Loading...
02.19.19 PZ Packet ] 1. Call to Order / Roll Call 2. Pledge of Allegiance. 3. CONSENT AGENDA (Items placed on the Consent Agenda are considered routine in nature and are considered non-controversial. The Consent Agenda can be acted upon in one motion. A Planning & Zoning Commissioner may remove any item for discussion and separate action. Planning & Zoning Commissioners may vote nay on any single item without comment and may submit written comments as part of the official record.) 3a. Consider and act upon minutes from the February 5, 2019, Planning & Zoning Commission Regular meeting. 3b. Consider and act upon a Site Plan for a Convenience Store and Restaurant with Gas Pumps (7-Eleven), on 1.4± acres, located on southwest corner of Preston Road and Frontier Parkway. The property is zoned Planned Development-10 (PD-10). (D18-0127). 3c. Consider and act upon a Final Plat for Victory at Frontier, Block A, Lot 2, on 1.4± acres, located on the southwest corner of Preston Road and Frontier Parkway. The property is zoned Planned Development-10 (PD-10). (D18-0128). 3d. Consider and act upon a Final Plat for Lakewood, Phase 2, Block A, Lots 1-7, 1X and 2X, and Block B, Lots 1-6, and 1X, for 13 single family residential lots and three (3) HOA/open space lots, on 3.6± acres, located on the east side of Lakewood Drive, north of US 380. The property is zoned Planned Development-87 (PD-87). (D18-0130). 3e. Consider and act upon a Final Plat for the Prosper School Church Addition, Block A, Lot 1, on 30.9± acres, located on the north side of Fishtrap Road, east of Teel Parkway. The property is zoned Agricultural (A). (D18-0132). 3f. Consider and act upon a Final Plat/Conveyance Plat for Sexton Farm and Ranch, Block A, Lots 1-3, on 58.9± acres, located on the north side of First Street, west of Coit Road. The property is zoned Agricultural (A). (D19-0010). 3g. Consider and act upon a Site Plan for a Sit-Down Restaurant (IHOP), on 1.4± acres, located on the north side of US 380, west of Coit Road. The property is zoned Planned Development-2 (PD-2). (D19-0011). 3h. Consider and act upon a Final Plat for Prosper Commons, Block B, Lot 3, on 1.4± acres, located on the north side of US 380, west of Coit Road. The property is zoned Planned Development-2 (PD-2). (D19-0012). AGENDA Regular Meeting of the Prosper Planning & Zoning Commission Prosper Town Hall Council Chambers 200 S. Main Street, Prosper, Texas Tuesday, February 19, 2019, 6:00 p.m. Prosper is a place where everyone matters. 3i. Consider and act upon a Conveyance Plat for Prosper School Church Addition, Block A, Lots 1-3, on 56.1± acres, located on the north side of Fishtrap Road, east of Teel Parkway. The property is zoned Agricultural (A). (D19-0013). 3j. Consider and act upon a Site Plan for a Bank with Drive-Through (Farmers Bank & Trust), on 1.0± acre, located on the east side of Preston Road, south of Prosper Trail. The property is zoned Retail (R). (D19-0016). 3k. Consider and act upon a Final Plat for North Preston Village, Block A, Lot 3, on 1.0± acre, located on the east side of Preston Road, south of Prosper Trail. The property is zoned Retail (R). (D19-0017). REGULAR AGENDA If you wish to address the Planning & Zoning Commission during the regular agenda, please fill out a “Speaker Request Form” and present it to the Chair prior to the meeting. Citizens wishing to address the Planning & Zoning Commission for items listed as public hearings will be recognized by the Chair. Those wishing to speak on a non-public hearing related item will be recognized on a case-by-case basis, at the discretion of the Planning & Zoning Commission. 4. Consider and act upon a request for a Façade Exception for 7-Eleven in Victory at Frontier, located on the southwest corner of Preston Road and Frontier Parkway. (MD19-0001). 5. Conduct a Public Hearing, and consider and act upon a request to amend Planned Development-75 (PD-75), generally to modify the Office District, on 67.7± acres, located on the northwest corner of Prosper Trail and Dallas Parkway. (Z18-0019). 6. Review actions taken by the Town Council and possibly direct Town Staff to schedule topic(s) for discussion at a future meeting. 7. Adjourn. Note: The order in which items are heard on the agenda is subject to change. CERTIFICATION I, the undersigned authority, do hereby certify that this Notice of Meeting was posted at Prosper Town Hall, located at 200 S. Main Street, Prosper, Texas 75078, a place convenient and readily accessible to the general public at all times, and said Notice was posted by 5:00 p.m., on Friday, February 15, 2019, and remained so posted at least 72 hours before said meeting was convened. _______________________________ _________________________ Lauren Field, Deputy Town Secretary Date Notice Removed Pursuant to Section 551.071 of the Texas Government Code, the Town Council reserves the right to consult in closed session with its attorney and to receive legal advice regarding any item listed on this agenda. NOTICE Pursuant to Town of Prosper Ordinance No. 13-63, all speakers other than Town of Prosper staff are limited to three (3) minutes per person, per item, which may be extended for an additional two (2) minutes with approval of a majority vote of the Town Council. NOTICE OF ASSISTANCE AT PUBLIC MEETINGS: The Prosper Town Hall is wheelchair accessible. For special services or assistance, please contact the Town Secretary’s Office at (972) 569-1011 at least 48 hours prior to the meeting time. Page 1 ] 1. Call to Order / Roll Call The meeting was called to order at 6:00 p.m. Commissioners present: Chairman Charles Cotten, Vice-Chairman Bobby Atteberry, Secretary Brandon Daniel, Amy Bartley, Joe Grinstead, Chris Long, and Sarah Peterson. Staff present: Hulon Webb, Executive Director of Development and Community Services; Alex Glushko, Planning Manager; Scott Ingalls, Senior Planner; and Evelyn Mendez, Planning Technician. 2. Recitation of the Pledge of Allegiance. 3. CONSENT AGENDA 3a. Consider and act upon minutes from the January 15, 2019, Planning & Zoning Commission Regular meeting. 3b. Consider and act upon a Final Plat for Windsong Ranch Marketplace, Block A, Lot 10, on 11.1± acres, located north of US 380 and west of Windsong Parkway. The property is zoned Planned Development-40 (PD-40). (D18-0093). 3c. Consider and act upon a Site Plan for a beauty salon, on 0.4± acre, located at 306 E. Broadway Street, west of Church Street. The property is zoned Downtown Office (DTO). (D18-0129). 3d. Consider and act upon a Final Plat for Windsong Ranch, Phase 2C-2, for 154 townhouse lots, nine (9) single family lots, and nine (9) HOA/open space lots, on 21.4± acres, located on the west side of Teel Parkway, south of Fishtrap Road. The property is zoned Planned Development-40 (PD-40). (D18-0136). 3e. Consider and act upon a Site Plan for three (3) office buildings, in Windmill Hill, on 9.9± acres, located on the south side of Broadway Street, west of Preston Road. The property is zoned Planned Development-93 (PD-93). (D19-0002). 3f. Consider and act upon a Final Plat for Windmill Hill, Block A, Lot 1, on 9.9± acres, located on the south side of Broadway Street, west of Preston Road. The property is zoned Planned Development-93 (PD-93). (D19-0003). 3g. Consider and act upon a Conveyance Plat for Windmill Hill, Block A, Lots 1 and 2, on 11.8± acres, located on the southwest corner of Broadway Street and Preston Road. The property is zoned Planned Development-93 (PD-93). (D19-0004). 3h. Consider and act upon a Site Plan for Windsong Ranch Phase 2C-2, on 21.4± acres, located on the west side of Teel Parkway, south of Fishtrap Road. The property is zoned Planned Development-40 (PD-40). (D19-0005). MINUTES Regular Meeting of the Prosper Planning & Zoning Commission Prosper Town Hall Council Chambers 200 S. Main Street, Prosper, Texas Tuesday, February 5, 2019, 6:00 p.m. Prosper is a place where everyone matters. Page 2 Commissioner Bartley requested Item 3c. be pulled from the Consent Agenda. Motioned by Atteberry, seconded by Bartley, to approve Items 3a., 3b., 3d., 3e., 3f., 3g., and 3h. on the Consent Agenda, subject to Town staff recommendations. Motion approved 7-0. Bartley: Inquired about the beauty salon operations and information regarding the proposed parking. Glushko: Provided information on the required parking ratio and parking regulations in the Downtown Office (DTO) District. Ben Hammond (Property Owner): Provided information regarding the beauty salon operation. Matt Moore (Applicant): Indicated intent to work with staff to provide additional parking spaces and/or paving, if possible. Motioned by Bartley, seconded by Grinstead, to approve Item 3c., subject to Town staff recommendations. Motion approved 7-0. REGULAR AGENDA 4. Conduct a Public Hearing, and consider and act upon a request to amend Planned Development-75 (PD-75) generally to modify the office tract, on 67.6± acres, located on the northwest corner of the Dallas Parkway and Prosper Trail. (Z18-0019). Ingalls: Recommended the Commission table the item and continue the Public Hearing to the February 19, 2019, Planning & Zoning Commission meeting, to allow time for the applicant to address staff comments. Motioned by Atteberry, seconded by Long, to table Item 4 and continue the Public Hearing to the February 19, 2019, Planning & Zoning Commission meeting. Motion approved 7-0. 5. Consider and act upon a Site Plan for Prosper ISD Middle School No. 4, on 31.2± acres, located on the north side of Fishtrap Road, east of Teel Parkway. The property is zoned Agricultural (A). (D18-0131). Ingalls: Summarized the request and presented exhibits provided by the applicant, including the proposed solid living screening in lieu of a masonry wall. Daniel: Requested more information regarding the temporary buildings shown on the Site Plan. Tom Rutledge (Applicant): Provided general information about the proposed Site Plan. Dr. Greg Bradley (PISD Asst. Superintendent): Provided an overview of the District’s plan for growth and the possible need for additional temporary buildings in the future. Commissioners voiced support for the project, and solid living screening in lieu of a masonry wall. Motioned by Grinstead, seconded by Daniel, to approve Item 5, including solid living screening in lieu of a masonry wall, subject to Town staff recommendations. Motion approved 7-0. Page 3 6. Conduct a Public Hearing and consider and act upon a Replat for Whispering Farms, Phase 1, Block A, Lots 8 and 9, for two (2) single family residential lots, on 3.4± acres, located at 2540 and 2541 Westview Court. The property is zoned Planned Development-5-Single Family-15 (PD-5-SF-15). (D18-0135). Glushko: Summarized the request and presented exhibits provided by the applicant. Chairman Cotten opened the Public Hearing. There being no speakers the Public Hearing was closed. Motioned by Atteberry, seconded by Long, to approve Item 6, subject to Town staff recommendations. Motion approved 7-0. 7. Conduct a Public Hearing, and consider and act upon a request to rezone a portion of Planned Development-3 (PD-3) to Planned Development-Office (PD-O), on 12.9± acres, located south of Prosper Trail, east of Cook Lane. (Z18-0018). Ingalls: Summarized the request and presented exhibits, noting the project phasing, proposed access to the subject property, screening, and communication towers. Cotten: Inquired about the timing of construction, as well as proposed screening. Chairman Cotten opened the Public Hearing. There being no speakers the Public Hearing was closed. Motioned by Long, seconded by Bartley, to approve Item 7, subject to Town staff recommendations. Motion approved 7-0. 8. Review actions taken by the Town Council and possibly direct Town Staff to schedule topic(s) for discussion at a future meeting. Glushko: Provided a summary of recent action taken by Town Council. 9. Adjourn. Motioned by Atteberry, seconded by Grinstead, to adjourn. Motion approved 7-0 at 6:35 p.m. ___________________________________ ______________________________________ Evelyn Mendez, Planning Technician Brandon Daniel, Secretary Page 1 of 1 To: Planning & Zoning Commission Item No. 3b From: Pamela Clark, Planning/GIS Specialist Through: Alex Glushko, AICP, Planning Manager Re: Planning & Zoning Commission Meeting – February 19, 2019 Agenda Item: Consider and act upon a Site Plan for a Convenience Store and Restaurant with Gas Pumps (7- Eleven), on 1.4± acres, located on southwest corner of Preston Road and Frontier Parkway. The property is zoned Planned Development-10 (PD-10). (D18-0127). Description of Agenda Item: The Site Plan shows a 6,487 square foot convenience store and restaurant with gas pumps. Access is provided from Preston Road and Frontier Parkway. Adequate parking has been provided. The Site Plan conforms to the PD-10 development standards. As companion items, the Final Plat for Victory at Frontier, Block A, Lot 2 (D18-0128) and a request for a Façade Exception for 7-Eleven (MD19-0001), are on the February 19, 2019, agenda. Attached Documents: 1. Location Map 2. Site Plan Town Staff Recommendation: Town staff recommends approval of the Site Plan subject to: 1. Planning & Zoning Commission and Town Council approval of a Façade Exception. 2. Town staff approval of civil engineering, irrigation plans, open space plans, and address plans. 3. Town staff approval of all fire hydrants, fire department connections (FDC) and fire lanes, including widths, radii, and location. Prosper is a place where everyone matters. PLANNING D18-0127 FRONTIER PKWY PRESTON RDCHEYENNE DRLARIAT DRPRESTON RD±0 210 420105 Feet FOOD/BEVMERCHFOOD/BEVMERCH SWITCHGEAR & METER PROPANECAGE BULKCO2 TRASH RECYCLE USED COOKING OIL DRAINAGE & SANITARYSEWER EASEMENTDOC. NO. 2018-699 P.R.C.C.T. 10' WATER EASEMENT DOC. NO. 20080623000754670R.P.R.C.C.T. 24' DRAINAGE & SANITARYSEWER EASEMENT DOC. NO. 2018-699P.R.C.C.T.FRONTIER PARKWAYN. PRESTON ROAD (STATE HIGHWAY 289) LOT 3, BLOCK A VICTORY AT FRONTIERDOC. NO. 2018-699 P.R.CC.T. LOT 3, BLOCK A VICTORY AT FRONTIERDOC. NO. 2018-699 P.R.CC.T. LOT 2, BLOCK A 59,998 SQ.FT. 1.377 ACRES VICTORY AT FRONTIER DOC. NO. 2018-699 P.R.CC.T. 30' RIGHT-OF-WAY DEDICATION DOC. NO. 2018-699P.R.C.C.T.DN88°35'36"W263.84'N0°15'13"E 237.43'S89°53'39"E211.81'S1°23'32"W 117.44' S4°45'06"E 100.58' S44°42'27"E11.61'FH20'6.5'59.32'20'12'12'9'5'11' 9'TYP. 120.66' 4.9' 12'12'16'9'TYP. 17.47' 1.55' 24'20'30.5' 30' BUILDING LINE /LANDSCAPE SETBACK 24'36'30'152.04'12.34' 6' 18' 20'9'TYP.24'R10'55.18'10'5'10' 20.1' 17.13'164.37'39.4'30' BUILDING LINE /LANDSCAPESETBACK93.4'40.5'29.17'24'FIRE LANE /ACCESS, DRAINAGE UTILITY ESMT.24'FIRE LANE / ACCESS, DRAINAGE UTILITY ESMT. PROPOSED 6,487 SF BUILDING(GAS STATION: 4,971 SF) ( RESTAURANT 1,516 SF)(OUTDOOR DINING: 510 SF)FFE=524.75 5' 25' WATER ESMT. 2 1 510 SF OUTDOORSEATINGAREA PROP. FUEL CANOPY (PER FUEL PLANS) PROP. AIR/WATER /VACUUMSTATION.REFER TO ARCH. PROP. FUELVENTS PROP. 8' TRASH ENCLOSURE W/ BRICK VENEER TO MATCH BUILDING AND W/METAIL GATES EQUAL IN HIEGHT OF THEWALL ENCLOSURE PROP. PAD MOUNTEDTRANSFORMERW/ SCREENING PROP. PEDESTRIANACCESS ESMT. 404.78' TO INTERSECTION 272.8' TO INTERSECTION1,356 TO COLEMAN ST PROP. B.F.R. PROP.SERVICE DOOR PROP. PIPE BOLLARD TYP. PROP. PIPEBOLLARD TYP. PROP. B.F.R. PROP. B.F.R. EX. TRAFFICSIGNAL LIGHT EX. TRAFFICSIGNAL LIGHT PROP. B.F.R.12'18'30'30' LOADING ZONE PROP. SCREEN WALL R 3 0 ' 215.01' STORAGE24' 100' TRANSITION PROP. RIGHT TURNLANE PROP. B.F.R. PROP. B.F.R. R1 0 ' R2 2 ' 24' FDC 3 HEADLIGHT SCREENIGN HEADLIGHT SCREENIGN HEADLIGHTSCREENIGN R30'R5 4 ' R3 0 'R30'R20'R5'PROP. B.F.R.24'R5'R 3 'R3'R5 ' R2' R54'R 3 0 'R30'R225'R225'R25'R30' EXISTING CURB INELTTO BE REMOVED EXISTING SIGN TO BE RELOCATED R30'R3 0 ' R3 0 '30.93'32' R 3 ' 50.5' EXISTING POWER POLETO REMAIN EXISTING POWER POLE TO REMAIN 5'34.5' PROP. FIRE HYDRANT 10'R95'R105'R115'EXISTINGFIRE HYDRANT TO REMAIN 25'15'16.2' PROP. FIRE HYDRANTBY OTHERS PROP. FIRE HYDRANT EXISTING SANITARY SEWER MANHOLE GTPROP. CURB INLET PROP. JUNCTION BOX PROP. GRATE INLET PROP. GRATE INLET PROP.GRATE INLET PROP. DROP INLET WATER ESMT. PROP. CURB INELTR30'24'24'24'53'PROP. FIREHYDRANTBY OTHERS WATER ESMT. EXISTING SANITARY SEWER MANHOLE EXISTING SANITARYSEWER MANHOLE 5'5'PROP. 15' WATER ESMT.40.5'8'20.5'13.9'35'WATER ESMT.R3'R3'5' STREET ESMT.DATENo.REVISIONBYDATE: SHEET File No. 2018-135 2/7/2019 CHECKED: MKT DRAWN:MKT DESIGN:7 ELEVENLOT 2, BLOCK AVICTORY AT FRONTIERPROSPER, TEXAS1903 CENTRAL DRIVE, SUITE #406PHONE: 817.281.0572BEDFORD, TX 76021 WWW.CLAYMOOREENG.COMTEXAS REGISTRATION #14199 ASD PRELIMINARY CLAYMOORE ENGINEERING SITE PLAN(SHEET 1 OF 2)SP-1 COUNTY SURVEY:ABSTRACT NO. COLLIN -- CITY:STATE: TOWN OF PROSPER TEXAS LEGAL DESCRIPTION: DEVELOPER: APPLICANT: CLAYMOORE ENGINEERING, INC. 1903 CENTRAL DRIVE, SUITE #406 BEDFORD, TX 76021 PH: 817.281.0572 SURVEYOR: WINDROSE LAND SURVEYING & PLATTING 220 SOUTH ELM STREET, SUITE 200 LEWISVILLE, TX 75057 PH: 214.217.2544 SCHAFFER CONSTRUCTION 2601 NETWORK BLVD., SUITE #413 FRISCO, TEXAS 75034 PH: 972.951.7851 LOT 2, BLOCK A VICTORY AT FRONTIER DOC. NO. 2018-699 DOC. P.R.C.C.T. 1.377 ACRES (59,998 SF) 7 ELEVEN CONTACT NAME: SHANE PARTRIDGE CONTACT NAME: MATT MOORE CONTACT NAME: JACK BARTON SITE PLAN CASE #: D18-0127 0 GRAPHIC SCALE 1 inch = ft. 20 20 40 20 10 ACCORDING TO MAP NO. 48085C0120J, DATED JUNE 2, 2009 OF THE NATIONAL FLOOD INSURANCE PROGRAM MAP, FLOOD INSURANCE RATE MAP OF COLLIN COUNTY, TEXAS, FEDERAL EMERGENCY MANAGEMENT AGENCY, FEDERAL INSURANCE ADMINISTRATION, THIS PROPERTY IS WITHIN ZONE "X" (UNSHADED) AND IS NOT WITHIN A SPECIAL FLOOD HAZARD AREA. FLOODPLAIN NOTE TOWN OF PROSPER SITE PLAN GENERAL NOTES: 1. DUMPSTERS AND TRASH COMPACTORS SHALL BE SCREENED IN ACCORDANCE WITH THE ZONING ORDINANCE. 2. OPEN STORAGE, WHERE PERMITTED, SHALL BE SCREENED IN ACCORDANCE WITH THE ZONING ORDINANCE. 3. OUTDOOR LIGHTING SHALL COMPLY WITH THE LIGHTING AND GLARE STANDARDS CONTAINED WITHIN THE ZONING ORDINANCE AND SUBDIVISION ORDINANCE. 4. LANDSCAPING SHALL CONFORM TO LANDSCAPE PLANS APPROVED BY THE TOWN. 5. ALL ELEVATIONS SHALL COMPLY WITH THE STANDARDS CONTAINED WITHIN THE ZONING ORDINANCE. 6. BUILDINGS OF 5,000 SQUARE FEET OR GREATER SHALL BE 100% FIRE SPRINKLED. ALTERNATIVE FIRE PROTECTION MEASURES MAY BE APPROVED BY THE FIRE DEPARTMENT. 7. FIRE LANES SHALL BE DESIGNED AND CONSTRUCTED PER TOWN STANDARDS OR AS DIRECTED BY THE FIRE DEPARTMENT. 8. TWO POINTS OF ACCESS SHALL BE MAINTAINED FOR THE PROPERTY AT ALL TIMES. 9. SPEED BUMPS/HUMPS ARE NOT PERMITTED WITHIN A FIRE LANE. 10. HANDICAPPED PARKING AREAS AND BUILDING ACCESSIBILITY SHALL CONFORM TO THE AMERICANS WITH DISABILITIES ACT (ADA) AND WITH THE REQUIREMENTS OF THE CURRENT, ADOPTED BUILDING CODE. 11. ALL SIGNAGE IS SUBJECT TO BUILDING OFFICIAL APPROVAL. 12. ALL FENCES AND RETAINING WALLS SHALL BE SHOWN ON THE SITE PLAN AND ARE SUBJECT TO BUILDING OFFICIAL APPROVAL. 13. ALL EXTERIOR BUILDING MATERIALS ARE SUBJECT TO BUILDING OFFICIAL APPROVAL AND SHALL CONFORM TO THE APPROVED FAÇADE PLAN. 14. SIDEWALKS OF NOT LESS THAN SIX (6’) FEET IN WIDTH ALONG THOROUGHFARES AND COLLECTORS AND FIVE (5’) IN WIDTH ALONG RESIDENTIAL STREETS, AND BARRIER FREE RAMPS AT ALL CURB CROSSINGS SHALL BE PROVIDED PER TOWN STANDARDS. 15. APPROVAL OF THE SITE PLAN IS NOT FINAL UNTIL ALL ENGINEERING PLANS ARE APPROVED BY THE ENGINEERING DEPARTMENT. 16. SITE PLAN APPROVAL IS REQUIRED PRIOR TO GRADING RELEASE. 17. ALL NEW ELECTRICAL LINES SHALL BE INSTALLED AND/OR RELOCATED UNDERGROUND. 18. ALL MECHANICAL EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW IN ACCORDANCE WITH THE ZONING ORDINANCE. 19. ALL LANDSCAPE EASEMENTS MUST BE EXCLUSIVE OF ANY OTHER TYPE OF EASEMENT. 20. IMPACT FEES WILL BE ASSESSED IN ACCORDANCE WITH THE LAND USE CLASSIFICATION(S) IDENTIFIED ON THE SITE DATA SUMMARY TABLE; HOWEVER, CHANGES TO THE PROPOSED LAND USE AT THE TIME CO AND/OR FINISH-OUT PERMIT MAY RESULT IN ADDITIONAL IMPACT FEES AND/OR PARKING REQUIREMENTS. 21. ALL DIMENSIONS ARE TO FACE OF CURB UNLESS OTHERWISE NOTED. 22. THE APPROVAL OF A SITE PLAN SHALL BE EFFECTIVE FOR A PERIOD OF EIGHTEEN (18) MONTHS FROM THE DATE OF APPROVAL BY THE PLANNING & ZONING COMMISSION, AT THE END OF WHICH TIME THE APPLICANT MUST HAVE SUBMITTED AND RECEIVED APPROVAL OF ENGINEERING PLANS AND BUILDING PERMITS. IF THE ENGINEERING PLANS AND BUILDING PERMITS ARE NOT APPROVED, THE SITE PLAN APPROVAL, TOGETHER WITH ANY PRELIMINARY SITE PLAN FOR THE PROPERTY, IS NULL AND VOID. BENCHMARK: 1. AN 'X' CUT ON A CURB INLET WHICH BEARS S13°47'E,84.93' FROM THE SOUTHEAST PROPERTY CORNER. POSTED ELEVATION: 708.16' 2. AN 'X' CUT SET WHICH BEARS S02°38'W, 458.75' FROM THE SOUTHWEST PROPERTY CORNER. ELEVATION:704.14 WATER METER SCHEDULE ID TYPE SIZE NO. DOM.2" 1 IRR. 1 1/2"1 1 2 *NO 100-YEAR FLOODPLAIN EXISTS ON THE SITE* LEGEND 6" MEDIUM DUTY CONCRETE PAVEMENT. 5" LIGHT DUTY CONCRETE PAVEMENT. 8" DUMPSTER AREA CONCRETE PAVEMENT. PROPOSED CONCRETE SIDEWALK. PROPOSED CONCRETE CURB AND GUTTER. PARKING COUNT PROPOSED SIDEWALK PER CITY STANDARDS PROPOSED DRIVEWAY PAVEMENT PER CITY STANDARDS. N.T.S. VICINITY MAP NN PRESTON RDFRONTIER PKWY SITE E PROSPER TRAIL PROP. MUTUAL ACCESS DRIVE TO NEXT MEDIAN OPENING FUTURE MEDIAN (BY OTHERS) GREASE TRAP 1000 gal.13MATCHLINE 24' DRAINAGE & SANITARYSEWER EASEMENT DOC. NO. 2018-699P.R.C.C.T. LOT 3, BLOCK AVICTORY AT FRONTIER DOC. NO. 2018-699P.R.CC.T.24'24'PROP. FIRE HYDRANT BY OTHERS WATER ESMT. EXISTING SANITARY SEWER MANHOLE EXISTING SANITARYSEWER MANHOLE DATENo.REVISIONBYDATE: SHEET File No. 2018-135 2/7/2019 CHECKED: MKT DRAWN:MKT DESIGN:7 ELEVENLOT 2, BLOCK AVICTORY AT FRONTIERPROSPER, TEXAS1903 CENTRAL DRIVE, SUITE #406PHONE: 817.281.0572BEDFORD, TX 76021 WWW.CLAYMOOREENG.COMTEXAS REGISTRATION #14199 ASD PRELIMINARY CLAYMOORE ENGINEERING SITE PLAN(SHEET 2 OF 2)SP-2 COUNTY SURVEY:ABSTRACT NO. COLLIN -- CITY:STATE: TOWN OF PROSPER TEXAS LEGAL DESCRIPTION: DEVELOPER: APPLICANT: CLAYMOORE ENGINEERING, INC. 1903 CENTRAL DRIVE, SUITE #406 BEDFORD, TX 76021 PH: 817.281.0572 SURVEYOR: WINDROSE LAND SURVEYING & PLATTING 220 SOUTH ELM STREET, SUITE 200 LEWISVILLE, TX 75057 PH: 214.217.2544 SCHAFFER CONSTRUCTION 2601 NETWORK BLVD., SUITE #413 FRISCO, TEXAS 75034 PH: 972.951.7851 LOT 2, BLOCK A VICTORY AT FRONTIER DOC. NO. 2018-699 DOC. P.R.C.C.T. 1.377 ACRES (59,998 SF) 7 ELEVEN CONTACT NAME: SHANE PARTRIDGE CONTACT NAME: MATT MOORE CONTACT NAME: JACK BARTON SITE PLAN CASE #: D18-0127 0 GRAPHIC SCALE 1 inch = ft. 20 20 40 20 10 ACCORDING TO MAP NO. 48085C0120J, DATED JUNE 2, 2009 OF THE NATIONAL FLOOD INSURANCE PROGRAM MAP, FLOOD INSURANCE RATE MAP OF COLLIN COUNTY, TEXAS, FEDERAL EMERGENCY MANAGEMENT AGENCY, FEDERAL INSURANCE ADMINISTRATION, THIS PROPERTY IS WITHIN ZONE "X" (UNSHADED) AND IS NOT WITHIN A SPECIAL FLOOD HAZARD AREA. FLOODPLAIN NOTE TOWN OF PROSPER SITE PLAN GENERAL NOTES: 1. DUMPSTERS AND TRASH COMPACTORS SHALL BE SCREENED IN ACCORDANCE WITH THE ZONING ORDINANCE. 