12'-0"12 4 B - HARDIE SIDING C - HARDIE TRIM D - DECOSTONE A - CHARCOAL SHINGLE DORMER C - HARDIE TRIM C - HARDIE SIDING MTL RAILING 34’ F - HARDIE SHINGLE A - CHARCOAL SHINGLE DORMER C - HARDIE TRIM C - HARDIE TRIM F - HARDIE SHINGLE B - HARDIE SIDING C - HARDIE TRIM D - DECOSTONE 01/19/2017 RESULTS Page 1 of 3 ] Prosper is a place where everyone matters. 1. Call to Order/Roll Call. 2. Invocation, Pledge of Allegiance and Pledge to the Texas Flag. 3. Presentations/Proclamations • Administer Oaths of Office and Present Certificates of Election to Curry Vogelsang, Jr., Place 3, and Jeff Hodges, Place 5, of the Prosper Town Council. (RB) • Presentation of Certificates of Appreciation to members of the 2016 Charter Review Commission. (RB) 4. Announcements of recent and upcoming events. 5. CONSENT AGENDA: All Consent Agenda Items, Approved, 7-0 (Items placed on the Consent Agenda are considered routine in nature and non- controversial. The Consent Agenda can be acted upon in one motion. Items may be removed from the Consent Agenda by the request of Council Members or staff.) 5a. Consider and act upon minutes from the following Town Council meeting. (RB) • Regular Meeting – May 9, 2017 • Special Meeting to Canvass Election – May 15, 2017 5b. Consider and act upon an ordinance approving negotiated settlement between the Atmos Cities Steering Committee and Atmos Energy Corporation regarding the Company’s 2017 rates set by the settlement and terminating the RRM process for pending renegotiation of RRM terms and conditions. (KN) 5c. Consider and act upon an ordinance amending Planned Development-66 (PD-66), on 902.6± acres, in order to modify the residential architectural requirements, generally located south of Prosper Trail, north of First Street, west of Dallas Parkway and east of Legacy Drive. (Z17-0003). (JW) 5d. Consider and act upon an ordinance amending Article 10.03, “Subdivision Ordinance,” of Chapter 10, “Subdivision Regulations,” of the Code of Ordinances by enacting a new Subdivision Ordinance. (JW) 5e. Consider and act upon approval of the Memorandum of Understanding between the City of Irving and the Town of Prosper relative to the construction of improvements and/or use of an existing City of Irving 75-foot water line easement generally located adjacent to and north of US 380 in the Town of Prosper. (PN) AGENDA Meeting of the Prosper Town Council Prosper Municipal Chambers 108 W. Broadway, Prosper, Texas Tuesday, May 23, 2017 6:00 p.m. RESULTS Page 2 of 3 5f. Consider and act upon whether to direct staff to submit a written notice of appeal on behalf of the Town Council to the Development Services Department, pursuant to Chapter 4, Section 1.5(C)(7) and 1.6(B)(7) of the Town’s Zoning Ordinance, regarding action taken by the Planning & Zoning Commission on any Site Plan or Preliminary Site Plan. (AG) 6. CITIZEN COMMENTS: The public is invited to address the Council on any topic. However, the Council is unable to discuss or take action on any topic not listed on this agenda. Please complete a “Public Meeting Appearance Card” and present it to the Town Secretary prior to the meeting. REGULAR AGENDA: If you wish to address the Council during the regular agenda portion of the meeting, please fill out a “Public Meeting Appearance Card” and present it to the Town Secretary prior to the meeting. Citizens wishing to address the Council for items listed as public hearings will be recognized by the Mayor. Those wishing to speak on a non-public hearing related item will be recognized on a case-by-case basis, at the discretion of the Mayor and Town Council. PUBLIC HEARING: 7. Presentation of service plan and first Public Hearing to consider the voluntary annexation of 5.7± acres located on the west side of Custer Road, 1,300± feet south of Frontier Parkway. (A17-0001). (JW) No action required DEPARTMENT ITEM: 8. Consider and act upon authorizing the Town Manager to execute a Development Agreement between CADG Prosper 28, LLC, and the Town of Prosper, Texas, related to the park fees for The Montclair development. (HW) Approved, 7-0 9. EXECUTIVE SESSION: Recess into Closed Session in compliance with Section 551.001 et seq. Texas Government Code, as authorized by the Texas Open Meetings Act, to deliberate regarding: 9a. Section 551.087 – To discuss and consider economic development incentives. 9b. Section 551.072 – To discuss and consider purchase, exchange, lease or value of real property for municipal purposes and all matters incident and related thereto. 9c. Section 551.071 – Consultation with the Town Attorney regarding legal issues associated with annexation and ETJ release agreements in Town ETJ areas, development issues associated with areas subject to annexation agreements and ETJ releases, and all matters incident and related thereto. 9d. Section 551.071 – Consultation with the Town Attorney regarding the Zoning Ordinance. RESULTS Page 3 of 3 9e. Section 551.074 – To discuss and consider election of Mayor Pro-Tem and Deputy Mayor Pro-Tem. 10. Reconvene in Regular Session and take any action necessary as a result of the Closed Session. 11. Possibly direct Town staff to schedule topic(s) for discussion at a future meeting. • Mobile App Update (LJ) • Discussion of City-County Plat Approval Agreement (HJ) • Discussion of Collin County Bond Election Resolution (HJ) • Discussion of Property Tax on Leased Vehicles (KN) • Discussion on Sign Regulations for Big Box Retail (JW) 12. Adjourn. CERTIFICATION I, the undersigned authority, do hereby certify that this Notice of Meeting was posted at Prosper Town Hall, located at 121 W. Broadway Street, Prosper, Texas 75078, a place convenient and readily accessible to the general public at all times, and said Notice was posted by 5:00 p.m., on May 19, 2017, and remained so posted at least 72 hours before said meeting was convened. _______________________________ _________________________ Carol Myers, Deputy Town Secretary Date Notice Removed Pursuant to Section 551.071 of the Texas Government Code, the Town Council reserves the right to consult in closed session with its attorney and to receive legal advice regarding any item listed on this agenda. NOTICE Pursuant to Town of Prosper Ordinance No. 13-63, all speakers other than Town of Prosper staff are limited to three (3) minutes per person, per item, which may be extended for an additional two (2) minutes with approval of a majority vote of the Town Council. NOTICE OF ASSISTANCE AT PUBLIC MEETINGS: The Prosper Town Council meetings are wheelchair accessible. For special services or assistance, please contact the Town Secretary’s Office at (972) 569- 1011 at least 48 hours prior to the meeting time.