2. OPEN STORAGE, WHERE PERMITTED, SHALL BE SCREENED IN ACCORDANCE WITH THE ZONING ORDINANCE. 3. OUTDOOR LIGHTING SHALL COMPLY WITH THE LIGHTING AND GLARE STANDARDS CONTAINED WITHIN THE ZONING ORDINANCE AND SUBDIVISION ORDINANCE. 4. LANDSCAPING SHALL CONFORM TO LANDSCAPE PLANS APPROVED BY THE TOWN. 5. ALL ELEVATIONS SHALL COMPLY WITH THE STANDARDS CONTAINED WITHIN THE ZONING ORDINANCE. 6. BUILDINGS OF 5,000 SQUARE FEET OR GREATER SHALL BE 100% FIRE SPRINKLED. ALTERNATIVE FIRE PROTECTION MEASURES MAY BE APPROVED BY THE FIRE DEPARTMENT. 7. FIRE LANES SHALL BE DESIGNED AND CONSTRUCTED PER TOWN STANDARDS OR AS DIRECTED BY THE FIRE DEPARTMENT. 8. TWO POINTS OF ACCESS SHALL BE MAINTAINED FOR THE PROPERTY AT ALL TIMES. 9. SPEED BUMPS/HUMPS ARE NOT PERMITTED WITHIN A FIRE LANE. 10. HANDICAPPED PARKING AREAS AND BUILDING ACCESSIBILITY SHALL CONFORM TO THE AMERICANS WITH DISABILITIES ACT (ADA) AND WITH THE REQUIREMENTS OF THE CURRENT, ADOPTED BUILDING CODE. 11. ALL SIGNAGE IS SUBJECT TO BUILDING OFFICIAL APPROVAL. 12. ALL FENCES AND RETAINING WALLS SHALL BE SHOWN ON THE SITE PLAN AND ARE SUBJECT TO BUILDING OFFICIAL APPROVAL. 13. ALL EXTERIOR BUILDING MATERIALS ARE SUBJECT TO BUILDING OFFICIAL APPROVAL AND SHALL CONFORM TO THE APPROVED FAÇADE PLAN. 14. SIDEWALKS OF NOT LESS THAN SIX (6’) FEET IN WIDTH ALONG THOROUGHFARES AND COLLECTORS AND FIVE (5’) IN WIDTH ALONG RESIDENTIAL STREETS, AND BARRIER FREE RAMPS AT ALL CURB CROSSINGS SHALL BE PROVIDED PER TOWN STANDARDS. 15. APPROVAL OF THE SITE PLAN IS NOT FINAL UNTIL ALL ENGINEERING PLANS ARE APPROVED BY THE ENGINEERING DEPARTMENT. 16. SITE PLAN APPROVAL IS REQUIRED PRIOR TO GRADING RELEASE. 17. ALL NEW ELECTRICAL LINES SHALL BE INSTALLED AND/OR RELOCATED UNDERGROUND. 18. ALL MECHANICAL EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW IN ACCORDANCE WITH THE ZONING ORDINANCE. 19. ALL LANDSCAPE EASEMENTS MUST BE EXCLUSIVE OF ANY OTHER TYPE OF EASEMENT. 20. IMPACT FEES WILL BE ASSESSED IN ACCORDANCE WITH THE LAND USE CLASSIFICATION(S) IDENTIFIED ON THE SITE DATA SUMMARY TABLE; HOWEVER, CHANGES TO THE PROPOSED LAND USE AT THE TIME CO AND/OR FINISH-OUT PERMIT MAY RESULT IN ADDITIONAL IMPACT FEES AND/OR PARKING REQUIREMENTS. 21. ALL DIMENSIONS ARE TO FACE OF CURB UNLESS OTHERWISE NOTED. 22. THE APPROVAL OF A SITE PLAN SHALL BE EFFECTIVE FOR A PERIOD OF EIGHTEEN (18) MONTHS FROM THE DATE OF APPROVAL BY THE PLANNING & ZONING COMMISSION, AT THE END OF WHICH TIME THE APPLICANT MUST HAVE SUBMITTED AND RECEIVED APPROVAL OF ENGINEERING PLANS AND BUILDING PERMITS. IF THE ENGINEERING PLANS AND BUILDING PERMITS ARE NOT APPROVED, THE SITE PLAN APPROVAL, TOGETHER WITH ANY PRELIMINARY SITE PLAN FOR THE PROPERTY, IS NULL AND VOID. BENCHMARK: 1. AN 'X' CUT ON A CURB INLET WHICH BEARS S13°47'E,84.93' FROM THE SOUTHEAST PROPERTY CORNER. POSTED ELEVATION: 708.16' 2. AN 'X' CUT SET WHICH BEARS S02°38'W, 458.75' FROM THE SOUTHWEST PROPERTY CORNER. ELEVATION:704.14 *NO 100-YEAR FLOODPLAIN EXISTS ON THE SITE* LEGEND 6" MEDIUM DUTY CONCRETE PAVEMENT. 5" LIGHT DUTY CONCRETE PAVEMENT. 8" DUMPSTER AREA CONCRETE PAVEMENT. PROPOSED CONCRETE SIDEWALK. PROPOSED CONCRETE CURB AND GUTTER. PARKING COUNT PROPOSED SIDEWALK PER CITY STANDARDS PROPOSED DRIVEWAY PAVEMENT PER CITY STANDARDS.N.T.S. VICINITY MAP NN PRESTON RDFRONTIER PKWY SITE E PROSPER TRAIL MATCHLINEPROP. DEVLOPMENT (BY OTHERS)PROP. PAVEMENT(BY OTHERS) Page 1 of 1 To: Planning & Zoning Commission Item No. 3c From: Pamela Clark, Planning/GIS Specialist Through: Alex Glushko, AICP, Planning Manager Re: Planning & Zoning Commission Meeting – February 19, 2019 Agenda Item: Consider and act upon a Final Plat for Victory at Frontier, Block A, Lot 2, on 1.4± acres, located on the southwest corner of Preston Road and Frontier Parkway. The property is zoned Planned Development-10 (PD-10). (D18-0128). Description of Agenda Item: The Final Plat dedicates all easements necessary for development and conforms to the PD-10 development standards. As companion items, the Site Plan for a 7-Eleven convenience store and restaurant with gas pumps (D18-0127) and a request for a Façade Exception for 7-Eleven (MD19-0001), are on the February 19, 2019 agenda. Attached Documents: 1. Location Map 2. Final Plat Town Staff Recommendation: Town staff recommends approval of the Final Plat, subject to: 1. Town staff approval of all additions and/or alterations to the easements and dedications on the Final Plat. Prosper is a place where everyone matters. PLANNING FRONTIER PKWY PRESTON RDCHEYENNE DRLARIAT DR D18-0128 ±0 210 420105 Feet FRONTIER PARKWAY VARIABLE WIDTH RIGHT-OF-WAY JONES JERRAL W ETALVOLUME 5184 PAGE 212D.R.C.C.T. (DOC. NO. 20090721000915890, D.R.D.C.T.) KEERAN FAMILY PARTNERSHIP, LTD.VOL. 4957, PG. 2455D.R.C.C.T. LOT 2, BLOCK A 59,998 SQ.FT. 1.377 ACRES S77°20'03" E 7 6 . 9 0 ' S89°53'39"E 178.70'S01°23'32"W 117.44'S04°45'06"E 100.58'S01°24'24"W 85.46'76.26'N88°35'36"W 263.84' S77°20'03"E38.42'S89°53'39"E 211.81' S44°42'27"E11.61'N00°15'13"E 237.43'S01°24'24"W9.20'N. PRESTON ROAD(STATE HIGHWAY 289)VARIABLE WIDTH RIGHT-OF-WAY(VOLUME 621, PG. 114, D.R.D.C.T.)N44°42'27"W42.29' S89°25'42"W 372.15' BRYAN ROAD RETAIL PARTNERS, LP DOC. NO. 20180920001181080 D.R.C.C.T. LOT 3, BLOCK A VICTORY AT FRONTIER DOC. NO. 2018-699 P.R.CC.T. LOT 3, BLOCK A VICTORY AT FRONTIER DOC. NO. 2018-699 P.R.CC.T. 38.30'961.81' REMAINDER OF VICTORY AT FRONTIER, LLC DOC. NO. 20161122001590950 D.R.C.C.T. REMAINDER OF VICTORY AT FRONTIER, LLC DOC. NO. 20161122001590950 D.R.C.C.T. POINT OF BEGINNING LOT 2, BLOCK A VICTORY AT FRONTIER DOC. NO. 2018-699 P.R.CC.T.S04°16'09"W 200.25'S88°35'36"E 73.27'S01°24'24"W 254.82'S67°5 4 ' 1 0 " E 2 8 2 . 4 5 ' LOT 1, BLOCK A VICTORY AT FRONTIER DOC. NO. 2018-699 P.R.CC.T. DRAWN BY: E.R. DATE: 12/13/2018 CHECKED BY: T.M. JOB NO.: 201810027 FINAL PLAT LOT 2, BLOCK A VICTORY AT FRONTIER AN ADDITION TO THE TOWN OF PROSPER, COLLIN COUNTY, TEXAS BEING LOT 2, BLOCK A, VICTORY AT HERITAGE DOC. NO. 2018-699, P.R.C.C.T. 1.377 ACRES OUT OF THE SPENCER RICE SURVEY, ABSTRACT NO. 787, & COLLIN COUNTY SCHOOL LAND SURVEY, ABSTRACT NO. 172 COLLIN COUNTY, TEXAS TOWN OF PROSPER CASE NO. D18-0128 OWNER/DEVELOPER BRYAN ROAD RETAIL PARTNERS, LP 1201 N. RIVERFRONT BLVD., SUITE 100 DALLAS, TX 75207 ENGINEER SURVEYOR'S NOTES: 1. Bearings and distances are based on the State Plane Coordinate System, Texas North Central Zone (4202) North American Datum of 1983 (NAD 83)(US Foot) with a combined scale factor of 1.000152710. 2. This property lies partially within Zone "X" (Unshaded), of the Flood Insurance Rate Map for Collin County, Texas and Incorporated Areas, map no. 48085C0120 J, with an effective date of June 2, 2009 via scaled map location and graphic plotting. 3. The purpose of this plat is to create 1 recorded lot. STATE OF TEXAS § COUNTY OF COLLIN § WHEREAS, Bryan Road Retail Partners, LP is the owner of a tract of land situated in the Spencer Rice Survey, Abstract No. 787 and the Collin County School Land Survey, Abstract No. 172, in the Town of Prosper, Collin County, Texas, being all of Lot 2, Block A of Victory at Frontier, an addition to the Town of Prosper, Collin County, Texas, according to the Plat thereof recorded in Document No. 2018-699 of the Plat Records of Collin County, Texas (P.R.C.C.T.), being that same tract of land conveyed to Bryan Road Retail Partners, LP by deed recorded in Document No. 20180920001181080 of the Deed Records of Collin County, Texas (D.R.C.C.T.) and being more particularly described by metes and bounds as follows (Bearings and distances are based on the State Plane Coordinate System, Texas North Central Zone (4202) North American Datum of 1983 (NAD 83)(US Foot) with a combined scale factor of 1.000152710): BEGINNING at a TXDOT monument found for the easternmost Northeast corner of said Lot 2, at the easterly end of a corner clip at the intersection of the South right-of-way line of Frontier Parkway (variable width right-of-way) and the West right-of-way line of N. Preston Road (State Highway 289) (variable width right-of-way); THENCE, with the West right-of-way line of said N. Preston Road, the following courses and distances: 1. South 01 Degrees 23 Minutes 32 Seconds West, a distance of 117.44 feet to a TXDOT monument found; 2. South 04 Degrees 45 Minutes 06 Seconds East, a distance of 100.58 feet to a 1/2 inch rebar with a cap stamped "KHA" found; 3. South 01 Degrees 24 Minutes 24 Seconds West, a distance of 9.20 feet to a 1/2 inch rebar found for the Southeast corner of said Lot 2, same being the easternmost Northeast corner of Lot 3, Block A of said addition; THENCE North 88 Degrees 35 Minutes 36 Seconds West, departing the West right-of-way line of said N. Preston Road, with the easternmost North line of said Lot 3, and with the South line of said Lot 2, a distance of 263.84 feet to a 1/2 inch rebar with a cap stamped "Windrose" found for the Southwest corner of said Lot 2, same being an interior "ell" corner of said Lot 3; THENCE North 00 Degrees 15 Minutes 13 Seconds East, with the northernmost East line of said Lot 3, and with the West line of said Lot 2, a distance of 237.43 feet to a 1/2 inch rebar with a cap stamped "Windrose" found for the northernmost Northeast corner of said Lot 3, same being the Northwest corner of said Lot 2, and lying on the South right-of-way line of said Frontier Parkway; THENCE South 77 Degrees 20 Minutes 03 Seconds East, with the South right-of-way line of said Frontier Parkway, a distance of 38.42 feet to a 1/2 inch rebar with a cap stamped "Windrose" found for corner; THENCE South 89 Degrees 53 Minutes 39 Seconds East, continuing with the South right-of-way line of said Frontier Parkway, a distance of 211.81 feet to a 1/2 inch rebar with a cap stamped "Windrose" found for the northernmost Northeast corner of said Lot 2, being at the West end of said corner clip; THENCE South 44 Degrees 42 Minutes 27 Seconds East, with the Southwest side of said corner clip, a distance of 11.61 feet to the POINT OF BEGINNING and containing 59,998 square feet or 1.377 acres of land, more or less. NOW, THEREFORE, KNOW ALL MEN BY THESE PRESENTS THAT Bryan Road Retail Partners, LP does hereby certify and adopt this plat designating the herein above described property as FINAL PLAT OF LOT 2, BLOCK A, VICTORY AT FRONTIER, and does hereby dedicate to the public use forever, the streets and alleys shown thereon. Bryan Road Retail Partners, LP, does herein certify the following: 1. The streets and alleys are dedicated for street and alley purposes. 2. All public improvements and dedications shall be free and clear of all debt, liens, and/or encumbrances. 3. The easements and public use areas, as shown, are dedicated to the public use forever for the purposes indicated on this plat. 4. No buildings, fences, trees, shrubs or other improvements or growths shall be constructed or placed upon, over or across the easements as shown, except that landscape improvements may be placed in landscape easements if approved by the Town of Prosper. 5. The Town of Prosper is not responsible for replacing any improvements in, under, or over any easements caused by maintenance or repair. 6. Utility easements may also be used for the mutual use and accommodation of all public utilities desiring to use or using the same unless the easement limits the use to particular utilities, said use by the public utilities being subordinate to the public's and Town of Prosper's use thereof. 7. The Town of Prosper and public utilities shall have the right to remove and keep removed all or parts of any buildings, fences, trees, shrubs or other improvements or growths which may in any way endanger or interfere with the construction, maintenance, or efficiency of their respective systems in the easements. 8. The Town of Prosper and public utilities shall at all times have the full right of ingress and egress to or from their respective easements for the purpose of constructing, reconstructing, inspecting, patrolling, maintaining, reading meters, and adding to or removing all or parts of their respective systems without the necessity at any time procuring permission from anyone. 9. All modifications to this document shall be by means of plat and approved by the Town of Prosper. This plat approved subject to all platting ordinances, rules, regulations and resolutions of the Town of Prosper, Texas. WITNESS MY HAND AND SEAL OF OFFICE, this _____ day of ___________________, 2018. BRYAN ROAD RETAIL PARTNERS, LP By: _________________________________ __________________, ______________ Printed Name Position STATE OF TEXAS § COUNTY OF ______________§ BEFORE ME, the undersigned authority, a Notary Public in and for the State of Texas, on this day personally appeared _______________________, known to me to be the person whose name is subscribed to the foregoing instrument and acknowledged to me that she executed the same for the purposes and consideration therein expressed. GIVEN UNDER MY HAND AND SEAL OF OFFICE this ________day of ______________________ 20____. ___________________________________ Notary Public in and for the State of Texas VICINITY MAP NOT TO SCALE LEGEND OF ABBREVIATIONS D.R.C.C.T. DEED RECORDS, COLLIN COUNTY, TEXAS P.R.C.C.T. PLAT RECORDS, COLLIN COUNTY, TEXAS R.O.W. RIGHT OF WAY C.M. CONTROLLING MONUMENT PRELIMINARY STATE OF TEXAS § COUNTY OF DENTON § This is to certify that I, Thomas W. Mauk, a Registered Professional Land Surveyor of the State of Texas, have platted the subdivision from an actual survey on the ground, and that this plat correctly represents that survey made by me or under my direction and supervision. ______________________________ Thomas W. Mauk, R.P.L.S. No. 5119 STATE OF TEXAS § COUNTY OF DENTON § BEFORE ME, the undersigned authority, a Notary Public in and for the State of Texas, on this day personally appeared Thomas W. Mauk, known to me to be the person whose name is subscribed to the foregoing instrument and acknowledged to me that she executed the same for the purposes and consideration therein expressed. GIVEN UNDER MY HAND AND SEAL OF OFFICE this ________day of ______________________ 20____. ___________________________________ Notary Public in and for the State of Texas CERTIFICATE OF APPROVAL: APPROVED THIS _____ DAY OF ____________, 20___ BY THE PLANNING & ZONING COMMISSION OF THE TOWN OF PROSPER, TEXAS. _________________________ TOWN SECRETARY _________________________ DEVELOPMENT SERVICES DEPARTMENT _________________________ ENGINEERING DEPARTMENT PAGE 1 OF 1 SITE SCALE: 1" = 40' 40'0 20'40'80' ACCESS EASEMENT The undersigned covenants and agrees that the access easement(s) may be utilized by any person or the general public for ingress and egress to other real property, and for the purpose of general vehicular use and access, and for the Fire Department, Police, and emergency use in, along, upon, and across said premises, with the right and privilege at all times of the Town of Prosper, its agents, employees, workmen, and representatives having ingress, egress, and regress in, along, upon, and across said premises. FIRE LANE EASEMENT The undersigned covenants and agrees that he (they) shall construct upon the Fire Lane Easements, as dedicated and shown hereon, a hard surface paved in accordance with town standards and that he (they) shall maintain the same in a state of good repair at all times and keep the same free and clear of any structures, fences, trees, shrubs, or other improvements or obstructions, including but not limited to the parking, loading, or unloading of motor vehicles, trailers, boats, or other impediments to the access of fire apparatus. The maintenance of pavement in accordance to town standards of the Fire Lane Easements is the responsibility of the owner, and the owner shall post and maintain signage in accordance to town standards in conspicuous places along the Fire Lanes, stating "Fire Lane, No Parking". The police or their duly authorized representative is hereby authorized to cause such fire lanes and utility easements to be maintained free and unobstructed at all times for Fire Department and emergency use. LANDSCAPE EASEMENT The undersigned covenants and agrees that the landscape easement and restrictions herein set forth shall run with the land and be binding on the owner(s) of the property in this subdivision, their successors and assigns, and all parties claiming by, through and under them. In the event a replat is requested on all or part of this property, the Town may require any similar or additional restrictions at its sole discretion. The sole responsibility for maintenance and replacement of landscape materials thereof shall be borne by any ‘homeowners’ association hereafter established for the owners of lots in this subdivision and/or the owners of the individual lots within this subdivision. Such maintenance and replacement shall be in conformance with the requirements, standards, and specifications of the Town of Prosper, as presently in effect or as may be hereafter amended. This provision may be enforced by specific performance or by any other remedy allowed by law. This Landscape Easement shall be void of utilities and other elements unless otherwise approved on the plat. 220 ELM STREET, SUITE 200 I LEWISVILLE, TX 75057 I 214.217.2544 FIRM REGISTRATION NO. 10194331 I WINDROSESERVICES.COM ILAND SURVEYING PLATTING WINDROSE 220 Elm St., # 200 - Lewisville, TX 75057 Ph. 972.221.9439 - TFRN# 10063800arthursurveying.com Established 1986 Contact: Eddie Rodriguez FRONTIER PKWY COLEMAN 1903 Central Drive Suite #406 Bedford, Texas 76021 Phone: 817-281-0572 SURVEYOR Page 1 of 1 To: Planning & Zoning Commission Item No. 3d From: Pamela Clark, Planning/GIS Specialist Through: Alex Glushko, AICP, Planning Manager Re: Planning & Zoning Commission Meeting – February 19, 2019 Agenda Item: Consider and act upon a Final Plat for Lakewood, Phase 2, Block A, Lots 1-7, 1X and 2X, and Block B, Lots 1-6, and 1X, for 13 single family residential lots and three (3) HOA/open space lots, on 3.6± acres, located on the east side of Lakewood Drive, north of US 380. The property is zoned Planned Development-87 (PD-87). (D18-0130). Description of Agenda Item: The Final Plat shows 13 single family residential lots and three (3) HOA/open space lots. Access will be provided from Lakewood Drive. The Final Plat conforms to the PD-87 development standards. Attached Documents: 1. Location Map 2. Final Plat Town Staff Recommendation: Town staff recommends approval of the Final Plat subject to: 1. Town staff approval of all additions and/or alterations to the easements and dedications on the Final Plat. Prosper is a place where everyone matters. PLANNING Δ SHEET 1 OF 1 LAKEWOOD, PHASE 2LAKEWOOD PHASE 2 IN THE JAMES STONE SURVEY, ABSTRACT NO. 847 AND THE ISAAC C. WILLIAMSON SURVEY, ABSTRACT NO. 948 TOWN OF PROSPER, COLLIN COUNTY, TEXAS LJA Surveying, Inc. 6 060 North Central Expressway Phone 469.621.0710 Suite 440 Dallas, Texas 75206 T.B.P.L.S. Firm No. 10194465 3.623 GROSS ACRES & 3.214 NET ACRESLOTS 1-7, 1X&2X, BLOCK A; & LOTS 1-6, 1X, BLOCK B OWNER/DEVELOPER:HH LAKEWOOD, LLC c/o Hines, 2200 Ross Avenue Suite 4200W Dallas, Texas 75201 FINAL PLAT D18-0130 50 0 5025 ”“” “”LAKEWOOD, PHASE 2 LOT TABLE LOT BLO(K SV+YLOT W.DTH LOT DEPTH T>PE  A ,( 2 A ,D A ,D A ,D A ,D A ,D A ,D = A , 2= A ,  B ,2 ( 2 B ,D  B ,D B ,2(  B ,D B ,( = B , D18-0130 UNIVERSITY DRLAKEWOOD DR US HIGHWAY 380 RICHLAND B L V D D O V E R D R M O O R L A N D P A S S D R CLARENDON C T HYDE CT OLD SHIRE PATH RDMEADOWBROOK BLVDM A N C H E S T E R A V E MEADOW DELL DR ±0 420 840210 Feet Page 1 of 1 To: Planning & Zoning Commission Item No. 3e From: Scott Ingalls, AICP, Senior Planner Through: Alex Glushko, AICP, Planning Manager Re: Planning & Zoning Commission Meeting – February 19, 2019 Agenda Item: Consider and act upon a Final Plat for the Prosper School Church Addition, Block A, Lot 1, on 30.9± acres, located on the north side of Fishtrap Road, east of Teel Parkway. The property is zoned Agricultural (A). (D18-0132). Description of Agenda Item: The Final Plat dedicates all easements necessary for development and conforms to the Agricultural development standards. As a companion item, the Conveyance Plat for the Prosper School Church Addition, Block A, Lots 1-3 (D19-0013) is on the February 19, 2019 agenda. Attached Documents: 1. Location Map 2. Final Plat Town Staff Recommendation: Town staff recommends approval of the Final Plat, subject to: 1. Town staff approval of all annotations, additions and/or alterations to the easements and dedications on the Final Plat. Prosper is a place where everyone matters. PLANNING D18-0132 FISHTRAP RD PRAIRIE DRARTESIA BLVDLEGACY DRHARPER RDAMISTAD AVE CLEARWATER DR CANYON RDG TOLEDO BEND CT RENMUIR DR DRY CREEK BLVD WHITE ROCK BLVD PALESTINE DRADAMS PLHIGH LINE DR TAHOE TRLNACONA DRELM PARK DRMEDINA LNSPEARGRASS LNHUDSON LNPLACID TRL CANNON DR WALWORTH DRTEXOMA TRLGROVE VALE DRBLUEGILL LNGRAPEVINE RDGBAREFOOT LN WINECUP RD FIRST S T CANARY G R A S S L N ALVARADO DR HIGHL A N D S TVILLAGE PARK LN EASTMINSTER DR GLADEWATER T R C E LAVENDER DRCANDLER DRW E S T W O O D D R CELESTI A L D R AQUILLA WAY ORCHARD DRCRATER CTBRELSFORD PL WOOD VALE DRWINSOR DRCHAUCER DRPRAIRIE DR LEGACY DR±0 530 1,060265 Feet 60' R.O.W. DEDICATION CABINET X, PAGE 14 O.P.R.D.C.T.HUDSON LANE(50' RIGHT-OF-WAY)PALESTINE DRIVE(50' RIGHT-OF-WAY)LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 13 LOT 14 LOT 15 LOT 16 LOT 17 LOT 18 LOT 19 LOT 20 LOT 13LOT 14LOT 15 LOT 16 LOT 17 LOT 18LOT 19LOT 20 DENTON COUNTY FRESH WATER SUPPLY DISTRICT NO. 10 2.461 ACRES DOC. NO. 2006-144396 O.P.R.D.C.T. 40 48 48 HA R P E R R O A D (50' R I G H T - O F - W A Y ) ARTESIA PHASE 1A CABINET X, PAGE 14 O.P.R.D.C.T. 5/8" CIRF"PETITT" 5/8" CIRF"PETITT" 5/8" CIRF"PETITT" 5/8" CIRF"PETITT" "X" CUTFOUND "X" CUTFOUND 1/2" IRF 1/2" IRF 1/2" IRF 1/2" IRF 5/8" CIRF"PETITT" 5/8" CIRF"PETITT" 5/8" CIRF"BGT" 5/8" CIRF"BGT" 5/8" CIRF"PETITT"5/8" CIRF"PETITT" 5/8" CIRF"PETITT" 5/8" CIRF"PETITT" 5/8" CIRF"PETITT" 5/8" CIRF"PETITT" 5/8" CIRF"PETITT" POINT OF BEGINNING BLOCK A, LOT 1 30.890 ACRES1,345,567 SQUARE FEET APPROXIMATE LOCATION F.E.M.A. 100-YEAR FLOODPLAIN APPROXIMATE LOCATION F.E.M.A. 100-YEAR FLOODPLAIN APPROXIMATE LOCATION F.E.M.A. 100-YEAR FLOODPLAIN 5/8" CIRF "PETITT" 5/8" CIRF "PETITT"FOR REFERENCE AT1044.61' WOOD CROSS TIEFENCE POSTFOR REFERENCE AT1011.12' BOUNDARY LINE AGREEMENT DOC. NO. _____________O.P.R.D.C.T. LOT 1LOT 2LOT 3LOT 4 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 13 1X (HOA) 1X (HOA)CHAUCER DRIVE(50' RIGHT-OF-WAY)CLEARWATER DRIVE (50' RIGHT-OF-WAY) A B BPARKS AT LEGACY PHASE IIDOC. NO. 2017-117 O.P.R.D.C.T.LOT 14 LOT 15 LOT 16 19X (HOA) BOUNDARY LINE AGREEMENT DOC. NO. _____________O.P.R.D.C.T. ZONE "X"HARPER ROADPORTION OF HARPER ROADTO BE ABANDONED BYTOWN OF PROSPER DOC. NO.______________ APPROXIMATE LOCATION OFWATER LINE EASEMENT(NO DESCRIPTION IN DOCUMENT)DOC. NO. 2012-43648O.P.R.D.C.T. PORTION OF HARPER ROADTO BE ABANDONED BYTOWN OF PROSPER ORDINANCE NO.______________ FISHTRAP ROAD (VARIABLE WIDTH RIGHT-OF-WAY) 60' RIGHT-OF-WAY, VOLUME 228, PAGE 450, D.R.D.C.T. 5/8" CIRF "PETITT" DENTON COUNTY FRESH WATER SUPPLY DISTRICT NO. 10 39.213 ACRES DOC. NO. 2014-7938 O.P.R.D.C.T. ZONE "A" STREET EASEMENT DOC.NO. _________O.P.R.D.C.T. 5'x20' DRAINAGE EASEMENTDOC.NO. _________O.P.R.D.C.T. 15' FIRELANE, ACCESS,DRAINAGE & UTILITY EASEMENTDOC. NO. ___________O.P.R.D.C.T. 15' UTILITY EASEMENTDOC. NO. _________O.P.R.D.C.T. 10' ACCESS EASEMENTDOC.NO. _________O.P.R.D.C.T. SIDEWALK EASEMENTDOC.NO. _________O.P.R.D.C.T. STREET EASEMENT DOC.NO. _________O.P.R.D.C.T. 5'x20' DRAINAGE EASEMENTDOC.NO. _________O.P.R.D.C.T. VARIABLE WIDTH FIRELANE & UTILITY EASEMENTDOC.NO. _________O.P.R.D.C.T. BLOCK A, LOT 2 PROSPER SCHOOL CHURCH ADDITION DOC. NO. _________ P.R.D.C.T. BLOCK A, LOT 3 PROSPER SCHOOL CHURCH ADDITIONDOC. NO. _________ P.R.D.C.T. 24' FIRELANE & UTILITY EASEMENT 24' FIRELANE & UTILITY EASEMENT 24' FIRELANE & UTILITY EASEMENT24' FIRELANE & UTILITY EASEMENT15' WTR ESMT15' WTR ESMT30' SEWER ESMT30' FIRELANE & UTILITY EASEMENT24' FIRELANE & UTILITY EASEMENT 24' FIRELANE & UTILITY EASEMENT 10' WATER EASEMENTWATER EASEMENT 24' FIRELANE & UTILITY EASEMENT 10' WATER EASEMENT 10' WATER EASEMENT 10' WATER EASEMENT 15' WATER EASEMENT 24' ACCESS EASEMENT 10' WATER EASEMENT 10' WATER EASEMENT 15' UTILITY EASEMENTDOC.NO. _________O.P.R.D.C.T. 15' FIRELANE, ACCESS, DRAINAGE & UTILITY EASEMENTDOC.NO. _________O.P.R.D.C.T. WATER EASEMENT UTILITY EASEMENTDOC. NO. 2009-136113O.P.R.D.C.T. CORONA ARTESIA LLC TRACT VI5.515 ACRES DOC. NO. 208-34098O.P.R.D.C.T.DRAINAGE EASEMENTDOC. NO _________ O.P.R.D.C.T. DRAINAGE EASEMENTDOC. NO _________O.P.R.D.C.T. 30' SEWER EASEMENTDOC. NO. __________O.P.R.D.C.T. FIRELANE, ACCESS,DRAINAGE & UTILITY EASEMENT DOC. NO _________O.P.R.D.C.T. 15' UTILITY EASEMENTDOC. NO. __________ O.P.R.D.C.T. FIRELANE, ACCESS,DRAINAGE & UTILITY EASEMENT DOC. NO _________O.P.R.D.C.T. WATEREASEMENT 30' FIRE LANE, ACCESS,DRAINAGE & UTILITIY EASEMENT 30' SEWER EASEMENTDOC. NO. __________O.P.R.D.C.T. 30' SEWER EASEMENTDOC. NO. __________O.P.R.D.C.T.90.00'90.00'TWO-J PARTNERS, LLLP INST. NO. 2008-50523O.P.R.D.C.T. S 88° 07' 04" E S 89°18'53" E91.64' S 89° 03' 51" WN 00° 52' 46" WS 89°02'54" W 336.06'N 00°16'24" E 1033.71'1047.57'S 00°30'44" W 1233.87'792.73'254.18'ARTESIA PHASE 2C DOC. NO. 2014-20 O.P.R.D.C.T. N.W. CORNER L. NETHERLEY SURVEY,ABSTRACT NO. 962 79 4 7 . 0 0 ' N 4 9 ° 2 9 ' 1 6 " W 25' LANDSCAPE EASEMENT WATEREASEMENT 15' WATER EASEMENT WATER EASEMENT WATER EASEMENT 30' SEWER ESMTWATER EASEMENT 24' FIRE LANE, ACCESS, DRAINAGE & UTILITIY EASEMENT 45' FIRE LANE, & UTILITIY EASEMENT 050 100100 SCALE IN FEET1" = 100'Drawing: L:\Projects\HUC 18414 PISD MS No 4 Ref-PPS 18400\Acad\Deliverables\Final_Plat\2019 02 04 HUC 18414 PISD MS-4 Final Plat.dwg at Feb 05, 2019-10:53am by jmaddoxVICINITY MAP NOT TO SCALE NORTH FRISCO PROSPER 380 COUNTYLINEROADDALLAS NORTH TOLLWAYFISHTRAP 1ST TEEL PKWYLEGACYPRAI R I E SITEHARPER RD. LEGEND (C.M.) - CONTROLLING MONUMENT IRF - IRON ROD FOUNDCIRF - CAPPED IRON ROD FOUND DOC.-DOCUMENTINST. - INSTRUMENTNO. - NUMBER D.R.D.C.T. - DEED RECORDS DENTON COUNTY, TEXASP.R.D.C.T. - PLAT RECORDS DENTON COUNTY TEXAS O.P.R.D.C.T. - OFFICIAL PUBLIC RECORDS DENTON COUNTY TEXAS NOTICE: SELLING A PORTION OF THIS ADDITION BY METES AND BOUNDS IS AVIOLATION OF TOWN ORDINANCE AND STATE LAW AND IS SUBJECT TO FINES AND WITHHOLDING OF UTILITIES AND BUILDING PERMITS. SURVEY NOTES: 1.ALL CORNERS ARE MARKED WITH A 5/8 INCH IRON ROD WITHCAP STAMPED “TNP”, UNLESS OTHERWISE NOTED. 2.BEARINGS ARE REFERENCED TO GRID NORTH OF THE TEXASCOORDINATE SYSTEM OF 1983 NORTH CENTRAL ZONE (4202) ASDERIVED LOCALLY FROM WESTERN DATA SYSTEMS CONTINUOUSLY OPERATING REFERENCE STATIONS (CORS) VIAREAL TIME KINEMATIC (RTK) SURVEY METHODS. ALL DISTANCES SHOWN ARE SURFACE DISTANCES USING ACOMBINED SCALE FACTOR OF 1.000150630. 3.BY GRAPHIC SCALE ONLY AND PER THE NATIONAL FLOODINSURANCE PROGRAM FLOOD INSURANCE RATE MAP FORDENTON COUNTY, TEXAS AND INCORPORATED AREAS, MAPNO. 48121C0430G, EFFECTIVE DATE: APRIL 18, 2011, THESUBJECT PROPERTY IS SHOWN TO BE LOCATED IN ZONE"X". THE LOCATION OF THE SAID FLOOD ZONES IS BASED ONSAID MAP AND IS APPROXIMATE AND IS NOT LOCATED ONTHE GROUND. THIS STATEMENT SHALL NOT CREATELIABILITY ON THE PART OF THE SURVEYOR. RELEVANTZONES ARE DEFINED AS FOLLOWS: ZONE "X" - OTHER AREAS: AREAS DETERMINED TO BEOUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN. 4. THE SURVEYOR, AS REQUIRED BY STATE LAW, IS RESPONSIBLEFOR SURVEYING INFORMATION ONLY AND BEARS NO RESPONSIBILITY FOR THE ACCURACY OF THE ENGINEERINGDATA ON THIS PLAT. 5.THE SURVEY ABSTRACT LINES, BEARINGS, AND DISTANCES SHOWN HEREON ARE APPROXIMATE AND ARE NOT LOCATEDON THE GROUND. OWNER PROSPER INDEPENDENT SCHOOL DISTRICT 605 East 7th Street Prosper, Texas 75078 Contact: Dr. Drew Watkins SURVEYOR TEAGUE NALL & PERKINS, INC. 825 Watters Creek Boulevard, Suite M300 Allen, Texas 75013 214.461.9867 ph 214.461.9864 fx T.B.P.L.S. Registration No. 10194381 www.tnpinc.com PROJECT INFORMATION Project No.: HUC 18414 Date:February 04, 2019 Drawn By:GS9 Scale:1"=100' SHEET 1 of 1 30.890 ACRES1,345,567 SQUARE FEET SITUATED IN THEL. NETHERLY SURVEY, ABSTRACT No. 962 Town of Prosper, Denton County, Texas CASE NO. D18-0132 FINAL PLAT PROSPER SCHOOL CHURCH ADDITION BLOCK A, LOT 1 OWNER'S CERTIFICATE STATE OF TEXAS § COUNTY OF DENTON § Being a tract of land situated in the Louisa Netherly Survey, Abstract Number 962, Denton County, Texas being all of Block A, Lot 1 of the Conveyance Plat of Prosper School Church Addition, an addition to The Town of Prosper as recorded in Document Number _________________ of the Official Public Records of Denton County, Texas same being all of six tracts of land by deed to Prosper Independent School District as recorded in Document Numbers 2018-150409, 2018-150426, 2018-150433, 2018-150443, 2018-150410, and 2018-450432 of the Official Public Records of Denton County, Texas and being more particularly described by metes and bounds as follows; BEGINNING at a 5/8 inch iron rod with cap stamped "Petitt" found lying on the east line of Artesia Phase 1A, anaddition to The Town of Prosper, Denton County, Texas as recorded in Cabinet X, Page 14 of the Official Public Records of Denton County, Texas for a southerly corner of a tract of land described by deed to Corona Artesia LLCcalled Tract VI as recorded in Document Number 208-34098 of the Official Public Records of Denton County, Texas said point also being the northwest corner said Lot 1; THENCE South 88 degrees 07 minutes 04 seconds East, along the south line of said Corona Artesia tract, passing a 5/8 inch iron rod with cap stamped "Petitt" found for the southeast corner of said Corona Artesia tract, same being the southwest corner line of a tract of land to Denton County Fresh Water Supply District No. 10 as recorded in Document Number 2006-144396 of the Official Public Records of Denton County, Texas at a distance of 1044.61 feet, and continuing along the south line of said Denton County Fresh Water tract, a total distance of 1047.57 feet to a 5/8 inch iron rod with cap stamped "Petitt" found for corner; THENCE South 89 degrees 18 minutes 53 seconds East continuing along the south line of said Denton County tract, a distance of 91.64 feet to a 5/8 inch iron rod with cap stamped "TNP" found for corner for the northeast corner of said Lot 1; THENCE South 00 degrees 30 minutes 44 seconds West, a distance of 1233.87 feet to a 5/8 inch iron rod with cap stamped "TNP" found for the southeast corner of said Lot 1, same being the southwest corner of Block A, Lot 2 of saidConveyance Plat and lying on the north line of Fishtrap road, (a variable width right-of-way); THENCE South 89 degrees 03 minutes 51 seconds West along the north line of said Fishtrap Road, same being thesouth line of said Lot 1, a distance of 792.73 feet to a 5/8 inch iron rod with cap stamped "TNP" found for the most southerly southwest corner of said Lot 1, same being the southeast corner of Block A, Lot 3 of said Conveyance Plat; THENCE along the common line of said Lot 1 and said Lot 3 the following courses and distances; North 00 degrees 52 minutes 46 seconds West, a distance of 254.18 feet to a 5/8 inch iron rod with cap stamped "TNP" found for corner; South 89 degrees 02 minutes 54 seconds West, a distance of 336.06 feet to a 5/8 inch iron rod with cap stamped "TNP" found for the most westerly southwest corner of said Lot 1, same being the northwest corner of said Lot 3 and lying on the aforementioned east line of said Artesia Phase 1A addition; THENCE North 00 degrees 16 minutes 24 seconds East along the east line of said Artesia Phase 1A addition, passing a wood cross tie fence post for reference at a distance of 1011.12 feet and continuing a total distance of 1033.71 feet to the POINT OF BEGINNING containing 1,345,567 square Feet, or 30.890 acres of land. NOW, THEREFORE, KNOW ALL MEN BY THESE PRESENTS: THAT PROSPER INDEPENDENT SCHOOL DISTRICT, acting herein by and through its duly authorized officers, does hereby certify and adopt this plat designating the herein above described property as PROSPER SCHOOL CHURCH ADDITION BLOCK A, LOT 1, an addition to the Town of Prosper, and does hereby dedicate to the public use forever, the streets and alleys shown thereon. Prosper Independent School District does herein certify the following: 1.The Streets and Alleys are dedicated for Street and Alley purposes. 2.All public improvements and dedications shall be free and clear of all debt, liens, and/or encumbrances. 3.The easements and public use areas, as shown and created by this plat, are dedicated for the public use forever for the purposes indicated on this plat. 4.No buildings, fences, trees, shrubs or other improvements or growths shall be constructed or placed upon, over or across the utility easements as shown, except that landscape improvements may be placed in landscape easements if approved by the Town of Prosper. 5.The Town of Prosper is not responsible for replacing any improvements in, under, or over any easements caused by maintenance or repair. 6.Utility easements may also be used for the mutual use and accommodation of all public utilities desiring to use or using the same unless the easement limits the use to particular utilities, said use by public utilities being subordinate to the public's and Town of Prosper's use thereof. 7.The Town of Prosper and public utilities shall have the right to remove and keep removed all or parts of any buildings, fences, trees, shrubs or other improvements or growths which may in any way endanger or interfere with the construction, maintenance, or efficiency of their respective systems in the easements. 8.The Town of Prosper and public utilities shall at all times have the full right of ingress and egress to or from their respective easements for the purpose of constructing, reconstructing, inspecting, patrolling, maintaining, reading meters, and adding to or removing all or parts of their respective systems without the necessity at any time procuring permission from anyone. 9.All modifications to this document shall be by means of plat and approved by the Town of Prosper. This plat is approved subject to all platting ordinances, rules, regulations and resolutions of the Town of Prosper, Texas. ACCESS EASEMENT The undersigned covenants and agrees that the access easement(s) may be utilized by any person or the general public for ingress and egress to other real property, and for the purpose of general public vehicular and pedestrian use and access, and for the Fire Department, Police, and emergency use in along, upon, and across said premises, with the right and privilege at all times of the Town of Prosper, its agents, employees, workmen, and representatives having ingress, egress, and regress in, along, upon, and across said premises. FIRE LANE EASEMENT The undersigned covenants and agrees that he (they) shall construct upon the fire lane easements, as dedicated and shown hereon, a hard surface paved in accordance with Town standards and that he (they) shall maintain the same in a state of good repair at all times and keep the same free and clear of any structures, fences, trees, shrubs, or other improvements or obstruction, including but not limited to the parking, loading, or unloading of motor vehicles, trailers, boats, or other impediments to the access of fire apparatus. The maintenance of pavement in accordance to Town standards of the fire lane easements is the responsibility of the owner, and the owner shall post and maintain signage in accordance to Town standards in conspicuous places along the fire lanes, stating “Fire Lane, No Parking”. The police or their duly authorized representative is hereby authorized to cause such fire lanes and utility easements to be maintained free and unobstructed at all times for fire department and emergency use. STREET EASEMENT The area or areas shown on the plat as “Street Easement” are hereby given and granted to the Town of Prosper (Called "Town") its successors andassigns, as an easement to construct, reconstruct, operate, repair, re-build, replace, relocate, alter, remove and perpetually maintain street and highway facilities, together with all appurtenances and incidental improvements, in, upon and across certain real property owned by Grantor. Appurtenances andincidental improvements include, but are not limited to, curbs, gutters, inlets, aprons, traffic signs with or without attached flashing lights, guard rails, sidewalks, buried conduits, buried City utilities, and underground franchise utilities. Street Easements shall remain accessible at all times and shall bemaintained by the Owners of the lot or lots that are traversed by, or adjacent to the Street Easement. After doing any work in connection with the construction, 81 operation or repair of the street and highway facilities, the Town shall restore the surface of the Street Easement as close to the condition in which it was found before such work was undertaken as is reasonably practicable, except for trees, shrubs and structures within the Street Easement that were removedas a result of such work. LANDSCAPE EASEMENT The undersigned covenants and agrees that the landscape easement and restrictions herein set forth shall run with the land and be binding on the owner(s)of the property in this subdivision, their successors and assigns, and all parties claiming by, through and under them. In the event a replat is requested on all or part of this property, the Town may require any similar or additional restrictions at its sole discretion. The sole responsibility for maintenance andreplacement of landscape materials thereof shall be borne by any 'homeowners' association hereafter established for the owners of lots in this subdivision and/or the owners of the individual lots within this subdivision. Such maintenance and replacement shall be in conformance with the requirements, standards,and specifications of the Town of Prosper, as presently in effect or as may be hereafter amended. This provision may be enforced by specific performance or by any other remedy allowed by law. This Landscape Easement shall be void of utilities and other elements unless otherwise approved on the plat. WITNESS, my hand, this the day of , 2019. BY: PROSPER INDEPENDENT SCHOOL DISTRICT Authorized Signature Printed Name and Title STATE OF TEXAS § COUNTY OF DENTON§ BEFORE ME, the undersigned, a Notary Public in and for The State of Texas, on this day personally appeared , known to me to be the person and officer whose name is subscribed to the foregoing instrument, and acknowledged to me that he executed the same for the purposes and considerations therein express and in the capacity therein stated. GIVEN UNDER MY HAND AND SEAL OF OFFICE this the day, of , 2019. Notary Public, State of Texas SURVEYOR'S CERTIFICATE KNOW ALL MEN BY THESE PRESENTS: That I, Brian J. Maddox, II, do hereby certify that I prepared this plat and the field notes made a part thereof from an actual and accurate survey of the land and that the corner monuments shown thereon were properly placed under my personal supervision, in accordance with the Subdivision regulations of the Town of Prosper, Texas. Dated this day, of , 2019. BRIAN J. MADDOX, II REGISTERED PROFESSIONAL LAND SURVEYOR No. 6659 825 Watters Creek Boulevard, Suite M300Allen, Texas 75013214.461.9867 ph 214.461.9864 fxT.B.P.L.S. Registration No. 10194381jmaddox@tnpinc.com STATE OF TEXAS § COUNTY OF COLLIN § BEFORE ME, the undersigned, a Notary Public in and for The State of Texas, on this day personally appeared Brian Maddox II, known to me to be the person and officer whose name is subscribed to the foregoing instrument, and acknowledged to me that he executed the same for the purposes and considerations therein express and in the capacity therein stated. GIVEN UNDER MY HAND AND SEAL OF OFFICE this the day, of , 2019. Notary Public, State of Texas PRELIMINARY THIS DOCUMENT SHALL NOT BE RECORDED FOR ANY PURPOSE AND SHALL NOT BE USED OR VIEWED OR RELIED UPON AS A FINAL SURVEY DOCUMENT PRELIMINARY, THIS DOCUMENT SHALL NOT BE RECORDEDFOR ANY PURPOSE AND SHALL NOT BE USED OR VIEWEDOR RELIED UPON AS A FINAL SURVEY DOCUMENT. CERTIFICATE OF APPROVAL Approved this day, of , 2019 by the Planning & Zoning Commission of the Town of Prosper, Texas. Development Services Department Engineering Department Town Secretary Page 1 of 1 To: Planning & Zoning Commission Item No. 3f From: Alex Glushko, AICP, Planning Manager Re: Planning & Zoning Commission Meeting – February 19, 2019 Agenda Item: Consider and act upon a Final Plat/Conveyance Plat for Sexton Farm and Ranch, Block A, Lots 1-3, on 58.9± acres, located on the north side of First Street, west of Coit Road. The property is zoned Agricultural (A). (D19-0010). Description of Agenda Item: The plat shows Lots 1 and 2 as Conveyance Plat lots and Lot 3 as a Final Plat lot. The purpose of this plat is to modify the lot lines to correspond with existing property ownership and to allow for the construction of a single family dwelling on Lot 3. Access will be provided from First Street. This request has been reviewed by the Planning, Engineering, Fire, and Building Inspections Departments. The Final Plat conforms to the Agricultural development standards. Attached Documents: 1. Location Map 2. Final Plat Town Staff Recommendation: Town staff recommends approval of the Conveyance Plat/Final Plat subject to: 1. Town staff approval of all additions and/or alterations to the easements and dedications on the Final Plat. Prosper is a place where everyone matters. PLANNING D19-0010 FIRST ST COIT RDHIDDEN LAKE DRSWEETWATER LNCROWN COLONY DREQUESTRIAN WAYCHAPEL HILL DRCYPRESS LAKE LN BRADFORD DR LONGMONT LN ARBOL WAY COUNTRY BROOK LN CHALK HI L L LAVACA LN ELM TERRACE LN HAWK WOOD LNSTONYBROOK DR LAKEMERE DR LA CIMA BLVDPLYMOUTH COLONY DRCROSS TIMBERS DR COUNTRY CREEK LN SANDSTONE DRTRAVIS LNGREENWOOD CT CHALK HILL LN SUNDANCE CTSALADA DRPOINT E R S D R HIDDEN FALLS CT SPRINGLAKE DR HIDDEN GLEN CT ±0 420 840210 Feet Page 1 of 1 To: Planning & Zoning Commission Item No. 3g From: Pamela Clark, Planning/GIS Specialist Through: Alex Glushko, AICP, Planning Manager Re: Planning & Zoning Commission Meeting – February 19, 2019 Agenda Item: Consider and act upon a Site Plan for a Sit-Down Restaurant (IHOP), on 1.4± acres, located on the north side of US 380, west of Coit Road. The property is zoned Planned Development-2 (PD-2). (D19-0011). Description of Agenda Item: The Site Plan shows a 3,700 square-foot sit-down restaurant (IHOP). Access is provided from US 380. Adequate parking has been provided. The Site Plan conforms to the PD-2 development standards. As a companion item, the Final Plat for Prosper Commons, Block B, Lot 3 (D19-0012) is on the February 19, 2019, agenda. Attached Documents: 1. Location Map 2. Site Plan Town Staff Recommendation: Town staff recommends approval of the Site Plan subject to: 1. Town staff approval of civil engineering, irrigation plans, open space plans, façade and address plans. 2. Town staff approval of all fire hydrants, fire department connections (FDC) and fire lanes, including widths, radii, and location. Prosper is a place where everyone matters. PLANNING UNIVERSITY DRPROSPER COMMONS BLVDCOIT RDRICHLAND BLVD D19-0011 ±0 210 420105 Feet C 1 IHOP Page 1 of 1 To: Planning & Zoning Commission Item No. 3h From: Pamela Clark, Planning/GIS Specialist Through: Alex Glushko, AICP, Planning Manager Re: Planning & Zoning Commission Meeting – February 19, 2019 Agenda Item: Consider and act upon a Final Plat for Prosper Commons, Block B, Lot 3, on 1.4± acres, located on the north side of US 380, west of Coit Road. The property is zoned Planned Development-2 (PD-2). (D19-0012). Description of Agenda Item: The Final Plat dedicates all easements necessary for development and conforms to the PD-2 development standards. As a companion item, the Site Plan for a sit-down restaurant, IHOP, (D19-0011), is on the February 19, 2019 agenda. Legal Obligations and Review: The Final Plat meets minimum development requirements. Attached Documents: 1. Location Map 2. Final Plat Town Staff Recommendation: Town staff recommends approval of the Final Plat, subject to: 1. Town staff approval of all additions and/or alterations to the easements and dedications on the Final Plat. Prosper is a place where everyone matters. PLANNING UNIVERSITY DRPROSPER COMMONS BLVDCOIT RDRICHLAND BLVD D19-0012 ±0 210 420105 Feet Page 1 of 1 To: Planning & Zoning Commission Item No. 3i From: Scott Ingalls, AICP, Senior Planner Through: Alex Glushko, AICP, Planning Manager Re: Planning & Zoning Commission Meeting – February 19, 2019 Agenda Item: Consider and act upon a Conveyance Plat for Prosper School Church Addition, Block A, Lots 1- 3, on 56.1± acres, located on the north side of Fishtrap Road, east of Teel Parkway. The property is zoned Agricultural (A). (D19-0013). Description of Agenda Item: The purpose of this Conveyance Plat is to create three (3) lots to accommodate future development of a PISD Middle School and a Town of Prosper elevated storage tank. The Conveyance Plat conforms to the Agricultural development standards. Prosper ISD is preparing a request for the Town Council to approve a quit claim for Harper Road, which is a prescriptive roadway, but has not been platted as right-of-way. The Town Council will take action upon the request at an upcoming Town Council meeting. As a companion item, the Final Plat for the Prosper School Church Addition, Block A, Lot 1 (D18-0132) is on the February 19, 2019 agenda. Attached Documents: 1. Location Map 2. Conveyance Plat Staff Recommendation: Staff recommends approval of the Conveyance Plat, subject to: 1. Town Council approval of a quit claim for the Harper Road prescriptive roadway. 2. Staff approval of all additions and/or alterations to the easements and dedications on the Conveyance Plat. Prosper is a place where everyone matters. PLANNING D19-0013 ±0 420 840210 Feet N.W. CORNERL. NETHERLEY SURVEY, ABSTRACT NO. 962 79 4 7 . 0 0 ' 60' R.O.W. DEDICATION CABINET X, PAGE 14 O.P.R.D.C.T.HUDSON LANE(50' RIGHT-OF-WAY)PALESTINE DRIVE(50' RIGHT-OF-WAY)LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 13 LOT 14 LOT 15 LOT 16 LOT 17 LOT 18 LOT 19 LOT 20 CORONA ARTESIA LLCTRACT VI 5.515 ACRESDOC. NO. 208-34098 O.P.R.D.C.T. LOT 13LOT 14LOT 15 LOT 16 LOT 17 LOT 18 ARTESIA PHASE 2C DOC. NO. 2014-20 O.P.R.D.C.T. CHURCH OF CELEBRATION METRO, INC. 16.486 ACRESDOC. NO. 2016-79355 O.P.R.D.C.T. DENTON COUNTY FRESHWATER SUPPLY DISTRICT NO. 10 2.461 ACRESDOC. NO. 2006-144396 O.P.R.D.C.T. 40 48 48 HA R P E R R O A D (50' R I G H T - O F - W A Y ) ARTESIA PHASE 1ACABINET X, PAGE 14 O.P.R.D.C.T. 5/8" CIRF"PETITT" 5/8" CIRF"PETITT" 5/8" CIRF"PETITT" 5/8" CIRF"PETITT" "X" CUTFOUND "X" CUTFOUND 1/2" IRF 1/2" IRF 1/2" IRF 1/2" IRF 5/8" CIRF"PETITT" 5/8" CIRF"PETITT" 5/8" CIRF"BGT" 5/8" CIRF"BGT" 5/8" CIRF"PETITT"5/8" CIRF"PETITT" 5/8" CIRF"PETITT" 5/8" CIRF"PETITT" 5/8" CIRF"PETITT" 5/8" CIRF"PETITT" 1/2" IRF 5/8" CIRF"PETITT" UTILITY EASEMENT DOC. NO. 2009-136113 O.P.R.D.C.T. POINT OF BEGINNING BLOCK A, LOT 1 30.890 ACRES1,345,567 SQUARE FEET 69.00'UTILITY EASEMENT DOC. NO. 2009-136113 O.P.R.D.C.T. APPROXIMATE LOCATION F.E.M.A. 100-YEAR FLOODPLAIN APPROXIMATE LOCATION F.E.M.A. 100-YEAR FLOODPLAIN APPROXIMATE LOCATION F.E.M.A. 100-YEAR FLOODPLAIN 5/8" CIRF"PETITT"5/8" CIRF "PETITT"FOR REFERENCE AT1044.61' WOOD CROSS TIE FENCE POSTFOR REFERENCE AT 1280.54' 1047.57' S 89°18'53" E91.64'434.14'367.97'624.08'S 01° 05' 01" ES 88° 07' 04" E S 89° 30' 46" E S 00° 05' 09" WS 00° 37' 56" WS 88° 54' 31" W 352.48' BOUNDARY LINE AGREEMENT INST. NO. _____________O.P.R.D.C.T. MAV PARTNERS, LLC TRACTS ONE, TWO & THREE DOC. NO. 2014-63637 R.P.R.D.C.T. BLUE STAR ALLEN LAND, L.P. 243.808 ACRES PARCEL IV DOC. NO. 2011-60030 R.P.R.D.C.T. LOT 1LOT 2LOT 3LOT 4 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 13 1X (HOA) 1X (HOA)CHAUCER DRIVE(50' RIGHT-OF-WAY)CLEARWATER DRIVE (50' RIGHT-OF-WAY) A B BPARKS AT LEGACY PHASE II DOC. NO. 2017-117 O.P.R.D.C.T.LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6LOT 14 LOT 15 LOT 16 LOT 17 LOT 18 LOT 19 GS 00°30'44" W19X (HOA)1X (HOA) PARKS AT LEGACY PHASE IDOC. NO. 2015-283 O.P.R.D.C.T. 928.49' S 88°54'43" W66.57' BLOCK A, LOT 3 1.918 ACRES83,540 SQUARE FEET S 88° 53' 35" W S 01° 05' 33" E203.70'S 00°30'44" W3.31' BLOCK A, LOT 2 22.539 ACRES981,816 SQUARE FEET 217.60'S 89° 23' 16" W 1233.87'S 89°02'54" W 336.06'1303.13'N 00°52'46" W254.18'N 00° 16' 24" ES 89° 02' 54" W 341.48' ZON E " A " THE TOWN OF PROSPER, TEXAS DOC. NO. ___________ O.P.R.D.C.T. BOUNDARY LINE AGREEMENTINST. NO. _____________ O.P.R.D.C.T. APPROXIMATE LOCATION F.E.M.A. 100-YEAR FLOODPLAIN 83.60'ZONE "X" ZON E " X " 692.24'269.42'CHURCH OF CELEBRATION METRO, INC. 12.800 ACRES DOC. NO. 2014-56866O.P.R.D.C.T. CHURCH OF CELEBRATION METRO, INC. 16.486 ACRES DOC. NO. 2016-79355 O.P.R.D.C.T.HARPER ROADPROSPER INDEPENDENT SCHOOL DISTRICT 8.920 ACRESDOC. NO. 2018-150409 O.P.R.D.C.T. PROSPER INDEPENDENT SCHOOL DISTRICT 0.330 ACRES DOC. NO. 2018-150410 O.P.R.D.C.T.PROSPER INDEPENDENT SCHOOL DISTRICT 1.000 ACRES DOC. NO. 2018-150426 O.P.R.D.C.T.PROSPER INDEPENDENT SCHOOL DISTRICT2.871 ACRESDOC. NO. 2018-150433O.P.R.D.C.T.PROSPER INDEPENDENT SCHOOL DISTRICT0.008 ACRES DOC. NO. 2018-150432O.P.R.D.C.T. PROSPER INDEPENDENT SCHOOL DISTRICT 18.076 ACRES DOC. NO. 2018-150443 O.P.R.D.C.T. PORTION OFHARPER ROAD TO BE ABANDONED BYTOWN OF PROSPER ORDINANCE NO.______________ APPROXIMATE LOCATION OF WATER LINE EASEMENT(NO DESCRIPTION IN DOCUMENT) DOC. NO. 2012-43648O.P.R.D.C.T. PORTION OF HARPER ROAD TO BE ABANDONED BYTOWN OF PROSPER ORDINANCE NO.______________ DENTON COUNTY FRESH WATER SUPPLY DISTRICT NO. 10 39.213 ACRES DOC. NO. 2014-7938O.P.R.D.C.T. FISHTRAP ROAD (VARIABLE WIDTH RIGHT-OF-WAY) 60' RIGHT-OF-WAY, VOLUME 228, PAGE 450, D.R.D.C.T. 5/8" CIRF "R.P.L.S. 4818" AT THE BASE OF A WOOD FENCE POST (C.M.) 2" IRON PIPE FOUND (C.M.) PREVIOUS DEED LINE PREVIOUS DEED LINE 5/8" CIRF "PETITT" 1/2" IRF (C.M.) DENTON COUNTY FRESH WATER SUPPLY DISTRICT NO. 10 39.213 ACRES DOC. NO. 2014-7938O.P.R.D.C.T. ZONE "A"1033.71'STREET EASEMENT 5'x20' DRAINAGE EASEMENT15' FIRELANE, ACCESS,DRAINAGE & UTILITYEASEMENT15' FIRELANE, ACCESS,DRAINAGE & UTILITYEASEMENT15' UTILITY EASEMENT15' UTILITY EASEMENT10' ACCESSEASEMENTSIDEWALK EASEMENT STREET EASEMENT 341.18' 523.52'N 89°03'51" EN 88°27'34" W L1L3L4 C1 C2 C6C5 L7 L6 L5C7998.76'C4C3L652.73'534.65'41.51'291.40'99.08'324.03'5'x20' DRAINAGE EASEMENT 23.08' 792.73'N 89°03'51" E 313.76' L8 17.22'VARIABLE WIDTH FIRELANE& UTILITY EASEMENT6.33' C8 L2 30.02'186.48'1230.56'RIGHT-OF-WAY DEDICATION DEDICATED IN FEE SIMPLE TO THE TOWN OF PROSPER 0.710 ACRES 30,901 SQUARE FEET L17L18L19L23L24L25L20L22L21L10L11 L14L15L16 C9C 1 0 C11 292.42'13.00' 20.48'4.88' 15.03'6.66' 55.13'44.77'40.28'FIRELANE, ACCESS, &UTILITY EASEMENT 36' DRAINAGEEASEMENT 12' DRAINAGE EASEMENT 15' SANITARY SEWEREASEMENT 12.00' 13.00' TWO-J PARTNERS, LLLP INST. NO. 2008-50523 O.P.R.D.C.T. N 4 9 ° 2 9 ' 1 6 " W SANITARY SEWER EASEMENTDOC. NO. 2018-88013O.P.R.D.C.T.EASEMENT LINE TABLE LINE # L1 L2 L3 L4 L5 L6 L6 L7 L8 L10 L11 L14 BEARING N44°03'51"E N00°56'09"W S00°56'09"E N89°03'51"E S00°30'44"W S48°01'41"E S00°30'44"W S48°01'41"E N89°03'51"E S01°05'33"E S88°54'43"W S01°05'01"E LENGTH 24.63' 241.37' 10.00' 100.00' 58.62' 20.02' 49.33' 40.03' 100.00' 222.60' 37.57' 126.70' EASEMENT LINE TABLE LINE # L15 L16 L17 L18 L19 L20 L21 L22 L23 L24 L25 BEARING S01°05'01"E S88°54'31"W S35°22'45"W S35°22'45"W N22°00'54"E N04°34'52"E N50°10'47"E N04°34'52"E N22°00'54"E N04°36'43"W N04°36'43"W LENGTH 24.00' 284.51' 403.93' 376.16' 207.75' 302.00' 9.87' 210.08' 207.68' 285.24' 279.58' LOT CURVE TABLE CURVE # C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 RADIUS 291.00' 269.00' 100.00' 100.00' 291.00' 269.00' 130.00' 30.00' 30.00' 30.00' 54.00' DELTA 10°50'39" 10°50'39" 19°31'27" 19°31'27" 10°50'39" 10°50'39" 27°47'45" 24°59'22" 89°59'44" 90°00'00" 38°06'26" ARC LENGTH 55.08' 50.91' 34.08' 34.08' 55.08' 50.91' 63.07' 13.08' 47.12' 47.12' 35.92' CHORD BEARING N 85°30'49" W S 85°30'49" E S 09°15'00" E S 09°15'00" E N 85°30'49" W S 85°30'49" E S 13°23'08" E N 13°25'50" W S 43°54'51" W S 46°05'01" E N 71°11'33" W CHORD LENGTH 54.99' 50.84' 33.91' 33.91' 54.99' 50.84' 62.45' 12.98' 42.42' 42.43' 35.26' 050 100100 SCALE IN FEET1" = 100'Drawing: L:\Projects\HUC 18414 PISD MS No 4 Ref-PPS 18400\Acad\Deliverables\Conveyance Plat\2019 02 01 HUC 18414 PISD MS-4 Convey Plat.dwg at Feb 01, 2019-11:30am by jmaddoxVICINITY MAP NOT TO SCALE NORTH FRISCO PROSPER 380 COUNTYLINEROADDALLAS NORTH TOLLWAYFISHTRAP 1ST TEEL PKWYLEGACYPRAI R I E SITE HARPER RD. LEGEND (C.M.) - CONTROLLING MONUMENTIRF - IRON ROD FOUND CIRF - CAPPED IRON ROD FOUNDDOC.-DOCUMENT INST. - INSTRUMENTNO. - NUMBER D.R.D.C.T. - DEED RECORDS DENTON COUNTY, TEXAS P.R.D.C.T. - PLAT RECORDS DENTON COUNTY TEXAS O.P.R.D.C.T. - OFFICIAL PUBLIC RECORDS DENTON COUNTY TEXAS NOTICE: SELLING A PORTION OF THIS ADDITION BY METES AND BOUNDS IS A VIOLATION OF TOWN ORDINANCE AND STATE LAW AND IS SUBJECT TO FINES AND WITHHOLDING OF UTILITIES AND BUILDING PERMITS. SURVEY NOTES: 1.ALL CORNERS ARE MARKED WITH A 5/8 INCH IRON ROD WITH CAPSTAMPED “TNP”, UNLESS OTHERWISE NOTED. 2.BEARINGS ARE REFERENCED TO GRID NORTH OF THE TEXAS COORDINATESYSTEM OF 1983 NORTH CENTRAL ZONE (4202) AS DERIVED LOCALLY FROM WESTERN DATA SYSTEMS CONTINUOUSLY OPERATING REFERENCE STATIONS (CORS) VIA REAL TIME KINEMATIC (RTK) SURVEY METHODS. ALL DISTANCES SHOWN ARE SURFACE DISTANCES USING A COMBINED SCALE FACTOR OF1.000150630. 3.BY GRAPHIC SCALE ONLY AND PER THE NATIONAL FLOOD INSURANCE PROGRAM FLOOD INSURANCE RATE MAP FOR DENTON COUNTY, TEXAS AND INCORPORATED AREAS, MAP NO. 48121C0430G, EFFECTIVE DATE: APRIL 18, 2011, THE SUBJECT PROPERTY IS SHOWN TO BE LOCATED INZONE "X". THE LOCATION OF THE SAID FLOOD ZONES IS BASED ON SAIDMAP AND IS APPROXIMATE AND IS NOT LOCATED ON THE GROUND. THISSTATEMENT SHALL NOT CREATE LIABILITY ON THE PART OF THESURVEYOR. RELEVANT ZONES ARE DEFINED AS FOLLOWS: ZONE "X" - OTHER AREAS: AREAS DETERMINED TO BE OUTSIDE THE0.2% ANNUAL CHANCE FLOODPLAIN. 4. THE SURVEYOR, AS REQUIRED BY STATE LAW, IS RESPONSIBLE FOR SURVEYING INFORMATION ONLY AND BEARS NO RESPONSIBILITY FOR THEACCURACY OF THE ENGINEERING DATA ON THIS PLAT. 5.THE SURVEY ABSTRACT LINES, BEARINGS, AND DISTANCES SHOWN HEREONARE APPROXIMATE AND ARE NOT LOCATED ON THE GROUND. NOTICE: A CONVEYANCE PLAT IS A RECORD OF PROPERTY APPROVED BY THE TOWN OFPROSPER, TEXAS, FOR THE PURPOSE OF SALE OR CONVEYANCE IN ITS ENTIRETY OR INTERESTS THEREON DEFINED. NO BUILDING PERMIT SHALL BE ISSUED NORPERMANENT PUBLIC UTILITY SERVICE PROVIDED UNTIL A FINAL PLAT IS APPROVED, FILED OF RECORD AND PUBLIC IMPROVEMENTS ACCEPTED IN ACCORDANCE WITH THE PROVISIONS OF THE SUBDIVISION ORDINANCE OF THE TOWN OF PROSPER. SELLING A PORTION OF THIS ADDITION BY METES AND BOUNDS IS A VIOLATION OF TOWN ORDINANCE AND STATE LAW AND IS SUBJECT TO FINES AND WITHHOLDING OF UTILITIES AND BUILDING PERMITS. 56.057 ACRES GROSS55.347 ACRES NET SITUATED IN THE L. NETHERLY SURVEY, ABSTRACT No. 962 Town of Prosper, Denton County, Texas CASE NO. D19-0013 CONVEYANCE PLAT PROSPER SCHOOL CHURCH ADDITION BLOCK A, LOTS 1, 2 & 3 OWNER THE TOWN OF PROSPER, TEXAS 200 South Main Prosper, Texas 75078 Contact: Pete Anaya Ph. (972) 346-2640 SURVEYOR TEAGUE NALL & PERKINS, INC. 825 Watters Creek Boulevard, Suite M300 Allen, Texas 75013 214.461.9867 ph 214.461.9864 fx T.B.P.L.S. Registration No. 10194381 www.tnpinc.com PROJECT INFORMATION Project No.: HUC 18414 Date:February 01, 2019 Drawn By:GS9 Scale:1"=100' SHEET 1 of 2 OWNER CHURCH OF CELEBRATION METRO, INC. 28691 Harper Road Prosper, Texas 75078 Contact: Deke Alexander Ph. (972) 822-9598 OWNER PROSPER INDEPENDENT SCHOOL DISTRICT 605 East 7th Street Prosper, Texas 75078 Contact: Dr. Drew Watkins OWNER'S CERTIFICATE STATE OF TEXAS § COUNTY OF DENTON § Being a tract of land situated in the Louisa Netherly Survey, Abstract Number 962, Denton County, Texas and being all of six tracts of land by deed to Prosper Independent School District as recorded in Document Numbers 2018-150409, 2018-150426, 2018-150433, 2018-150443, 2018-150410, and 2018-450432 ofthe Official Public Records of Denton County, Texas, all of a tract of land to the Town of Prosper as recorded in Document Number________________ of the Official Public Records of Denton County, Texas and a portion of two tracts of land to Church of Celebration Metrro, Inc. as recorded in Document Numbers 2014-56866 and 2016-79355 of the Official Public Records of Denton County, Texas and being more particularly described by metes and bounds as follows; BEGINNING at a 5/8 inch iron rod with cap stamped "Petitt" found lying on the east line of Artesia Phase 1A, an addition to the Town of Prosper, Denton County, Texas as recorded in Cabinet X, Page 14 of the Official Public Records of Denton County, Texas for a southerly corner of a tract of land described by deed to Corona Artesia LLC called Tract VI as recorded in Document Number 208-34098 of the Official Public Records of Denton County, Texas said point alsobeing the northwest corner of the herein described tract; THENCE South 88 degrees 07 minutes 04 seconds East, along the south line of said Corona Artesia tract, passing a 5/8 inch iron rod with cap stamped "Petitt" found for the southeast corner of said Corona Artesia tract, same being the southwest corner line of a tract of land to Denton County Fresh Water Supply District No. 10 as recorded in Document Number 2006-144396 of the Official Public Records of Denton County, Texas at a distance of 1044.61 feet, and continuing along the south line of said Denton County Fresh Water tract, a total distance of 1047.57 feet to a 5/8 inch iron rod with cap stamped "Petitt" found for corner; THENCE South 89 degrees 18 minutes 53 seconds East continuing along the south line of said Denton County tract, a distance of 91.64 feet to a 5/8 inch iron rod with cap stamped "TNP" found for corner; THENCE South 00 degrees 30 minutes 44 seconds West, a distance of 3.31 feet to a 5/8 inch iron rod with cap stamped "TNP" found for corner lying on thenorth line of said Church of Celebration tract recorded in 2014-56866; THENCE South 89 degrees 30 minutes 46 seconds East along the north line of said Church of Celebration tract recorded in 2014-56866, a distance of 928.49 feet to a 5/8 inch iron rod with cap stamped "R.P.L.S. 4818" found at the northeast base of a wood fence post for the northeast corner of same, lying on the west line of a tract of land to Blue Star Allen Land L.P. as recorded in Document Number 2011-60030 of the Official Public Records of Denton County, Texas, said point also being the northeast corner of the herein described tract; THENCE South 00 degrees 05 minutes 09 seconds West along the east line of said Church of Celebration tract recorded in 2014-56866, a distance of 434.14 feet to a 2 inch iron pipe found for the southeast corner of said Church of Celebration tract recorded in 2014-56866, same being the northeast corner of said Church of Celebration tract recorded in 2016-79355; THENCE South 00 degrees 37 minutes 56 seconds West along the east line of said Church of Celebration tract recorded in 2016-79355, a distance of 367.97 feet to a 5/8 inch iron rod with cap stamped "TNP" set for corner; THENCE departing the east line of said Church of Celebration tract recorded in 2016-79355 and through the interior of same the following courses and distances; South 88 degrees 54 minutes 31 seconds West, a distance of 352.48 feet to a 5/8 inch iron rod with cap stamped "TNP" set for corner; South 01 degrees 05 minutes 01 seconds East, a distance of 217.60 feet to a 5/8 inch iron rod with cap stamped "TNP" set for corner; South 88 degrees 54 minutes 43 seconds West, a distance of 66.57 feet to a 5/8 inch iron rod with cap stamped "TNP" set for corner; South 01 degrees 05 minutes 33 seconds East, a distance of 203.70 feet to a 5/8 inch iron rod with cap stamped "TNP" set for corner lying on the north line of Fishtrap road, (a variable width right-of-way) same being the south line of said Church of Celebration tract recorded in 2016-79355, said point also being thesoutheast corner of the herein described tract; THENCE South 88 degrees 53 minutes 35 seconds West along the north line of said Fishtrap Road, a distance of 624.08 feet to a 1/2 inch iron rod found forcorner; THENCE South 89 degrees 23 minutes 16 seconds West continuing along the north line of said Fishtrap Road, a distance of 692.24 feet to a 5/8 inch iron rod with cap stamped "TNP" set for corner; THENCE South 89 degrees 02 minutes 54 seconds West continuing along the north line of said Fishtrap Road, a distance of 341.48 feet to a 5/8 inch iron rod with cap stamped "TNP" set for the southwest corner of the herein described tract lying on the east line of the aforementioned Artesia Phase 1A addition; THENCE North 00 degrees 16 minutes 24 seconds East along the east line of said Artesia Phase 1A addition passing a wood cross tie fence post for reference at a distance of 1280.54 feet and continuing a total distance of, a distance of 1303.13 feet to the POINT OF BEGINNING containing 2,441,824 square feet, or 56.057 acres of land. NOW, THEREFORE, KNOW ALL MEN BY THESE PRESENTS: THAT PROSPER INDEPENDENT SCHOOL DISTRICT, CHURCH OF CELEBRATION METRO, INC., AND THE TOWN OF PROSPER, TEXAS, acting herein by and through its duly authorized officers, does hereby certify and adopt this plat designating the herein above described property as PROSPER SCHOOL CHURCH ADDITION, BLOCK A, LOTS 1, 2, AND 3, an addition to the Town of Prosper, and does hereby dedicate to the public use forever, the streets and alleys shown thereon. Prosper Independent School District does herein certify the following: 1.The Streets and Alleys are dedicated for Street and Alley purposes. 2.All public improvements and dedications shall be free and clear of all debt, liens, and/or encumbrances. 3.The easements and public use areas, as shown and created by this plat, are dedicated for the public use forever for the purposes indicated on this plat. 4.No buildings, fences, trees, shrubs or other improvements or growths shall be constructed or placed upon, over or across the utility easements as shown, except that landscape improvements may be placed in landscape easements if approved by the Town of Prosper. 5.The Town of Prosper is not responsible for replacing any improvements in, under, or over any easements caused by maintenance or repair. 6.Utility easements may also be used for the mutual use and accommodation of all public utilities desiring to use or using the same unless the easement limits the use to particular utilities, said use by public utilities being subordinate to the public's and Town of Prosper's use thereof. 7.The Town of Prosper and public utilities shall have the right to remove and keep removed all or parts of any buildings, fences, trees, shrubs or other improvements or growths which may in any way endanger or interfere with the construction, maintenance, or efficiency of their respective systems in the easements. 8.The Town of Prosper and public utilities shall at all times have the full right of ingress and egress to or from their respective easements for the purpose of constructing, reconstructing, inspecting, patrolling, maintaining, reading meters, and adding to or removing all or parts of their respective systems without the necessity at any time procuring permission from anyone. 9.All modifications to this document shall be by means of plat and approved by the Town of Prosper. This plat is approved subject to all platting ordinances, rules, regulations and resolutions of the Town of Prosper, Texas. ACCESS EASEMENT The undersigned covenants and agrees that the access easement(s) may be utilized by any person or the general public for ingress and egress to other real property, and for the purpose of general public vehicular and pedestrian use and access, and for the Fire Department, Police, and emergency use in along, upon, and across said premises, with the right and privilege at all times of the Town of Prosper, its agents, employees, workmen, and representatives having ingress, egress, and regress in,long, upon, and across said premises. FIRE LANE EASEMENT The undersigned covenants and agrees that he (they) shall construct upon the fire lane easements, as dedicated and shown hereon, a hard surface paved in accordance with Town standards and that he (they) shall maintain the same in a state of good repair at all times and keep the same free and clear of any structures, fences, trees, shrubs, or other improvements or obstruction, including but not limited to the parking, loading, or unloading of motor vehicles, trailers, boats, or other impediments to the access of fire apparatus. The maintenance of pavement in accordance to Town standards of the fire lane easements is the responsibility of the owner, and the owner shall post and maintain signage in accordance to Town standards in conspicuous places along the fire lanes, stating “Fire Lane, No Parking”. The police or their dulyauthorized representative is hereby authorized to cause such fire lanes and utility easements to be maintained free and unobstructed at all times for fire department and emergency use. STREET EASEMENT The area or areas shown on the plat as “Street Easement” are hereby given and granted to the Town of Prosper (Called "Town") its successors and assigns, as an easement to construct, reconstruct, operate, repair, re-build, replace, relocate, alter, remove and perpetually maintain street and highway facilities, together with all appurtenances and incidental improvements, in, upon and across certain real property owned by Grantor. Appurtenances and incidental improvements include, but arenot limited to, curbs, gutters, inlets, aprons, traffic signs with or without attached flashing lights, guard rails, sidewalks, buried conduits, buried City utilities, and underground franchise utilities. Street Easements shall remain accessible at all times and shall be maintained by the Owners of the lot or lots that are traversed by, or adjacent to the Street Easement. After doing any work in connection with the construction, 81 operation or repair of the street and highway facilities, the Town shallrestore the surface of the Street Easement as close to the condition in which it was found before such work was undertaken as is reasonably practicable, except for trees, shrubs and structures within the Street Easement that were removed as a result of such work. LANDSCAPE EASEMENT The undersigned covenants and agrees that the landscape easement and restrictions herein set forth shall run with the land and be binding on the owner(s) of the property in this subdivision, their successors and assigns, and all parties claiming by, through and under them. In the event a replat is requested on all or part of this property, the Town may require any similar or additional restrictions at its sole discretion. The sole responsibility for maintenance and replacement of landscape materials thereof shall be borne by any 'homeowners' association hereafter established for the owners of lots in this subdivision and/or the owners of the individual lots within thissubdivision. Such maintenance and replacement shall be in conformance with the requirements, standards, and specifications of the Town of Prosper, as presently in effect or as may be hereafter amended. This provision may be enforced by specific performance or by any other remedy allowed by law. This Landscape Easement shall be void of utilities and other elements unless otherwise approved on the plat. WITNESS, my hand, this the day of , 2019. BY: PROSPER INDEPENDENT SCHOOL DISTRICT Authorized Signature Printed Name and Title STATE OF TEXAS § COUNTY OF DENTON§ BEFORE ME, the undersigned, a Notary Public in and for The State of Texas, on this day personally appeared , known to me to be the person and officer whose name is subscribed to the foregoing instrument, and acknowledged to me that he executed the same for the purposes and considerations therein express and in the capacity therein stated. GIVEN UNDER MY HAND AND SEAL OF OFFICE this the day, of , 2019. Notary Public, State of Texas WITNESS, my hand, this the day of , 2019. BY: CHURCH OF CELEBRATION METRO, INC. Authorized Signature Printed Name and Title STATE OF TEXAS § COUNTY OF DENTON§ BEFORE ME, the undersigned, a Notary Public in and for The State of Texas, on this day personally appeared , known to me to be the person and officer whose name is subscribed to the foregoing instrument, and acknowledged to me that he executed the same for the purposes and considerations therein express and in the capacity therein stated. GIVEN UNDER MY HAND AND SEAL OF OFFICE this the day, of , 2019. Notary Public, State of Texas WITNESS, my hand, this the day of , 2019. BY: THE TOWN OF PROSPER, TEXAS Authorized Signature Printed Name and Title STATE OF TEXAS § COUNTY OF DENTON§ BEFORE ME, the undersigned, a Notary Public in and for The State of Texas, on this day personally appeared , known to me to be the person and officer whose name is subscribed to the foregoing instrument, and acknowledged to me that he executed the same for the purposes and considerations therein express and in the capacity therein stated. GIVEN UNDER MY HAND AND SEAL OF OFFICE this the day, of , 2019. Notary Public, State of Texas SURVEYOR'S CERTIFICATE KNOW ALL MEN BY THESE PRESENTS: That I, Brian J. Maddox, II, do hereby certify that I prepared this plat and the field notes made a part thereof from an actual and accurate survey of the land and that the corner monuments shown thereon were properly placed under my personal supervision, in accordance with the Subdivision regulations of the Town of Prosper, Texas. Dated this day, of , 2019. BRIAN J. MADDOX, II REGISTERED PROFESSIONAL LAND SURVEYOR No. 6659 825 Watters Creek Boulevard, Suite M300Allen, Texas 75013214.461.9867 ph 214.461.9864 fxT.B.P.L.S. Registration No. 10194381jmaddox@tnpinc.com STATE OF TEXAS § COUNTY OF COLLIN § BEFORE ME, the undersigned, a Notary Public in and for The State of Texas, on this day personally appeared , known to me to be the person and officer whose name is subscribed to the foregoing instrument, and acknowledged to me that he executed the same for the purposes and considerations therein express and in the capacity therein stated. GIVEN UNDER MY HAND AND SEAL OF OFFICE this the day, of , 2019. Notary Public, State of Texas Drawing: L:\Projects\HUC 18414 PISD MS No 4 Ref-PPS 18400\Acad\Deliverables\Conveyance Plat\2019 02 01 HUC 18414 PISD MS-4 Convey Plat.dwg at Feb 01, 2019-11:30am by jmaddoxPRELIMINARY THIS DOCUMENT SHALL NOT BE RECORDED FOR ANY PURPOSE AND SHALL NOT BE USED OR VIEWED OR RELIED UPON AS A FINAL SURVEY DOCUMENT PRELIMINARY, THIS DOCUMENT SHALL NOT BE RECORDEDFOR ANY PURPOSE AND SHALL NOT BE USED OR VIEWEDOR RELIED UPON AS A FINAL SURVEY DOCUMENT. SURVEYOR TEAGUE NALL & PERKINS, INC. 825 Watters Creek Boulevard, Suite M300 Allen, Texas 75013 214.461.9867 ph 214.461.9864 fx T.B.P.L.S. Registration No. 10194381 www.tnpinc.com PROJECT INFORMATION Project No.: HUC 18414 Date:February 01, 2019 Drawn By:GS9 Scale:1"=100' SHEET 2 of 2 CERTIFICATE OF APPROVAL Approved this day, of , 2019 by the Planning & Zoning Commission of the Town of Prosper, Texas. Development Services Department Engineering Department Town Secretary VICINITY MAP NOT TO SCALE NORTH FRISCO PROSPER 380 COUNTYLINEROADDALLAS NORTH TOLLWAYFISHTRAP 1ST TEEL PKWYLEGACYPRAI R I E SITE HARPER RD.56.057 ACRES GROSS 55.347 ACRES NET SITUATED IN THE L. NETHERLY SURVEY, ABSTRACT No. 962 Town of Prosper, Denton County, Texas CASE NO. D19-0013 CONVEYANCE PLAT PROSPER SCHOOL CHURCH ADDITION BLOCK A, LOTS 1, 2 & 3 OWNER THE TOWN OF PROSPER, TEXAS 200 South Main Prosper, Texas 75078 Contact: Pete Anaya Ph. (972) 346-2640 OWNER CHURCH OF CELEBRATION METRO, INC. 28691 Harper Road Prosper, Texas 75078 Contact: Deke Alexander Ph. (972) 822-9598 OWNER PROSPER INDEPENDENT SCHOOL DISTRICT 605 East 7th Street Prosper, Texas 75078 Contact: Dr. Drew Watkins Page 1 of 1 To: Planning & Zoning Commission Item No. 3j From: Alex Glushko, AICP, Planning Manager Re: Planning & Zoning Commission Meeting – February 19, 2019 Agenda Item: Consider and act upon a Site Plan for a Bank with Drive-Through (Farmers Bank & Trust), on 1.0± acre, located on the east side of Preston Road, south of Prosper Trail. The property is zoned Retail (R). (D19-0016). Description of Agenda Item: The Site Plan shows a 5,061 square-foot bank with drive-through (Farmers Bank & Trust). Access is provided from Preston Road. Adequate parking and stacking have been provided. The Site Plan conforms to the Retail development standards. As a companion item, the Final Plat for North Preston Village, Block A, Lot 3 (D19-0017) is on the February 19, 2019, agenda. Attached Documents: 1. Location Map 2. Site Plan Town Staff Recommendation: Town staff recommends approval of the Site Plan subject to: 1. Town staff approval of civil engineering, irrigation plans, open space plans, façade and address plans. 2. Town staff approval of all fire hydrants, fire department connections (FDC) and fire lanes, including widths, radii, and location. Prosper is a place where everyone matters. PLANNING D19-0016 HAYS RDPRESTON RDHIGHPOINT DR PRESTONVIEW DR PASEWARK CIR HICKORY CREEK DR PRESTON RD±0 140 28070 Feet Scale: 1"=20' February, 2019 SEI Job No. 18-227 Town Case No. D19-0016                SITE PLAN             NORTH PRESTON VILLAGE BLOCK A, LOT 3 IN THE TOWN OF PROSPER, COLLIN COUNTY, TEXAS J. TUNNEY SURVEY, ABST. NO. 916 41,735 Sq. Ft./ 0.958 Acres Current Zoning: R (Retail) OWNER BG-GBT North Preston Village, LP 9550 John W. Elliott Dr., Suite 106 Frisco, TX 75033 Telephone: (214) 972-0808 Contact: Ryan Griffin ENGINEER / SURVEYOR Spiars Engineering, Inc. 765 Custer Road, Suite 100 Plano, TX 75075 Telephone: (972) 422-0077 TBPE No. F-2121 Contact: David Bond LOCATION MAP 1" = 1000' PROJECT LOCATION APPLICANT Level 5 301 Fayetteville St., Unit 2607 Raleigh, NC 27601 Telephone (919) 614-7337 Contact: Chris Small Cab. 2017, Pg. 743 PRCCT Cab. 2017, Pg. 912 PRCCT Cab. 2017, Pg. 912 PRCCTVariable width R.O.W. Page 1 of 1 To: Planning & Zoning Commission Item No. 3k From: Alex Glushko, AICP, Planning Manager Re: Planning & Zoning Commission Meeting – February 19, 2019 Agenda Item: Consider and act upon a Final Plat for North Preston Village, Block A, Lot 3, on 1.0± acre, located on the east side of Preston Road, south of Prosper Trail. The property is zoned Retail (R). (D19-0017). Description of Agenda Item: The Final Plat dedicates all easements necessary for development and conforms to the Retail development standards. As a companion item, the Site Plan for a bank with drive-through, Farmers Bank & Trust, (D19- 0016), is on the February 19, 2019 agenda. Legal Obligations and Review: The Final Plat meets minimum development requirements. Attached Documents: 1. Location Map 2. Final Plat Town Staff Recommendation: Town staff recommends approval of the Final Plat, subject to: 1. Town staff approval of all additions and/or alterations to the easements and dedications on the Final Plat. Prosper is a place where everyone matters. PLANNING D19-0017 HAYS RDPRESTON RDHIGHPOINT DR PRESTONVIEW DR PASEWARK CIR HICKORY CREEK DR PRESTON RD±0 140 28070 Feet Doc. No. 2018-840 PRCCT Doc. No. 2017- 912 PRCCT Doc. No. 2017- 912 PRCCT Lot 3, Block A POINT OF BEGINNING variable width R.O.W.(also known as State Highway 289)Line Table H TRON                FINAL PLAT                NORTH PRESTON VILLAGE LOT 3, BLOCK A BEING 0.958 ACRES IN THE J. TUNNEY SURVEY, ABSTRACT NO. 916 TOWN OF PROSPER, COLLIN COUNTY, TEXAS CASE NO. D19-0017 Scale: 1" = 20' February, 2019 SEI Job No. 18-227 SURVEYOR'S CERTIFICATE STATE OF TEXAS §COUNTY OF COLLIN § OWNER'S CERTIFICATESTATE OF TEXAS §COUNTY OF COLLIN § WHEREAS ” “” “” “” “” “” ” “” NOTES: OWNER / APPLICANT BG-GBT North Preston Village LP 9550 John W. Elliott Dr., Ste. 106 Frisco, Texas 75033 Telephone (214) 972-0808 Contact: Ryan Griffin LEGEND 1/2" IRON ROD WITH PLASTIC CAP STAMPED "SPIARSENG" SET, UNLESS OTHERWISE NOTED IRON ROD FOUND CAPPED IRON ROD FOUND ALUMINUM MONUMENT FOUND CONTROL MONUMENT EASEMENT UTILITY BY THIS PLAT RIGHT-OF-WAY CABINET VOLUME PAGE NUMBER ORDINANCE NUMBER INSTRUMENT OR DOCUMENT DEED RECORDS, COLLIN COUNTY, TEXAS PLAT RECORDS, COLLIN COUNTY, TEXAS OFFICIAL PUBLIC RECORDS, COLLIN COUNTY, TEXAS ENGINEER / SURVEYOR Spiars Engineering, Inc. 765 Custer Road, Suite 100 Plano, TX 75075 Telephone: (972) 422-0077 TBPE No. F-2121 / TBPLS No. F-10043100 Contact: David Bond LOCATION MAP 1" = 1000' PROJECT LOCATION NOW THEREFORE, KNOW ALL MEN BY THESE PRESENTS: BG-GBT North Preston Village NORTH PRESTON VILLAGE ADDITION, Lot 3, Block A STATE OF TEXAS §COUNTY OF COLLIN § TOWN APPROVAL Page 1 of 2 To: Planning & Zoning Commission Item No. 4 From: Pamela Clark, Planning/GIS Specialist Through: Alex Glushko, AICP, Planning Manager Re: Planning & Zoning Commission Meeting – February 19, 2019 Agenda Item: Consider and act upon a request for a Façade Exception for 7-Eleven in Victory at Frontier, located on the southwest corner of Preston Road and Frontier Parkway. (MD19-0001). Description of Agenda Item: The applicant is seeking a Façade Exception for a 6,487 square-foot convenience store and restaurant with gas pumps, in order to allow for the use of an alternative primary building material (Porcelain Tile) and to allow for an increased percentage of permitted secondary materials. A table detailing the existing and proposed request is as follows: Primary Material Required Primary Material Provided (Stone) Porcelain Tile Proposed Secondary Material Permitted Secondary Material Provided (Metal & Wood) North 90% 29% 60% 10% 11% South 90% 25% 64% 10% 11% East 90% 20% 63% 10% 17% West 90% 17% 72% 10% 11% In considering an exception to the required masonry requirements, the Planning & Zoning Commission and Town Council may consider whether a proposed alternate material: (a) is a unique architectural expression; (b) includes unique building styles and materials; (c) is consistent with high quality development; (d) is or would be visually harmonious with existing or proposed nearby buildings; (e) has obvious merit based upon the quality and durability of the materials; and (f) represents an exterior building material that is in keeping with the intent of this chapter to balance the above-mentioned objectives. The applicant has provided a letter outlining how they have satisfied the criteria, which is attached for review. Prosper is a place where everyone matters. PLANNING Page 2 of 2 Attachments: 1. Location Map 2. Façade Plan 3. Building Rendering 4. Porcelain Tile Information Sheet 5. Site Plan 6. Criteria Response Letter Town Staff Recommendation: Town staff recommends that the Planning & Zoning Commission consider and act upon a request for a façade exception for 7-Eleven in Victory at Frontier, located on the southwest corner of Preston Road and Frontier Parkway. Town Council Consideration: Upon a recommendation by the Planning & Zoning Commission, this request will be scheduled for the Town Council meeting on March 12, 2019. MD19-0001 FRONTIER PKWY PRESTON RDPRESTON RD±0 170 34085 Feet +0'-0"FIN. FLR+17'-0"T.O. ROOF+22'-0"T.O. LOWER PARAPET+13'-2"T.O. STOREFRONT+8'-6"B.O. CANOPYPORCELAIN TILEPRE-FINISHED METALPARAPET CAPDARK WARM GRAYMETAL-CLAD BEAMSDECORATIVE SLATS INWOOD-LOOK; ALT. OPTION: IPEWOOD RAINSCREENPER MASTER DEVELOPMENT SPECENGINEERED STONEPLANTER BOXESENGINEERED STONEBASEDECORATIVE SLATS IN WOOD-LOOK,BEHIND BUTT-JOINT STOREFRONTGLAZINGSTOREFRONT SYSTEMENGINEERED STONESILLEXCSM-2EXCSM-1EXCSM-1EXSM-1EXWT-2PORCELAIN TILEEXWT-3EXPC-11EXPC-11PT-8PARTIAL HEIGHTWALL BEHINDGLAZING & SLATSPT-8PARTIAL HEIGHT WALLBEHIND GLAZING & SLATSENGINEERED STONESILLEXCSM-2PORCELAIN TILEEXWT-3PORCELAIN TILEEXWT-4STOREFRONT SYSTEMENGINEERED STONEBASEEXCSM-1ENGINEERED STONESILLEXCSM-2ENGINEERED STONEPLANTER BOXESEXCSM-1PORCELAIN TILEEXWT-2ENGINEERED STONEBASEEXCSM-1PORCELAIN TILEEXWT-3EXWT-1PORCELAIN TILEEXWT-4WOOD-LOOK PORCELAIN TILEALT: IPE WOOD RAINSCREENPER MASTER DEVELOPMENTSPECEXWT-1WOOD-LOOK PORCELAIN TILEALT: IPE WOOD RAINSCREENPER MASTER DEVELOPMENTSPEC120'-5"29'-10"30'-2"20'-11"3'-0"26'-5"13'-2"METAL CANOPYEXPC-11METAL CANOPYEXPC-1112'-6"+25'-6"T.O. UPPER PARAPET+0'-0"FIN. FLR+17'-0"T.O. ROOF+22'-0"T.O. LOWER PARAPET+13'-2"T.O. STOREFRONTENGINEERED STONESILLEXCSM-2PORCELAIN TILEEXWT-3ENGINEERED STONEBASEEXCSM-1PORCELAIN TILEEXWT-2PORCELAIN TILEEXWT-3PORCELAIN TILEEXWT-4PORCELAIN TILEEXWT-2DECORATIVE SLATS INWOOD-LOOK; ALT. OPTION: IPEWOOD RAINSCREEN PER MASTERDEVELOPMENT SPECEXSM-1DARK WARM GRAYMETAL-CLAD BEAMSEXPC-11STOREFRONT SYSTEMENGINEERED STONEPLANTER BOXESEXCSM-1PORCELAIN TILEEXWT-2PORCELAIN TILEEXWT-3DECORATIVE SLATS IN WOOD-LOOK;ALT. OPTION: IPE WOOD RAINSCREENPER MASTER DEVELOPMENT SPECEXSM-1ENGINEERED STONEPLANTER BOXESEXCSM-1WOOD-LOOKPORCELAIN TILEALT: IPE WOODRAINSCREENPER MASTERDEVELOPMENT SPECEXWT-159'-4"18'-4"1'-6"28'-5"1'-6"9'-10"3'-0"3'-0"ENGINEERED STONEBASEEXCSM-1ENGINEERED STONESILLEXCSM-2DARK WARM GRAYMETAL-CLAD CAPEXPC-11DARK WARM GRAYMETAL-CLAD CAPEXPC-11+25'-6"T.O. UPPER PARAPETOPEN BETWEEN SLATSOPEN BETWEEN SLATSENGINEERED STONEBASEEXCSM-1ENGINEERED STONESILLEXCSM-2+8'-0"T.O. ENCLOSUREENGINEERED STONEBASEEXCSM-115'-0"ELEVATIONAREASMATERIALSTOTALNETGLAZING/DOORSMETALSTONETILEWOODFRONT (EAST)LEFT (SOUTH)BACK (WEST)RIGHT (NORTH)PATIO2918.8 SF1187.5 SF, 40%1731.3 SF146.4 SF8%345.7 SF20%1092.2 SF63%147.0 SF9%1534.3 SF94.9 SF, 7%1439.4 SF93.6 SF7%417.6 SF29%865.9 SF60%62.3 SF4%2933.7 SF265.9 SF, 9%2667.8 SF136.8 SF5%460.3 SF17%1915.5 SF72%155.2 SF6%1529.6 SF27.5 SF, 2%1502.1 SF69.4 SF5%377 SF25%966.8 SF64%88.9 SF6%MATERIAL DISTRIBUTION(EXSM-1)(WT-1,2,3,4)(EXCSM-1,2)(EXPC-11)COPYRIGHT NOTICE:These drawings and specifications are copyrighted andsubject to copyright protection as an "architectural work"under sec. 102 of the copyright act, 17 U.S.C. As amendedJanuary 2003. The protection includes, without limitation,the overall form, arrangement and composition of spaces,and elements of the design. Under such protection,unauthorized use of these drawings and specifications mayresult in cessation of construction, building seizure, and / ormonetary liability.16435 North Scottsdale Rd. Suite 195Scottsdale, Arizona 85254T+1 480 998 4200 F+1 480 998 7223www. .comAAD:FITCH, Inc.STORE EVOLUTION TEAM - STORE 2NORTH PRESTON & FRONTIER PKWYPROSPER, TX 75078DATE:SHEET:2019-02-05SCALE:DRAWN BY:PROJECT NUMBER:320108463-AS NOTEDVICTORY AT FRONTIER,BLOCK A, LOT 2.TOWN PROJECT NUMBERPREPARATION DATED18-0127/ D19-0061EAST ELEVATION - FRONT3/32" : 1'-0"2NORTH ELEVATION - SIDE3/32" : 1'-0"NOTE:·THIS FACADE PLAN IS FOR CONCEPTUAL PURPOSES ONLY. ALLBUILDING PLANS REQUIRE REVIEW AND APPROVAL FROM THEBUILDING INSPECTIONS DEPARTMENT.·ALL MECHANICAL EQUIPMENT SHALL BE SCREENED FROM PUBLICVIEW. ROOFTOP MOUNTED EQUIPMENT SHALL BE SCREED BY APARAPET WALL OR SCREENING WALL. SCREENING WALLS SHALL BETHE SPECIFICATIONS OF THE ZONING ORDINANCE.·WHEN PERMITTED, EXPOSED UTILITY BOXES AND CONDUITS SHALLBE PAINTED TO MATCH THE BUILDING.·ALL SIGNAGE AREAS AND LOCATIONS ARE SUBJECT TO APPROVALBY THE BUILDING INSPECTIONS DEPARTMENT.·WINDOWS SHALL HAVE A MAXIMUM EXTERIOR VISIBLE REFLECTIVITYOF TEN (10) PERCENT.·ANY DEVIATION FROM THE APPROVED FACADE PLAN WILL REQUIRERE-APPROVAL BY THE TOWN OF PROSPER.AEE-1 +0'-0"FIN. FLR+17'-0"T.O. ROOF+8'-6"B.O. CANOPYPORCELAIN TILEEXWT-4PORCELAIN TILEEXWT-2PORCELAIN TILEEXWT-3PORCELAIN TILEEXWT-4DARK WARM GRAYMETAL-CLAD BEAMSEXPC-11ENGINEERED STONESILLEXCSM-2PORCELAIN TILEEXWT-3ENGINEERED STONEBASEEXCSM-1ENGINEERED STONESILLEXCSM-2ENGINEERED STONEBASEEXCSM-1ENGINEERED STONESILLEXCSM-2ENGINEERED STONEBASEEXCSM-1PORCELAIN TILEEXWT-2DARK WARM GRAYMETAL-CLAD BEAMSEXPT-2DECORATIVE SLATS IN WOOD-LOOK;ALT. OPTION: IPE WOOD RAINSCREENPER MASTER DEVELOPMENT SPECEXSM-1ENGINEERED STONEPLANTER BOXESEXCSM-1PAINTED METAL DOORPT-9PAINTED METAL DOORPT-9WOOD-LOOK PORCELAIN TILEALT: IPE WOOD RAINSCREENPER MASTER DEVELOPMENTSPECEXWT-1WOOD-LOOK PORCELAIN TILEALT: IPE WOOD RAINSCREENPER MASTER DEVELOPMENTSPECEXWT-1120'-5"3'-0"15'-3"1'-6"31'-0"DARK WARM GRAYMETAL-CLAD CAPEXPC-1114'-0"1'-6"1'-6"20'-5"1'-10"23'-10"+22'-0"T.O. LOWER PARAPET+25'-6"T.O. UPPER PARAPET+8'-0"T.O. ENCLOSUREPAINTED METALGATESEXPT-2PORCELAIN TILEEXWT-4DARK WARM GRAYMETAL-CLAD CAPEXPC-11DECORATIVE SLATS INWOOD-LOOK; ALT. OPTION: IPEWOOD RAINSCREENPER MASTER DEVELOPMENT SPECEXSM-112'-6"+0'-0"FIN. FLREXCSM-2ENGINEERED STONESILLENGINEERED STONESILLPORCELAIN TILEEXWT-3ENGINEERED STONEBASEEXCSM-1EXCSM-1EXCSM-2PORCELAIN TILEEXWT-3ENGINEERED STONEBASEEXCSM-1PAINTED METAL DOORENGINEERED STONEPLANTER BOXESPT-959'-4"3'-0"3'-0"19'-0"1'-6"17'-9"14'-9"6'-4"+17'-0"T.O. ROOFPORCELAIN TILEEXWT-4PORCELAIN TILEEXWT-2WOOD-LOOKPORCELAIN TILEEXWT-1DARK WARM GRAYMETAL-CLAD BEAMSEXPC-11DARK WARM GRAYMETAL-CLAD BEAMSEXPC-11DECORATIVE SLATS IN WOOD-LOOK;ALT. OPTION: IPE WOOD RAINSCREENPER MASTER DEVELOPMENT SPEC;OPEN BETWEEN SLATSEXSM-1DARK WARM GRAYMETAL-CLAD BEAMSEXPC-11EXTERIOR SIGNAGEBY SIGN CONTRACTOR.SEPARATE PERMIT.DECORATIVE SLATS IN WOOD-LOOK;ALT. OPTION: IPE WOOD RAINSCREENPER MASTER DEVELOPMENT SPECEXSM-1WOOD-LOOK PORCELAIN TILEALT: IPE WOOD RAINSCREENPER MASTER DEVELOPMENTSPECEXWT-1+22'-0"T.O. LOWER PARAPET+25'-6"T.O. UPPER PARAPET+8'-0"T.O. ENCLOSUREENGINEERED STONEBASEEXCSM-1DARK WARM GRAYMETAL-CLAD CAPEXPC-1115'-0"OPEN BETWEEN SLATSOPEN BETWEEN SLATSELEVATIONAREASMATERIALSTOTALNETGLAZING/DOORSMETALSTONETILEWOODFRONT (EAST)LEFT (SOUTH)BACK (WEST)RIGHT (NORTH)PATIO2918.8 SF1187.5 SF, 40%1731.3 SF146.4 SF8%345.7 SF20%1092.2 SF63%147.0 SF9%1534.3 SF94.9 SF, 7%1439.4 SF93.6 SF7%417.6 SF29%865.9 SF60%62.3 SF4%2933.7 SF265.9 SF, 9%2667.8 SF136.8 SF5%460.3 SF17%1915.5 SF72%155.2 SF6%1529.6 SF27.5 SF, 2%1502.1 SF69.4 SF5%377 SF25%966.8 SF64%88.9 SF6%MATERIAL DISTRIBUTION(EXSM-1)(WT-1,2,3,4)(EXCSM-1,2)(EXPC-11)COPYRIGHT NOTICE:These drawings and specifications are copyrighted andsubject to copyright protection as an "architectural work"under sec. 102 of the copyright act, 17 U.S.C. As amendedJanuary 2003. The protection includes, without limitation,the overall form, arrangement and composition of spaces,and elements of the design. Under such protection,unauthorized use of these drawings and specifications mayresult in cessation of construction, building seizure, and / ormonetary liability.16435 North Scottsdale Rd. Suite 195Scottsdale, Arizona 85254T+1 480 998 4200 F+1 480 998 7223www. .comAAD:FITCH, Inc.STORE EVOLUTION TEAM - STORE 2NORTH PRESTON & FRONTIER PKWYPROSPER, TX 75078DATE:SHEET:2019-02-05SCALE:DRAWN BY:PROJECT NUMBER:320108463-AS NOTEDVICTORY AT FRONTIER,BLOCK A, LOT 2.TOWN PROJECT NUMBERPREPARATION DATED18-0127/ D19-0063WEST ELEVATION - REAR3/32" : 1'-0"4SOUTH ELEVATION - SIDE3/32" : 1'-0"AEE-2NOTE:·THIS FACADE PLAN IS FOR CONCEPTUAL PURPOSES ONLY. ALLBUILDING PLANS REQUIRE REVIEW AND APPROVAL FROM THEBUILDING INSPECTIONS DEPARTMENT.·ALL MECHANICAL EQUIPMENT SHALL BE SCREENED FROM PUBLICVIEW. ROOFTOP MOUNTED EQUIPMENT SHALL BE SCREED BY APARAPET WALL OR SCREENING WALL. SCREENING WALLS SHALL BETHE SPECIFICATIONS OF THE ZONING ORDINANCE.·WHEN PERMITTED, EXPOSED UTILITY BOXES AND CONDUITS SHALLBE PAINTED TO MATCH THE BUILDING.·ALL SIGNAGE AREAS AND LOCATIONS ARE SUBJECT TO APPROVALBY THE BUILDING INSPECTIONS DEPARTMENT.·WINDOWS SHALL HAVE A MAXIMUM EXTERIOR VISIBLE REFLECTIVITYOF TEN (10) PERCENT.·ANY DEVIATION FROM THE APPROVED FACADE PLAN WILL REQUIRERE-APPROVAL BY THE TOWN OF PROSPER. +0'-0"FIN. FLR+19'-0"T.O. FASCIA+27''-0"T.O. ROOF+16'-0"B.O. FASCIADIMENSIONAL FASCIA BANDALPOLIC ACM PANELS IN BSM BLACKEYEBROW LIGHTING AT TOP OFCANOPY FASCIAENGINEERED STONEBASEEXCSM-1CORRUGATED PITCHED METAL ROOFPAINTED TO MATCH ALPOLIC ACMPANELS IN BSM BLACK16'-0"36'-0"152'-0"ENGINEERED STONEBASEEXCSM-1+0'-0"FIN. FLR+19'-0"T.O. FASCIA+27''-0"T.O. ROOF+16'-0"B.O. FASCIADIMENSIONAL FASCIA BANDALPOLIC ACM PANELS IN BSM BLACKCORRUGATED PITCHED METAL ROOFPAINTED TO MATCH ALPOLIC ACMPANELS IN BSM BLACKEYEBROW LIGHTING AT TOP OFCANOPY FASCIA33'-0"10'-0"8'-6"EQ.EQ.EQ.+0'-0"FIN. FLR+19'-0"T.O. FASCIA+27''-0"T.O. ROOF+16'-0"B.O. FASCIADIMENSIONAL FASCIA BANDALPOLIC ACM PANELS IN BSM BLACKEYEBROW LIGHTING AT TOP OFCANOPY FASCIAENGINEERED STONEBASEEXCSM-1CORRUGATED PITCHED METAL ROOFPAINTED TO MATCH ALPOLIC ACMPANELS IN BSM BLACK16'-0"36'-0"COPYRIGHT NOTICE:These drawings and specifications are copyrighted andsubject to copyright protection as an "architectural work"under sec. 102 of the copyright act, 17 U.S.C. As amendedJanuary 2003. The protection includes, without limitation,the overall form, arrangement and composition of spaces,and elements of the design. Under such protection,unauthorized use of these drawings and specifications mayresult in cessation of construction, building seizure, and / ormonetary liability.16435 North Scottsdale Rd. Suite 195Scottsdale, Arizona 85254T+1 480 998 4200 F+1 480 998 7223www. .comAAD:FITCH, Inc.STORE EVOLUTION TEAM - STORE 2NORTH PRESTON & FRONTIER PKWYPROSPER, TX 75078DATE:SHEET:2019-02-05SCALE:DRAWN BY:PROJECT NUMBER:320108463-AS NOTEDVICTORY AT FRONTIER,BLOCK A, LOT 2.TOWN PROJECT NUMBERPREPARATION DATED18-0127/ D19-0061FUEL CANOPY- SIDE3/32" : 1'-0"2FUEL CANOPY- FRONT3/32" : 1'-0"AEE-43FUEL CANOPY- PERSPECTIVENTS COPYRIGHT NOTICE:These drawings and specifications are copyrighted andsubject to copyright protection as an "architectural work"under sec. 102 of the copyright act, 17 U.S.C. As amendedJanuary 2003. The protection includes, without limitation,the overall form, arrangement and composition of spaces,and elements of the design. Under such protection,unauthorized use of these drawings and specifications mayresult in cessation of construction, building seizure, and / ormonetary liability.16435 North Scottsdale Rd. Suite 195Scottsdale, Arizona 85254T+1 480 998 4200 F+1 480 998 7223www. .comAAD:FITCH, Inc.STORE EVOLUTION TEAM - STORE 2NORTH PRESTON & FRONTIER PKWYPROSPER, TX 75078DATE:SHEET:2019-02-05SCALE:DRAWN BY:PROJECT NUMBER:320108463-AS NOTEDVICTORY AT FRONTIER,BLOCK A, LOT 2.TOWN PROJECT NUMBERPREPARATION DATED18-0127/ D19-006AEE-51EXTERIOR RENDERED VIEWNTS View GARCO, LLC | Kendall, Florida Samples From the 100° heat to hurricane force winds and rain, buildings in south Florida are subject to extreme and often punishing weather. For property owners, it’s essential to have exterior facades that can endure the challenging conditions—and look good doing it. The right exterior solutions can directly influence building cost and property value. The leadership of GARCO, LLC, a custom homebuilder near Miami, are keenly aware of the need for exterior building materials that are substantial, strong, and stylish. When the GARCO company headquarters was relocated to a new facility in Kendall, Florida, the team behind the project specified Crossville’s gauged porcelain tile panels to skin the exterior of the new location. More than just a “pretty facade”, the Crossville porcelain panels serve as a formidable, non-load bearing layer that serves to protect the building from the effects of weather. With its ability to skin a variety of surfaces, Crossville’s gauged porcelain tile panels offer many unique benefits that made them ideal for this highly visible corporate headquarters. The design team opted to incorporate the aesthetically appealing I Naturali collection to cover the exterior surfaces and columns at the building’s entrance. The I Naturali panels offer a classic, artisanal natural stone look and come in the large size of 1m x 3m. These generous outer dimensions provide efficiency in installation, fewer grout joints, and a more sleek and uninterrupted look. Tile contractor Ivan “Chino” Herrera, owner of The Miami Floors, is a qualified installer of gauged porcelain tile panels. He attended workshops sponsored by Crossville to be trained in the proper installation methodology and is now very experienced in working with the material through a variety of other projects. For the GARCO installation, Herrera and his team had the porcelain tile panels delivered to the jobsite and hoisted to the roof where they were cut down to 78” x 27” panels for the large areas and 27” x 27” for the columns. The panels were direct bonded to a cement substrate using Laticrete Hydro Ban waterproofing and Laticrete 254 Platinum Thin-set mortar. Joints were filled with Laticrete Latasil Sealant. The result of this skillful effort is a durable facade that offers a nearly seamless natural stone style that will sustain beautifully regardless of the south Florida weather. It’s fitting that these innovative Crossville gauged porcelain tile panels are the Crossville Porcelain Tile Panels Complete Building's Exterior Facade https://crossvilleinc.com/inspiration-gallery/garco-south-florida/#crossvil... 1 of 2 11/30/2018, 5:22 PM exterior surfacing solution of choice for GARCO’s Kendall headquarters. The company, focused on showcasing the latest in homebuilding options, is now in a stunning facility that greets its guests with the latest advancement for exterior cladding. Distributor: D&B Tile Distributors Property Owner: GARCO, LLC Tile Contractor: The Miami Floor, Ivan Herrera – owner Photography: G. Richard Booth Crossville Porcelain Tile Panels Complete Building's Exterior Facade https://crossvilleinc.com/inspiration-gallery/garco-south-florida/#crossvil... 2 of 2 11/30/2018, 5:22 PM Built in the late 1950s, Bhojwani Tower was designed by Albert Anis, known for his Art Deco architecture throughout Miami. Originally a bank, the Bhojwani, located on the corner of one of Miami Beach’s busiest pedestrian intersections, operates as a mixed-use building with residential and retail areas. When beginning the renovation process, Kobi Karp Architecture and Interior Design not only had to consider updating the building’s exterior to stringent building codes but also meeting the requirements of the Miami Beach Historic Preservation Board. Due to hurricanes, South Florida’s coastal areas fall into the High Velocity Hurricane Zone. Miami-Dade identified that it isn’t wind and rain that causes the most damage in strong storms; it’s exterior building pieces that come loose and become projectiles during extreme conditions. Thus, the International Building Code does not allow anything larger than 3 square feet to be attached to the outside of a building because the adhesives used would cure before the cladding pieces are properly placed —especially in the area’s warm climate. This would make cladding more prone to fly off during storms. To meet all code and preservation requirements, the Kobi Karp design team specified Crossville’s I Naturali collection of gauged porcelain tile panels to cover the exterior walls of the Bhojwani Tower. The team also advised Miami-Dade County officials that the Crossville material would meet stringent building codes and come in on budget if mounted with HyCOMB USA’s innovative cladding system. The HyCOMB USA team worked with D&B Tile Distributors to deliver the solution for installation of Crossville’s gauged porcelain tile panels for this project. Daniel Slain of HyCOMB USA explains that the company’s system works with Crossville’s surfacing solution because of the unique backing configuration and proven performance during testing for extreme conditions. In the testing, a standard piece of 2″x4″ lumber is shot out of an air cannon at a rate of 50 feet per second. That’s over 34 miles per hour. This exercise shows simulated impact from airborne objects in hurricane situations. “We have a honeycomb backer that is .75” thick. We bond the gauged porcelain tile panels to our core. To comply with the code (for the High Velocity Hurricane Zone), HyCOMB panels were tested by shooting a 2″x4″ at 50 fps at our panels while sustaining minimal damage, but remained intact,” explains Slain. Crossville’s panels are 1M x 3M and relatively simple to work with for experienced installers who have received training with the material. The bonding of the tile panels to the HyCOMB USA core offers distinct efficiencies unparalleled by other surfacing options. Slain shares,”“To direct bond, it would require more time because each row would have to set for a day. Our panels are independent of each other and held in place by mechanical fasteners. They do not rest on the layer below. On normal size stone panels we would need a five-man crew. With the Crossville porcelain tile panels, we use three people and produce twice the square footage each day.” Another major advantage of using the Crossville tile panels is the weight compared to Crossville Porcelain Tile Panels Complete Building's Exterior Facade https://crossvilleinc.com/inspiration-gallery/bhojwani-tower-miami/ 1 of 2 11/30/2018, 5:24 PM other cladding options. These panels are light enough in weight to be handled by fewer workers. This is important to note for the Bhojwani project because of its location on a busy street corner in the heart of the tourist district. If the architects had specified natural stone, the project team would have faced more time-consuming challenges and safety issues. With the porcelain panels, the three-man crew was able to lift the tiles through the scaffolding and put in place using HyCOMB’s fastening system—reducing both time and risk factors for the project during installation. Beyond the benefits of installation efficiencies, the tile panels’ classic, timeless look answers aesthetic demands and are actually more consistent in appearance than other materials such as natural stone. The panels not only offer a beautiful appearance for the building, but they will also be able to withstand the harsh South Florida elements. They’re innately resistant to UV rays and are highly scratch-proof and resistant to deep abrasion. Also, the panels are eco-friendly, as the body of the tiles is comprised of natural raw materials, and the tile does not release toxins into the environment. Right style, right performance, right for the environment—Crossville’s porcelain tile panels are ideal for Miami Beach’s preservation standards and the seasonless appeal of this iconic destination. Architect: Kobi Karp Architecture and Interior Design Tile Installer: Carolina Correa with Stoneworks, USA Tile Distributor: D&B Tile Distributors Mechanical Fastening System: HyCOMB USA Photography: Dick Booth, Boca Publishing Crossville Porcelain Tile Panels Complete Building's Exterior Facade https://crossvilleinc.com/inspiration-gallery/bhojwani-tower-miami/ 2 of 2 11/30/2018, 5:24 PM Crossville, Inc. • P.O. Box 1168, Crossville, TN 38557 • Phone: 931.484.2110 • Fax: 931.456.2956 • E-Mail: Crossc@CrossvilleInc.com • CrossvilleInc.com Natural Inspirations – Fokos Fokos – 3+ and 5.6mm Gauged Porcelain Tile Panels Sand, earth, salt and rock come together in a palette inspired by Grecian landscape. Where earth meets man and nature converges with design you find Fokos. Rena - L3917 - 5.6 (Floors & Walls) - Stocking L4903 - 3+ (Walls) - Special Order Roccia - L3916 - 5.6 (Floors & Walls) - Stocking L4482 - 3+ (Walls) - Special Order Piombo - L4338 - 5.6 (Floors & Walls) - Stocking L4879 - 3+ (Walls) - Special Order Terra - L3915 - 5.6 (Floors & Walls) - Stocking L4496 - 3+ (Walls) - Special Order Sale - L3914 - 5.6 (Floors & Walls) - Stocking L4489 - 3+ (Walls) - Special Order Note! These samples depict base color and sheen. Please refer to our website for a more accurate depiction of veining and pattern. *See chart on the next page for further information Crossville, Inc. • P.O. Box 1168, Crossville, TN 38557 • Phone: 931.484.2110 • Fax: 931.456.2956 • E-Mail: Crossc@CrossvilleInc.com • CrossvilleInc.com Natural Inspirations – Fokos Specifications Product Codes Series and Color Item Codes Special Order Sizes** 3+ 1M3M 3+ 1M1M**5.6 1M3M**5.6 1M1M 3+5.6 Fokos Piombo L4879.1M3M †L4338.1M3M †x Fokos Rena L4903.1M3M †L3917.1M3M †x Fokos Roccia L4482.1M3M †L3916.1M3M †x Fokos Sale L4489.1M3M †L3914.1M3M †x Fokos Terra L4496.1M3M †L3915.1M3M †x † Please Contact Customer Service for lead times and availability. ** Special Order Items are only sold in full crate quanities. Sand, earth, salt and rock come together in a palette inspired by Grecian landscape. Where earth meets man and nature converges with design you find Fokos. • Available in 3+ for wall use and 5.6 for floor and wall use • Unparalleled testing and training ensures high performance • Suitable for indoor surfaces Product Features & Benefits Laminam 5.6 Fokos_Rena Laminam 5.6mm Floor - Fokos_Piombo Backsplash - Crossville Yin + Yang Koi Pond Hex Laminam 1 meter x 1 meter sheets* LAMINAM 3+ LAMINAM 5.6 Piece 10.76 sq. ft./piece 10.76 sq. ft./piece Carton 3 pc./carton 2 pc./carton Sq. ft./carton 32.28 sq. ft./carton 21.52 sq. ft./carton Sq. ft./pallet 1.097.52 sq. ft./pallet 538.0 sq. ft./pallet Lbs./piece 18.07 lbs./piece 31.27 lbs./piece Lbs./pallet 1,843.14 lbs./pallet 1,563.50 lbs./pallet Cartons/pallet 34 cartons/pallet 25 cartons/pallet Laminam 1 meter x 3 meter sheets* LAMINAM 3+LAMINAM 5.6 Piece 32.29 sq. ft./piece 32.29 sq. ft./piece Crate 20 pc./crate 13 pc./crate Sq. ft./crate 645.80 sq. ft./crate 419.77 sq. ft./crate Lbs./piece 51.66 lbs./piece 93.96 lbs./piece Lbs./crate 1,285 lbs./crate (includes crate weight) 1,422 lbs./crate (includes crate weight) Sq. ft. minimum order 32.29 sq. ft.32.29 sq. ft. * Laminam arrives in oversize crates. These crates require proper receiving and handling equipment. Note: Non-full crate orders of 5.6mm Laminam or mixed orders of 3+ and 5.6 mm will arrive on vertical A-frame type crates. These A-frames require the same specialized handling equipment.Please refer to the Laminam technical guide online for receiving and handling information at LaminambyCrossville.com. Crossville, Inc. • P.O. Box 1168, Crossville, TN 38557 • Phone: 931.484.2110 • Fax: 931.456.2956 • E-Mail: Crossc@CrossvilleInc.com • CrossvilleInc.com Foundations – Blend Grigio - L1367 - 3+ (Walls) - Stocking L 3521 - 5.6* (Floors & Walls ) - Stocking Nero - L1510 - 3+ (Walls) - Stocking L4401 - 5.6* (Floors & Walls ) - Stocking Blend – 3+ and 5.6mm Gauged Porcelain Tile Panels Avorio - L2048 - 3+ (Walls) - Stocking L4538 - 5.6* (Floors & Walls ) - Stocking Noce - L2049 - 3+ (Walls) - Stocking L4743 - 5.6* (Floors & Walls ) - Stocking Note! These samples depict base color and sheen. Please refer to our website for a more accurate depiction of veining and pattern. *See chart on the next page for further information Flexible, versatile and inspired by cement, with a special speckled visual effect. Blend reveals remarkably broad-ranging application possibilities, making it ideal for the world of interior design Crossville, Inc. • P.O. Box 1168, Crossville, TN 38557 • Phone: 931.484.2110 • Fax: 931.456.2956 • E-Mail: Crossc@CrossvilleInc.com • CrossvilleInc.com • Available in 3+ for wall use and 5.6 for floor and wall use • Unparalleled testing and training ensures high performance • Suitable for indoor surfaces Laminam 1 meter x 1 meter sheets* LAMINAM 3+ LAMINAM 5.6 Piece 10.76 sq. ft./piece 10.76 sq. ft./piece Carton 3 pc./carton 2 pc./carton Sq. ft./carton 32.28 sq. ft./carton 21.52 sq. ft./carton Sq. ft./pallet 1.097.52 sq. ft./pallet 538.0 sq. ft./pallet Lbs./piece 18.07 lbs./piece 31.27 lbs./piece Lbs./pallet 1,843.14 lbs./pallet 1,563.50 lbs./pallet Cartons/pallet 34 cartons/pallet 25 cartons/pallet Laminam 1 meter x 3 meter sheets* LAMINAM 3+LAMINAM 5.6 Piece 32.29 sq. ft./piece 32.29 sq. ft./piece Crate 20 pc./crate 13 pc./crate Sq. ft./crate 645.80 sq. ft./crate 419.77 sq. ft./crate Lbs./piece 51.66 lbs./piece 93.96 lbs./piece Lbs./crate 1,285 lbs./crate (includes crate weight) 1,422 lbs./crate (includes crate weight) Sq. ft. minimum order 32.29 sq. ft.32.29 sq. ft. * Laminam arrives in oversize crates. These crates require proper receiving and handling equipment. Note: Non-full crate orders of 5.6mm Laminam or mixed orders of 3+ and 5.6 mm will arrive on vertical A-frame type crates. These A-frames require the same specialized handling equipment.Please refer to the Laminam technical guide online for receiving and handling information at LaminambyCrossville.com. Foundations – Blend Specifications Product Codes Product Features Series and Color Item Codes Special Order Sizes** 3+ 1M3M 3+ 1M1M**5.6 1M3M 5.6 1M1M**3+5.6 Blend Avorio L2048.1M3M †L4538.1M3M †x Blend Grigio L1367.1M3M †L3521.1M3M †x Blend Nero L1510.1M3M †L4401.1M3M †x Blend Noce L2049.1M3M †L4743.1M3M †x † Please Contact Customer Service for lead times and availability. ** Special Order Items are only sold in full crate quanities. Laminam 3+ Blend_ Avorio Collection_Notte Laminam 3+ Blend_ Nero Architects: Kelly Architect (George Kelly and Jen Smith) Crossville, Inc. • P.O. Box 1168, Crossville, TN 38557 • Phone: 931.484.2110 • Fax: 931.456.2956 • E-Mail: Crossc@CrossvilleInc.com • CrossvilleInc.com FS-LAM-BLEND-17 Distinctive Values MAIN FEATURES Dimensions 1000x3000mm Perfectly Flat 3+: 52 lbs / pc 5.6: 94 lbs / pc CHEMICAL RESISTANCE Laminam resists organic and inorganic solvents, disinfectants and detergents. It can be easily cleaned without affecting its surface characteristics; the only product that can attack the slabs is hydrofluoric acid. WEAR RESISTANCE Laminam is highly scratch proof and resistant to deep abrasion. The properties of the slabs remain unchanged even after intensive use and frequent cleaning. HIGH FLEXURAL STRENGTH Laminam has a high modulus of rupture. 3+ is 90 MOR and 5.6 is 50 MOR which are high values. Typical porcelain value is 35-37. FROST RESISTANCE Laminam’s average water absorption is 0.1% therefore it is frost resistant and suitable for any weather condition. FIRE RESISTANT Laminam does not contain organic material therefore it is resistant to fire and high temperatures. In the event of fire it does not release smoke or toxic substances. CHROMATIC PROPERTIES Laminam does not contain organic pigments and is resistant to UV rays. Even if subjected to severe climate changes, the colors remain stable. GRAFFITI Laminam is a graffiti resistant ceramic surface; it is easy to clean and even the strongest paints can be removed. SUSTAINABLE • The use of hybrid kilns that combine gas and electricity significantly reduces CO2 emissions in the atmosphere • Laminam has led the way to a photovoltaic system being installed on the roofs of its two Fiorano Modenese plants • Over a year, this photovoltaic system guarantees the production of around 1,050 GWh, thereby enabling the company to produce 10% of its energy requirements • In terms of CO2 reduction, Laminam's photovoltaic roof system eliminates the release of 525 tons of CO2 into the atmosphere annually • Member of the Green Building Council Italia, this Italian association of manu- facturing leaders strive to transform the building market towards environ- mental sustainability and to build livable communities. Partners of GBC Italia promote environmental, economic and social responsibility by innovating the way in which buildings are designed, built and used. Information listed here is subject to change. Please refer to LaminambyCrossville.com for the latest, most accurate information. Environmental Statement Laminam is a dynamic, flexible and rapidly growing company that makes recycling and sustainability its duty. The revolutionary slab produced by Laminam does not neglect environmental friendliness: natural raw materials, sustainable technology, entirely recyclable products are at the heart of the company’s green philosophy. Laminam is associated with the Green Building Council: created with natural materials, the slab does not release any substance into the environment and unbacked can be easily milled and recycled in other production cycles. Laminam slabs are produced adopting sustainable technol- ogy which respects the entire ecosystem and is designed to reduce processing waste to a minimum and to limit the use of resources. The use of hybrid kilns that combine gas and electricity significantly reduces CO2 emissions in the atmosphere. Thanks to its large format Laminam optimizes the transport, thus reducing the emission of particulate matter which is harmful for the environment. Moreover, Laminam has recently completed its own photovoltaic roof, a plant that today has already produced 1 GWh of energy and that in one year is expected to produce an estimated 1.387 GWh, therefore reducing the CO2 emission by 617 tons in the atmosphere and allowing Laminam to produce 15% of its energy requirements. About Laminam® by Crossville® Laminam, a brand which stands for innovative materials and unique technology, is the leader in large format porcelain panel production. Revolutionary technology concentrates three square meters into unbelievably thin por- celain: 3+ for interior walls and 5.6 for interior floors. Versatile and flexible, it is a genuine skin for contemporary architecture, and is ideal in a host of applications. Capable of anticipating lifestyle trends, accommodating the needs of design, and participating in the dialog of global architecture, Laminam and Crossville Inc. have joined together to bring Laminam® by Crossville® to the U.S. marketplace. Large format porcelain panels for interior walls and flooring– together, creativity is limitless. Applications Laminam® is suitable for many indoor applications: BUILDING SECTOR Floor and wall coverings, partition and storage walls, false ceilings, surface finishes and restoration, insulated panels and tunnels. INTERIOR DESIGN Surfaces of kitchen and bathroom tops, cupboards, tables, desks, doors and furnishings in general. SHIPBUILDING SECTOR The lightness and high technical properties of Laminam make it suitable for walls of cruise ships and sports crafts. COMPOSITE AND STRUCTURAL PANELS The slabs can be placed on top of each other or over other materials to create extremely light and particularly resistant composite and structural panels suitable in all those cases that require high resistance and reduced weight load on the surface. Technical Specifications LAMINAM 3+ and 5.6 mm Laminam porcelain obtained by wet grinding of clayish raw materials, granite and metamorphic feldspar-containing rocks and ceramic pigments. Com- pacted by a special shaping in compactor and sintering at 1200°C, with hybrid firing. Technical Info LAMINAM 3+ Laminam 3+ is made up of the basic slab with the structure reinforced with fiberglass matting applied on the back using special adhesive. Thickness: 3mm plus .5mm fiberglass mesh. Use of Laminam 3+ • Interior wall covering applied using adhesive LAMINAM 5.6mm • Interior floors below, and slab on interior floors above grade concrete and interior and exterior wall coverings. (See Laminam Technical Guide for more information). • Polished finishes require a penetrating sealer prior to grouting. Please Note: Due to DCOF value, these tile panels are not recommended for applications in wet areas or areas where standing water may occur. • Due to the grooved texture, when rail cutting Laminam Satori Beige, Crossville® recommends scoring face down. Foundations – Blend Crossville, Inc. • P.O. Box 1168, Crossville, TN 38557 • Phone: 931.484.2110 • Fax: 931.456.2956 • E-Mail: Crossc@CrossvilleInc.com • CrossvilleInc.com Natural Inspirations – Fokos Distinctive Values MAIN FEATURES Dimensions 1000x3000mm Perfectly Flat 3+: 52 lbs / pc 5.6: 94 lbs / pc CHEMICAL RESISTANCE Laminam resists organic and inorganic solvents, disinfectants and detergents. It can be easily cleaned without affecting its surface characteristics; the only product that can attack the slabs is hydrofluoric acid. WEAR RESISTANCE Laminam is highly scratch proof and resistant to deep abrasion. The properties of the slabs remain unchanged even after intensive use and frequent cleaning. HIGH FLEXURAL STRENGTH Laminam has a high modulus of rupture. 3+ is 90 MOR and 5.6 is 50 MOR which are high values. Typical porcelain value is 35-37. FROST RESISTANCE Laminam’s average water absorption is 0.1% therefore it is frost resistant and suitable for any weather condition. FIRE RESISTANT Laminam does not contain organic material therefore it is resistant to fire and high temperatures. In the event of fire it does not release smoke or toxic substances. CHROMATIC PROPERTIES Laminam does not contain organic pigments and is resistant to UV rays. Even if subjected to severe climate changes, the colors remain stable. GRAFFITI Laminam is a graffiti resistant ceramic surface; it is easy to clean and even the strongest paints can be removed. SUSTAINABLE • The use of hybrid kilns that combine gas and electricity significantly reduces CO2 emissions in the atmosphere • Laminam has led the way to a photovoltaic system being installed on the roofs of its two Fiorano Modenese plants • Over a year, this photovoltaic system guarantees the production of around 1,050 GWh, thereby enabling the company to produce 10% of its energy requirements • In terms of CO2 reduction, Laminam's photovoltaic roof system eliminates the release of 525 tons of CO2 into the atmosphere annually • Member of the Green Building Council Italia, this Italian association of manu- facturing leaders strive to transform the building market towards environ- mental sustainability and to build livable communities. Partners of GBC Italia promote environmental, economic and social responsibility by innovating the way in which buildings are designed, built and used. Information listed here is subject to change. Please refer to LaminambyCrossville.com for the latest, most accurate information. Environmental Statement Laminam is a dynamic, flexible and rapidly growing company that makes recycling and sustainability its duty. The revolutionary slab produced by Laminam does not neglect environmental friendliness: natural raw materials, sustainable technology, entirely recyclable products are at the heart of the company’s green philosophy. Laminam is associated with the Green Building Council: created with natural materials, the slab does not release any substance into the environment and unbacked can be easily milled and recycled in other production cycles. Laminam slabs are produced adopting sustainable technol- ogy which respects the entire ecosystem and is designed to reduce processing waste to a minimum and to limit the use of resources. The use of hybrid kilns that combine gas and electricity significantly reduces CO2 emissions in the atmosphere. Thanks to its large format Laminam optimizes the transport, thus reducing the emission of particulate matter which is harmful for the environment. Moreover, Laminam has recently completed its own photovoltaic roof, a plant that today has already produced 1 GWh of energy and that in one year is expected to produce an estimated 1.387 GWh, therefore reducing the CO2 emission by 617 tons in the atmosphere and allowing Laminam to produce 15% of its energy requirements. About Laminam® by Crossville® Laminam, a brand which stands for innovative materials and unique technology, is the leader in large format porcelain panel production. Revolutionary technology concentrates three square meters into unbelievably thin por- celain: 3+ for interior walls and 5.6 for interior floors. Versatile and flexible, it is a genuine skin for contemporary architecture, and is ideal in a host of applications. Capable of anticipating lifestyle trends, accommodating the needs of design, and participating in the dialog of global architecture, Laminam and Crossville Inc. have joined together to bring Laminam® by Crossville® to the U.S. marketplace. Large format porcelain panels for interior walls and flooring– together, creativity is limitless. Applications Laminam® is suitable for many indoor applications: BUILDING SECTOR Floor and wall coverings, partition and storage walls, false ceilings, surface finishes and restoration, insulated panels and tunnels. INTERIOR DESIGN Surfaces of kitchen and bathroom tops, cupboards, tables, desks, doors and furnishings in general. SHIPBUILDING SECTOR The lightness and high technical properties of Laminam make it suitable for walls of cruise ships and sports crafts. COMPOSITE AND STRUCTURAL PANELS The slabs can be placed on top of each other or over other materials to create extremely light and particularly resistant composite and structural panels suitable in all those cases that require high resistance and reduced weight load on the surface. Technical Specifications LAMINAM 3+ and 5.6 mm Laminam porcelain obtained by wet grinding of clayish raw materials, granite and metamorphic feldspar-containing rocks and ceramic pigments. Com- pacted by a special shaping in compactor and sintering at 1200°C, with hybrid firing. Technical Info LAMINAM 3+ Laminam 3+ is made up of the basic slab with the structure reinforced with fiberglass matting applied on the back using special adhesive. Thickness: 3mm plus .5mm fiberglass mesh. Use of Laminam 3+ • Interior wall covering applied using adhesive LAMINAM 5.6mm • Interior floors below, and slab on interior floors above grade concrete and interior and exterior wall coverings. (See Laminam Technical Guide for more information). • Polished finishes require a penetrating sealer prior to grouting. Please Note: Due to DCOF value, these tile panels are not recommended for applications in wet areas or areas where standing water may occur. • Due to the grooved texture, when rail cutting Laminam Satori Beige, Crossville® recommends scoring face down. FS-LAM-FOKOS-17 CROSSVILLE INCORPORATED/USA Limited Product Warranty LAMINAM® 3+ Wall and 5.6 Floor/Wall This warranty document also serves as a Certificate of Compliance. Crossville Incorporated guarantees that its LAMINAM 3+ Wall and 5.6 Floor/Wall products will meet or exceed the performance specifications outlined in ANSI 137.3 - 2017. Residential Lifetime Quality Warranty Should any Laminam 3+ Wall and 5.6 Floor/Wall product installed in a residential setting fail due to a manufacturing defect, Crossville Inc. replace the defective product pieces as it deems fit (installation not included). This Crossville Inc.’s Limited Lifetime Warranty covers your purchase of Crossville Inc. Laminam 3+ Wall and 5.6 Floor/Wall products for as long as you own your home. This warranty is non-transferable. Commercial Warranty In the event of latent defects caused by improper manufacture, the company will replace any defective units FOB plant (installation not included), provided the company is notified within one year of installation or within 18 months of shipment of product, whichever occurs first. Regarding both Residential and Commercial Limited Warranty’s, specific installation details, structural design and environmental conditions are beyond the control of the company. Crossville Inc. cannot accept responsibility for the performance of its products where improper installation, design or environmental conditions exist. DISCLAIMER Laminam 3+ Wall and 5.6 Floor/Wall, by the nature of the product, is a material that is subject to variation in veining and/or color as well as technical specifications. This is due to the variability of the natural raw ingredients and the production process itself. Any misuse of the product by the customer including physical or chemical abuse, or negligence is not covered under warranty. Installation defects or deficiencies are not covered by this warranty. Any defect visual or otherwise that is apparent prior to installation is not covered by this warranty. Samples and merchandising are for general reference only. In no event shall Crossville Inc.’s liability on any claim made by anyone exceed the purchase price paid for the product by said customer in respect to the Crossville Inc. materials on which damages are being claimed. You can find more information about our many tile products, along with other Product Performance Data and installation specifications at www.crossvilleinc.com or call (931)-484-2110 Technical Services Crossville Incorporated 7-17 Crossville's Technical Manual ⁄ Guidelines Laminam 3+ and 5.6 Your exclusive source for Laminam in the United States LIT-LAMII-16 May 2016 Information listed here is subject to change. Please refer to LaminambyCrossville.com for the latest, most accurate information. Installation Manual 3 04 1 THE PRODUCT 1.1 Laminam 3+ 1.2 Laminam 5.6 05 2 PACKING SPECIFICATIONS 2.1 Laminam 1 Meter x 1 Meter 2.2 Laminam 1 Meter x 3 Meter 06 3 MATERIAL HANDLING 3.1 Fork Lift Requirements 07 3.2 Ideal Handling Equipment 3.3 Shipping and Unloading Requirements 3.4 Manual Handling and Storage 08 3.5 Euro-Grip/Euro-Slide Frame/Transporter 4 INSTALLATION 4.1 Current Applications Laminam 3+ 4.2 Current Applications Laminam 5.6 09 4.3 Countertops 4.4 Suitable Substrates - Walls 4.5 Suitable Substrates - Floors 4.6 Substrate Requirements 4.7 Movement Joints 10 4.8 Install with Qualified Labor 5 INSTALLATION PROCESS 5.1 Installation Recommendations 10 5.2 Portable Work Station 11 5.3 Recommended Equipment 11-12 5.4 Use of Rail Cutters 12 5.5 Cutting and Drilling 5.6 Dry Cutting Electrical Boxes 5.7 Mortar Application 12-14 5.8 Application to the Substrate 15 5.9 Grouting 5.10 Edge Treatments and Profiles 16 5.11 Critical Review Points 6 CARE AND MAINTENANCE 6.1 Initial Care and Maintenance 7 TECHNICAL PERFORMANCE 7.1 Product Specifications 17 8 MORTAR AND GROUT SELECTION GUIDE 8.1 Manufacturer’s Product Information 18 9 EXTERIOR DIRECT BOND GUIDELINES 9.1 Code Compliance and Approval 9.2 Installation Methods 9.3 Selection of Setting Material Company 19 9.4 Laminam Tech Guide 9.5 Qualified Labor 20 Contact Information These porcelain tile panels are produced with an innovative tile technology. By pressing without the traditional die-mold commonly used throughout the tile industry, then firing with highly controlled kilns at a temperature of approximately 2200 degrees F, this breakthrough process successfully eliminates tension within the tile panel creating a uniformly large flat piece that can be cut or trimmed with precise accuracy. The Laminam 3+ porcelain tile panels also have a fiberglass mesh permanently adhered to the back for additional strength and flexibility. All installation systems to utilize applicable TCNA Handbook detail and additionally the installation guidelines detailed in this manual. • Interior walls and countertops • Exterior Walls per exterior direct bond guidelines in section 9 • Cut to size is available with additional lead time and cost. Check with Crossville customer service for details (931-484-2110) These porcelain tile panels are produced with an innovative tile technology. By pressing without the traditional die-mold commonly used throughout the tile industry, then firing with highly controlled kilns at a temperature of approximately 2200 degrees F, this breakthrough process successfully eliminates tension within the tile panel creating a uniformly large flat piece that can be cut or trimmed with precise accuracy. All installation systems to utilize applicable TCNA Handbook detail and additionally the installation guidelines detailed in this manual. • Interior Floors slab on grade, below grade, or above grade concrete and over well-bonded and properly prepared tile, on, below, or above grade • Laminam 5.6 porcelain tile panels over substrates supported by wood framing shall utilize TCNA Handbook details F141-15 STONE or F250-15 STONE. Consult the installation materials manufacturer you are using to confirm acceptability of this recommendation. • Interior walls and countertops • Exterior Walls per exterior direct bond guidelines in section 9 • Interior Stairs constructed per TCNA S151 - consideration should be given to appropriate DCOF and wear/impact resistance. Pre-formed stair nosing profiles should be considered. • Cut to size is available with additional lead time and cost. Check with Crossville customer service for details (931-484-2110) ;/,796+<*; 3HTPUHT7VYJLSHPU;PSL7HULSZ4,;,9_4,;,9HUK4,;,9_4,;,9 3HTPUHT7VYJLSHPU;PSL7HULSZ4,;,9_4,;,9HUK4,;,9_4,;,9 4 7(*205.:7,*0-0*(;065: FIG. 1 LAM-CRATE = minimum 44” fork length required for side lift FIG. 2 LAM-CRATE = minimum 84” fork length required for end lift FIG. 3 A-FRAME Note: Non-full crate orders of 5.6mm Laminam or mixed orders of 3+ and 5.6 mm will arrive on vertical A-frame type crates (depends on quantities, timing, and thicknesses on the order - check with Crossville Customer Service for details 931-484-2110). Full crate orders transferred to A-frames will incur additional charges and lead times. LAMINAM 3+ Porcelain Tile Panels LAMINAM 5.6 Porcelain Tile Panels PIECE 10.76 sq. ft. / piece 10.76 sq. ft. / piece CARTON 3 pc. / carton 2 pc. / carton SQ. FT. / CARTON 32.28 sq. ft. / carton 21.52 sq. ft. / carton SQ. FT. / PALLET 807 sq. ft. / pallet 538.0 sq. ft. / pallet LBS / PIECE 18.07 lbs. / piece 31.27 lbs. / piece LBS / PALLET 1,843.14 lbs. / pallet 1,563.50 lbs. / pallet CARTONS /PALLET 25 cartons / pallet 25 cartons / pallet 3(405(44,;,9?4,;,9 3(405(44,;,9?4,;,9 LAMINAM 3+ Porcelain Tile Panels LAMINAM 5.6 Porcelain Tile Panels PIECE 32.29 sq. ft. / piece 32.29 sq. ft. / piece CRATE 20 pc. / crate 13 pc. / crate SQ. FT. / CRATE 645.80 sq. ft. / crate 419.77 sq. ft. / crate LBS / PIECE 54.25 lbs. / piece 93.81 lbs. / piece LBS / CRATE 1,285 lbs. / crate (includes crate weight)1,419.53 lbs. / pallet (includes crate weight) SQ. FT MINIMUM ORDER 32.29 sq. ft.32.29 sq. ft. Laminam Porcelain Tile Panels arrive in oversize crates. These crates require proper receiving and handling equipment. Laminam Porcelain Tile Panels arrive in oversize crates. These crates require proper receiving and handling equipment.   5 STANDARD FORK LIFT-SIDE Handling of the Lam-crate – recommend 44” forks to handle the crate from the side. Important to have 44” forks so they extend all the way across the crate to support the back runner. As shown in fig. 4. CROSS RUNNERS Shipments of Laminam crates will load with the narrow end of the crate facing out. Unloading will require a fork truck with a minimum of 84" forks and 5000 pound lift capacity. If you have a fork length shorter than 84" you will miss the cross-runner and cause damage, especially when tilting back. As shown in fig. 5 & 6. It is important to support the cross runners. You can see the cross-runners in fig. 5. 4(;,90(3/(5+305. -VYR3PM[9LX\PYLTLU[Z CR4=84” FIG. 4 – LAM-CRATE standard fork lift - side FIG. 5 – LAM-CRATE – CROSS RUNNERS view of crate with 84” forks underneath FIG. 6 – LAM-CRATE – CROSS RUNNERS Underside view with 84” forks 6 96" CRATE TRUCK / PALLET JACK A crate truck or pallet jack is recommended to move crates in your warehouse. These units have 96" forks to lift crates straight up without tilting. 96" extended fork pallet jacks are also available from U-Line (800-295-5510) or Vestil (800-348-0868). 4(;,90(3/(5+305. 0KLHS/HUKSPUN,X\PWTLU[ Container loads are stacked 8 crates high, weighing 10,000 pounds. If you have a direct container shipment, it requires different equipment. Please contact Crossville for logistical assistance with container orders. Crossville normally ships its crates a maximum of 3 crates high. Customers can handle these shipments with 5000 pound capacity fork lifts and 84" forks. :OPWWPUNHUK<USVHKPUN9LX\PYLTLU[Z FIG. 7 – CRATE TRUCK FORKS & PALLET JACK Handling Video - O[[W!IP[S`/HUKSPUN7VYJLSHPU;PSL7HULSZ Two installers should handle the tile panels, always keeping it perpendicular to the floor while protecting the corners from impact (fig. 8). Grip gloves are required when lifting and moving the tile panels to ensure positive hold and to protect hands against fiberglass backing and tile edges (3+ mm). Position the tile panels on the long side allowing them to lean against a supporting wall while keeping cardboard or wooden strips suitably spaced beneath them (fig. 9). • CAUTION - Crates come equipped with metal corner collars for stacking. To create awareness and avoid injury, paint, cover or remove these collars (fig. 10). 4HU\HS/HUKSPUNHUK:[VYHNL FIG. 8 FIG. 9 FIG. 10 7 To aid handling of 1meter x 3 meter (39.4" x 118.1") tile panels, especially those weakened by drilled holes or openings and to assist the wall/floor application, a suitable frame with suction cups can be used. The Euro-Grip/Euro-Slide can be purchased from European Tile Masters (www.europeantilemasters.com) (Euro-Grip fig. 11a). The Euro-Grip/Euro-Slide can be reconfigured for use with sizes smaller than full tile panels. Always check the adhesion of the suction cups on the tile panels prior to lifting. For efficient moving of up to 8-16 tile panels, the Euro Transporter is available from European Tile Masters. (fig. 11b) 4(;,90(3/(5+305. ,\YVWLHU;PSL4HZ[LYZ,\YV.YPW,\YV:SPKL-YHTL 05:;(33(;065 *\YYLU[(WWSPJH[PVUZ3HTPUHT • Interior Walls • Exterior Walls (see section 9) • Countertops • Laminam 3+ Porcelain Tile Panels are NOT rated for floor applications • Laminam 3+ can be used on walls in a concave or convex direction as long as the radius (r) of the curve equals or exceeds 5 meters (16.4 feet) - applies only to 3+ in full meter length (10 feet) (fig. 12) • Tile over tile (walls) - consult setting material manufacturer for appropriate primer or other specific bonding requirements. Existing substrates must comply with section 4.6. FIG. 11a *\YYLU[(WWSPJH[PVUZ3HTPUHT • Interior Walls • Exterior Walls (see section 9) • Countertops • Interior Floors slab on grade, below grade, or above grade concrete-minimum cure 90 days. • Interior Floors tile over tile on slab on grade, below grade, or above grade concrete. • Deflection requirements for above grade installations to be per TCNA Handbook: “Floor systems over which tile will be installed shall be in compliance with the IRC for residential applications, the IBC for commercial applications, or applicable building codes. Maximum allowable deflection under live load not to exceed L/360”. • Interior Stairs constructed per TCNA S151 - consideration should be given to appropriate DCOF and wear/impact resistance. Pre-formed stair nosing profiles should be considered. • Acceptable substrates to be in accordance with Tile Council of North America (TCNA) and ANSI guidelines. • For tile over tile applications refer to specific setting material manufacturer recommendations for additional surface preparation including primers or other specific bonding requirements. • Laminam 5.6 porcelain tile panels over substrates supported by wood framing shall utilize TCNA Handbook details F141-15 STONE or F250-15 STONE. Consult the installation materials manufacturer you are using to confirm acceptability of this recommendation. • Laminam 5.6 porcelain tile panels should not be used on elevator floors due to excessive deflection of elevator substrates. • Laminam 5.6 porcelain tile panels should not be used in installations exposed to steel wheel traffic. • Laminam 5.6 porcelain tile panels when considered for heavy commercial (shopping malls, airports) applications will be considered on a case by case basis. Extra heavy commercial (food plants, dairies) applications are not recommended. • Laminam 5.6 porcelain tile panels have been tested and have been found acceptable for use with liquid trowel applied crack isolation membranes (see section 8 for specific products). Laminam 5.6 porcelain tile panels are NOT acceptable for use with other crack isolation, sound reduction, or uncoupling membranes until additional testing can be completed to verify the deformability and specific performance of individual membranes. Additional membranes will be added to section 8 when tested. Laminam 3+ on 16 foot (5 meters) minimum radius Concave or Convex Walls Applies only to 3+ in full meter length (10 feet) FIG. 12 r FIG. 11b 8 *V\U[LY[VWZ Extruded foam boards (1½ to 2 inches) from manufacturers such as Schluter and wedi are the preferred method of countertop installation for both the 3+ and the 5.6 mm Laminam. Their ease of installation, inherent water/vapor resistance, and high density composition eliminate many of the stresses that can be created with the traditional layered approach of plywood, backer board, and/or mortar beds. Crossville has found the following steps insure full supportive coverage and precise cutting of the combined assembly: Step 1, the installation of the extruded foam board to the base cabinets. Step 2, the Laminam 3+ or 5.6 should then be installed to the extruded foam board following the mortar application method detailed in Section 5.7 of this Technical Guide. Step 3, allow the assembly to cure 24 hours. Step 4, measure and template all cut outs in the countertop, cut from the top down using right angle grinder, diamond tipped hole saw and utility knife. When using these materials the respective manufacturer’s instructions and detailed installation guidelines should be followed. If using a traditional installation approach TCNA Handbook details C511, C512 or C513 should be followed. :\P[HISL:\IZ[YH[LZ¶>HSSZ0U[LYPVYHUK,_[LYPVY • Existing ceramic tile - see section 4.1 • Appropriate backer boards for tile as referenced and detailed by the TCNA Handbook for Ceramic Tile Installation • Properly prepared concrete and CMU walls • Gypsum board/dry wall (Interior dry areas only) • Mortar beds in accordance with ANSI A108.1B :\P[HISL:\IZ[YH[LZ¶-SVVYZ • Slab on grade, below grade, or above grade concrete in accordance with ANSI A108 and TCNA Handbook • Existing ceramic tile over slab on grade, below grade, or above grade concrete (well bonded and properly prepared) - see section 4.2 • Mortar beds over concrete in accordance with ANSI A108.1B • Laminam 5.6 porcelain tile panels over substrates supported by wood framing shall utilize TCNA Handbook details F141-15 STONE or F250-15 STONE. Consult the installation materials manufacturer you are using to confirm acceptability of this recommendation. • Laminam 5.6 can be used on walls, suitable substrates as designated in section 4.4 (interior and exterior) :\IZ[YH[L9LX\PYLTLU[Z¶>HSSZHUK-SVVYZ The installation contractor should examine substrates and advise General Contractor and Architect of existing conditions and surface contamination which will require correction before the work commences. In order to achieve accurately comparable labor quotes the specification must contain language indicating that the work is to be bid assuming the substrates are within the required tolerances. If the substrates are found not to be within those tolerances, language and/or pricing should be included in the installation contractor’s bid which qualifies which trade is to do the work needed to bring the substrate into required tolerances. (Include in CSI Div. 3 & 9). Substrates are to comply with deflection requirements called for by International Building Code (IBC), International Residential Code (IRC), or applicable local building code. Maximum substrate variation not to exceed 1/8" in 10' (3mm in 3m) and 1/16" in 24" (1.5mm in 60 cm) when measured from surface high points with a straight-edge, floors may require self-leveling underlayments or recessed slabs designed to accept a properly prepared mortar bed. 05:;(33(;065 4V]LTLU[1VPU[Z Refer to Tile Council of North America (TCNA) Detail EJ-171 for industry guidelines. Existing joints in substrate are to be carried through the porcelain tile panels. Movement joints are required where the tile panels meet restraining surfaces (e.g. perimeter walls, curbs, columns, corners, etc.) and at all changes in-plane in the tile work. Joints are to be clean and free of all contaminants and thin-set mortar. • The edges of the porcelain tile panels are not eased or beveled making them susceptible to damage from heavy rolling loads and impact. Full and flush movement and grout joints should be specified to minimize edge impact. • Minimum Shore A hardness rating of 35 or greater (per the TCNA Handbook) should be specified for all movement joints in traffic situations. Compressible joint fillers with less than a Shore A hardness of 35 should not be used. • All expansion joints specific to structural movement: material types and placement should be specified by architectural/engineering authority on the project. • For interior walls and floors an 1/8 inch movement joint installed every 20 feet will accommodate the needed movement of the tile layer on grade, below grade, or above grade* (all other requirements such as perimeter joints etc. in EJ-171 should followed). t *Assuming a class 25 sealant installed at 70°F,using a high temperature of 105°F and a low temperature of 40°F. t If specific movement joint requirements need to be calculated, use the anticipated temperature differentials, the appropriate class of sealant and a thermal expansion coefficient of 6.5 x 10-6 in/in/°C. • For exterior movement joints see section 9. 9 05:;(33(;065796*,:: For the most efficient and consistent cutting of the Laminam porcelain tile panels, Crossville recommends the Kera Cutter Rail System* by Sigma (fig. 13) or the Euro-Rail Cutter* by ETM. For usage guide on the Sigma Kera-Cut, see You Tube @ KERA-CUT presentation SIGMA. • For transport of the rail cutter, 6" to 8" pvc pipe w/fitted couplings for end closure (fig. 16) Crossville also recommends that portable work stations be assembled to insure proper support and fabrication of the tile panels. * Available from European Tile Masters (ETM) 954-917-3599 0UZ[HSSH[PVU9LJVTTLUKH[PVUZ Portable work stations consist of: • ¾" cabinet grade plywood cut into three, 4 foot square sections each with handles • 8 hinge plates with 4 chain mount cotter pins (fig. 14) • 2" flat aluminum strips screwed to each end of the center piece to reinforce & maintain table flatness • 4 heavy duty collapsible sawhorses (fig. 15) • Manufactured tables are available from various suppliers such as Raimondi (fig. 17) and ETM (fig. 18) 7VY[HISL>VYR:[H[PVUZ FIG. 13 FIG. 14 - Underside of the Assembled Work Station FIG. 16 FIG. 17 FIG. 15 FIG. 18 0UZ[HSS^P[O8\HSPÄLK3HIVY Crossville strongly recommends the use of trained professional contractors for the installation of these porcelain tile panels. The following programs are well established and a good source for quality installation companies: • ACT – Advance Certifications for Tile Installers • CTEF – Certified Tile Installer Program • TCAA – Trowel of Excellence • International Masonry Institute (IMI) • NTCA Five Star Contractor Program • Journeyman Tile Setter Apprenticeship Programs • And completion of Crossville sponsored training provided by Crossville Inc., a Crossville distributor, or other tile panel specific training authorized/approved by one of the above organizations • Find a list of Laminam Trained Contractors at crossvilleinc.com/solutions/laminam 05:;(33(;065 ETM Table Raimondi Table 10 05:;(33(;065796*,:: • Trowels - Euro Trowel, Raimondi Flow Ridge, or Superior Premium Notch for application to the floor or wall substrate and for application to back of the tile panel (fig. 19). The Flow Ridge and Premium Notch come in various notch heights, consult mortar manufacturer for appropriate notch size for application to the back of the tile panel and the substrate. • Pressure pliers for snapping the scored 3+ tile panels (fig. 20) • The Sigma Separator provides precise pressure when breaking the score line, particularly helpful with the thicker 5.6mm Laminam (fig. 21) • Raimondi coated beat in paddle (fig. 22) • Right angle grinder for L-cuts and electrical box cuts • 4" continuous rim diamond blade such as Alpha LM0438 • Sigma Kera-Edge for profiling and bullnosing Laminam 5.6 mm tile panels (fig. 23) • Diamond tip hole saw (fig. 24) • Lippage control straps and caps (fig. 25) • 60-400 grit diamond hand pads for edge smoothing & removal of excess fiberglass backing (fig. 26) • Grip gloves for handling the tile panels • Safety glasses • Laminam 3+ and 5.6 porcelain tile panels tiles require a two person crew minimum • Dust and Mist Respirator: The Laminam 3+ tile panels have a reinforcing fiberglass mesh, the residue can be irritating to skin, eyes and lungs 9LJVTTLUKLK,X\PWTLU[ Cutting and Drilling Video - O[[W!IP[S`*\[[PUN+YPSSPUN • First, clean the surface of the tile panel and the suction cups to ensure better suction to the face of the tile panel. • Use a rail cutter (fig. 27) to score the porcelain tile panel surface from end to end. Begin the scoring process with a small backward motion then proceed forward continuously with a firm downward pressure on the scoring handle. Note: A smaller diameter cutting wheel may be preferable for pebbled or textured finishes. • The rail will provide guidance and precision to the cut. Maintain a smooth, firm continuous movement. Do not interrupt or restart. • With the suction cups still attached, use the rail cutter as a handle to maneuver and reposition the scored tile panel to the edge of the work table. • Center the pressure pliers (Laminam 3+) or separator (Laminam 5.6) over the score line on one end of the tile panel. Gently apply pressure and the tile panel will break (fig. 20 & 21). Once the material starts to break down the score line, you may, depending on the width of the piece you are trying to remove, need to use hand pressure to work the break from the starting point to the other end of the tile. <ZLVM9HPS*\[[LYZO[[W!IP[S`*\[[PUN+YPSSPUN FIG. 24 FIG. 22 FIG. 21 FIG. 26 FIG. 23 FIG. 25 FIG. 27 FIG. 20 FIG. 19 11 Cutting and Drilling Video - O[[W!IP[S`*\[[PUN+YPSSPUN • It is recommended for electrical box cuts, before using a right angle grinder for the straight cuts (fig. 31), that four pilot holes should be drilled in each corner (fig. 29), these holes will help relieve surface tension and vibration where the straight cuts intersect. • Cutting must be from the tile panel face to the back, fully supporting the underside of the tile panel on a flat surface while cutting will help reduce stress and avoid cracking. • For smaller cuts and corner cuts the use of a simple high quality glass cutter such as the TOYO Pistol Grip Super Cutter (800-505-6311) and adjustable straight edge can be a useful alternative (fig. 30). In addition manual tile cutters and right angle grinders with a proper dry cut porcelain blade are also effective. +Y`*\[[PUN,SLJ[YPJHS)V_LZ Cutting and Drilling Video - O[[W!IP[S`*\[[PUN+YPSSPUN • Use diamond tipped hole saws in various diameters. • DO NOT USE HAMMER DRILLS. • Moderate pressure and speed are enough to minimize bit-walk and begin the hole. Water will cool the tile and provide lubrication to the drill bit. • For large radius or curved cuts a diamond grit jig saw blade by Bosch (T130DG) provides good results. *\[[PUNHUK+YPSSPUN • Installations are to comply with current revisions of ANSI A108.02, A108.1B and ANSI A108.5. Crossville has found through its training and testing that maximum edge to edge coverage is achieved through a series of the following best practices (and the embedding techniques 4VY[HY(WWSPJH[PVU 05:;(33(;065796*,:: FIG. 28 FIG. 29 FIG. 30 FIG. 31 <ZLVM9HPS*\[[LYZJVU[»K • For the 3+ material, fold the tile panel past 90 degrees and cut the fiberglass backing using a utility knife, then remove the severed piece. • Use a 60-400 grit diamond pad to ease the cut edge and remove the excess fiberglass backing - most effective and dust is minimized when used wet (fig. 26). listed in section 5.8): • Mix the chosen mortar to the wettest recommended consistency, providing maximum open time and greater adjustability when the tile panel is placed. Consult mortar manufacturer for appropriate mix ratios for use with porcelain tile panels. • Mist down the substrate with a garden sprayer or damp sponge (no pooling or standing water) to make sure the moisture in the thin-set is not lost too quickly and the open time is not reduced. • Be sure to scratch/key the mortar into the substrate and tile panel with the flat side of the trowel before combing. • Overspread the mortar by at least an inch wider than the tile panel you plan to embed. This is to ensure full support of mortar at the tile edges. • Do not allow mortar to “skin over”. • Use the appropriate trowel (fig. 19) to apply the mortar to the wall, floor, or countertop and to the back of the tile panel. • Mortar ridges on both the tile panel back and substrate must be parallel to each other, combing at right angles to the long side of the tile panel. Use the appropriate trowels and troweling technique (hold at least a constant 45° angle) and take care to keep the ridges straight and of consistent height. This is crucial to achieving maximum coverage. (fig 32) • On walls the use of a plastering hawk can greatly increase the efficiency of install. • On both floors and walls the resulting embedded mortar layer (using the double coat approach) will be approximately 5mm (slightly less than ¼ inch) 12 (WWSPJH[PVUVM[OL;PSL7HULS[V[OL:\IZ[YH[L Wall Installation Video - http://bit.ly/PorcelainTilePanelsWallInstallation • WALLS: Use the suction cupped frame to place the mortared tile panel onto the substrate and align prior to removal of the suction cupped frame. (fig. 34 & 35) • WALLS: Using a rubber grout float or Raimondi coated beat in paddle, tamp the centerline of the tile panel along its entire length prior to removing the suction cupped frame to provide initial adhesion of the tile panel to the wall. Once the suction cupped frame has been removed use a high-speed cordless orbital sander with pad or the Raimondi coated beat in paddle, work from the centerline of the tile panel outward 05:;(33(;065796*,:: FIG. 32 FIG. 33 FIG. 34 FIG. 35 FIG. 36 13 to the edges, this pressure will collapse the ridges, force air from behind, and maximize edge to edge coverage. A traditional 2 x 4 beat in block and rubber mallet should not be used as it places too much point load on the tile face and can cause fracturing/cracking of the tile panel. • WALLS: When installing multiple tile panels, lippage control straps and caps are required to minimize lippage between tile panel edges. The lippage control systems are designed only to fine tune lippage between tile edges, the main alignment of tile edges should be accomplished through proper mortar application and embedding techniques. After the first tile panel has been installed and the mortar has been spread for the second tile panel, place the straps uniformly along the edge of the first tile panel (two inches from the corner and approximately every 10 inches along the length), DO NOT apply the lippage control cap at this time. Once the second tile panel is in place and the same embedding procedure described above is accomplished insert the appropriate grout spacer and lippage control cap and then cinch down the lippage control caps tightly to bring adjoining tile edges into alignment. (fig. 36 & 39) • WALLS: Using a high-speed cordless sander with pad work along the edges of the tile panel and between each of the lippage control straps and caps, some additional tightening of the caps may be necessary. The combined use of a vibrating sander and cap tightening effectively increases mortar coverage along the vulnerable edge of the tile panel while at the same time minimizing edge lippage. (fig. 36) Floor Installation Video - http://bit.ly/PorcelainTilePanelFloorInstall • FLOORS: Use the suction cupped frame to place the mortared tile panel onto the substrate and align prior to removal of the suction cupped frame. (fig. 37 & 38) • FLOORS: Insuring maximum coverage between the tile panel and the substrate is critical to a successful installation. Crossville has found through its training and testing that the mortar application techniques described in section 5.7 along with the specific walking pattern described below is the most reliable and efficient way to eliminate voids in the mortar while maximizing edge to edge coverage (fig. 32 & 33). Care should be taken to remove any dried mortar or other debris from footwear. Start at the center point of the tile panel, and walk with small shuffling steps down the full length of the tile taking care to stay only in the center portion, then return to the center point and take small shuffling steps across the widths of the tile panel compressing the mortar ridges and forcing any entrapped air to escape along the tile panel’s edge. Continue this shuffling process until the entire tile panel has been compressed in the mortar. This process should take approximately 4 - 5 minutes for a full 1Mx3M tile panel. (WWSPJH[PVUVM[OL;PSL7HULS[V[OL:\IZ[YH[LJVU[»K (WWSPJH[PVUVM[OL;PSL7HULS[V[OL:\IZ[YH[LJVU[»K Coverage Video - http://bit.ly/CoverageDemo • FLOORS: When installing multiple tile panels, lippage control straps and caps are required to minimize lippage between tile panel edges. The lippage control systems are designed only to fine tune lippage between tile edges, the main alignment of tile edges should be accomplished through proper mortar application and embedding techniques. After the first tile panel has been installed and the mortar has been spread for the second tile panel, place the straps uniformly along the edge of the first tile panel (two inches from the corner and approximately every 10 inches along the length), DO NOT apply the lippage control caps at this time. Once the second tile panel is in place and the same embedding procedure described above is accomplished insert the appropriate grout spacers and lippage control caps and then cinch down the lippage control caps tightly to bring adjoining tile edges into alignment. (fig. 36 & 39) • FLOORS: Using a high-speed cordless sander with pad work along the edges of the tile panel and between each of the lippage control straps and caps, some additional tightening of the caps may be necessary. The combined use of a vibrating sander and cap tightening effectively increases mortar coverage along the vulnerable edge of the tile panel while at the same time minimizing edge lippage. (fig. 36) • FLOORS: Due to room configuration or job size it will be necessary to work ON freshly installed tile panels. When doing so, the use of a large piece of masonite or double walled heavy cardboard works well to protect the face of the tile from tool damage or ground in construction dirt, as well as disperse concentrated weight. Freshly set tiles should not be walked on after 90 minutes. This is to ensure that the bonding mortar is not compromised as it begins to cure. • WALLS & FLOORS: When cleaning excess mortar from the substrate make sure to leave the gaps open at the edge of the tile panel by cutting the mortar down and pulling away from the tile edges in a parallel direction to the ridges. This will facilitate further removal of air and collapse of the mortar ridges during the embedding procedures. • WALLS & FLOORS: Remove excess mortar from the tile panel’s surface and “clean-out” between the joints to the full depth (1/8” or 1/4”) of the tile panel while mortar is still fresh, this will insure an adequate amount of grout to fill the joint. Take extra time and be thorough on this step. • WALLS & FLOORS: Lippage control systems that allow for removal and replacement of the cap (after bringing the tiles into alignment) will allow for effective removal of excess mortar around the strap while the mortar is still fresh. After completing the removal of excess mortar, replace the caps on the straps and retighten to ensure complete alignment of the tile edges. This will reduce the possibility of damage 05:;(33(;065796*,::FIG. 37 to the tile the following day when clearing the grout joint of cured mortar. Video at: http://bit.ly/1hodjiW • WALLS & FLOORS: For ending a day’s work that will continue the next day, the most crucial step is to make sure the last tile panel is fully embedded and is checked with a straight edge for flatness/squareness across the surface before leaving it to cure. Consult the lippage control device manufacturer for their procedure of how to address ending one day’s work that will tie a cured tile panel into a new tile panel the next day. • Grout application times can vary from 24 hours to 72 hours; refer to specific guidelines from the grout manufacturer. FIG. 38 FIG. 39 14 WALLS • Crossville has found that there are many lippage control systems available. For timing and method/timing of removal refer to lippage control system manufacturer’s requirements. • 2mm to 3mm grout joint size is recommended based on wall flatness. • Use of commercially available sanded, unsanded or epoxy grout is acceptable, appropriate caulking material is also acceptable for wall installations. See Selection Guide, page 17. • Install and clean per manufacturer’s instructions. FLOORS • Polished finishes require a penetrating sealer (impregnator) prior to grouting. • Crossville has found that there are many lippage control systems available. For timing and method/timing of removal refer to lippage control system manufacturer’s requirements. • Use a minimum of 3mm (1/8") grout joint size due to lack of floor flatness and variable tolerances in field-cut tile panels. • For residential and light commercial applications the use of sanded grout is acceptable. For commercial applications epoxy grout is required. • The edges of the porcelain tile panels are not eased or beveled, making them susceptible to damage from heavy rolling loads and impact. Full and flush movement joints and grout joints should be specified to minimize edge impact. • Setting mortars and their recommended cure times can vary significantly from 72 hours to 7 days. Therefore it is critical to refer to the specific mortar manufacturer’s requirements for opening the floor to foot traffic. • Install and clean per manufacturer’s instructions.  .YV\[PUN To complete and finish the installation, profiles for corners, deco-bands, edges, and movement joints are available from quality suppliers such as Blanke, Custom, or Schluter (fig. 40-42). • Laminam 3+: 6.0-8.0 mm profiles recommended • Laminam 5.6: 8.0-10.0 mm profiles recommended • Follow manufacturer’s instruction for placement/insertion of profiles into the tile work. Ensure that supporting mortar is present at the edge of the tile. • For other edge finishing techniques see (fig. 43-44) See page 9 for information on movement joints. ,KNL;YLH[TLU[ZHUK7YVÄSLZ 05:;(33(;065796*,:: FIG. 40 FIG. 43 FIG. 41 FIG. 44 FIG. 42 Laminam 5.6mm Back Mitered & Epoxied Laminam 3+ and 5.6mm Using Profiles Laminam 5.6mm Field Applied Bullnose 15 7YVK\J[:WLJPÄJH[PVUZ ;,*/50*(37,9-694(5*, PHYSICAL AND CHEMICAL PROPERTIES NORM TEST METHOD Laminam3+ and 5.6 Size Laminam Maximum deviation on the side +/- 0.5 mm Size Laminam Maximum deviation on the diagonal +/- 1.0 mm Weight kg/m²Laminam 3+ Average value 8.2 5.6mm Average Value 14 Surface Quality ( % Of Tiles With No Visible Flaws) ISO 10545-2 > 95% Water Absorption ASTM C373 Average value ≤ 0.1% Breaking Load In Newtons ISO 10545-4 3+ Average value 700 5.6mm Average Value 1100 Bending Strength In N/mm² (MOR)ISO 10545-4 3+ Average value 50 5.6mm Average Value 50 MOHS Scale of Hardness UNI EN 101 ≥ 6 Resistance To Deep Abrasion ISO 10545-6 ≤ 175 mm 3 Coefficient Of Linear Thermal Expansion (10-6/°C) ISO 10545-8 6.6 Resistance To Thermal Shock ISO 10545-9 Resistant Chemical Resistance ISO 10545-13 No visible effect Stain Resistance ISO 10545-14 Class 5 Frost Resistance ISO 10545-12 Resistant Flame Spread and Smoke Development ASTM E84-12a. Flame Spread = 0 Smoke Develop = 15 *(9,(5+4(05;,5(5*, 0UP[PHS*HYLHUK4HPU[LUHUJL The single-most important step for future daily maintenance involves the complete removal of grout film/residue and construction dirt after the Laminam porcelain tile panel products have been installed. Refer to the grout manufacturer’s printed instructions for proper mixing, curing, and cleaning instructions. These are critical when working with epoxy grouts. In most cases, Laminam porcelain tile panels can be cleaned successfully by scrubbing the installation with hot water and a neutral detergent, followed by a thorough rinsing. For further details and specific recommendations please refer to Crossville’s Care and Maintenance Guide at crossvilleinc. com or call Crossville Technical Services at 931-484-2110. • Proper fork length (84”) for handling crates from the short side. • Review list and knowledge of recommended tools. • Prior to applying mortar, make sure to clean the back of the tile and the substrate to remove any dust or other contaminants. • Coverage: use wettest mortar mix ratio, directional troweling perpendicular to the long edge of the tile panel, embedding techniques. • Maximize edge coverage and minimize lippage: lippage control systems, cordless sander along the perimeter edge & between the lippage control straps. • Using the tools and best practices to minimize lippage between tiles to 1/64” (0.4mm) or less will greatly increase the finished installations ability to withstand the rolling loads used in most commercial applications. • Using grouting techniques that insure the grout joint remains full and flush will also aid in the finished installation’s ability to withstand edge impact. Particularly with epoxy grouts, use a new epoxy float with unworn sharp edges. Use steady pressure to overfill the joint and force epoxy grout into any remaining voids beneath the tile panel edge. *YP[PJHS9L]PL^7VPU[Z 05:;(33(;065796*,:: 16 469;(9(5+.96<;:,3,*;065.<0+, 4HU\MHJ[\YLY»Z7YVK\J[0UMVYTH[PVU Manufacturer Surface Preparation Mortar Systems Floors and Walls* Grout Systems Floors and Walls Caulks-Sealants Crack Isolation Membranes Ardex 888-512-7339 8+9 (tile over tile) P51 & P82 primer Liquid BackerBoard AM 100 Walls: ARDEX X77 (E90 Additive required for 3+) Floors: ARDEX X78 ARDEX FL ARDEX WA Epoxy ARDEX SX 100% Silicone ARDEX 8+9 Blanke 800-787-5055 Tested with Laticrete 254 Platinum Tested with Laticrete Spectralock Pro Premium Grout Blanke Permat BOSTIK 800-726-7845 Universal Primer Pro Bostik SL 100 or SL 175 Webcrete 95 UltraFinish Pro Reflex Mortar Big Tile & Stone Mortar EzPoxy EzClean Ceramic Tile Grout with 1900 Modified Epoxy Admix Pure Silicone Caulk Chem Calk 955SL 915FS Ultraset Advanced Gold Plus Custom 800-272-8786 Skim Coat & Patch Underlayment LevelQuik RS Self Leveling Underlayment LevelQuik Latex Primer MBP Multi-Surface Bonding Primer (tile over tile) ProLite Large Format Mortar (5.6) MegaLite Crack Prevention Mortar (3+) Polyblend Prism CEG Lite Epoxy Grout Custom Commercial 100% Silicone Caulk RedGard LATICRETE 800-243-4788 x235 Laticrete 3701 Fortified Mortar Bed Laticrete NXT Plus with NXT Primer Laticrete NXT Patch Laticrete NXT Skim Laticrete 254 Platinum Laticrete 4-XLT Laticrete Permacolor Grout Laticrete Permacolor Select Grout Laticrete Spectralock PRO Premium Grout Laticrete Latasil 100% Silicone Hydro Ban Mapei 800-992-6273 ECO Prim Grip (tile over tile) Ultraplan M-20 Plus, Primer T Mapecem Quickpatch Kerabond T/Keralastic UltraFlex LFT Ultralite S2 Ultracolor Plus Kerapoxy Mapei Mapesil 100% Silicone Sealant Mapelastic CI TEC 800-832-9023 TEC Multipurpose Primer EZ Level Premium Self Leveling Underlayment Smooth Start Self Leveling Underlayment VersaPatch Latex Modified Floor Patch and Leveler Fast Set Deep Patch TEC 3N1 Performance Mortar Ultimate Large Tile Mortar Power Grout AccuColor EFX Epoxy Grout AccuColor 100 100% Silicone Sealant HydraFlex Waterproofing Crack Isolation Mambrane * Consult mortar manufacturer for appropriate mix ratios for use with porcelain tile panels and for the proper mortar for specific applications. 17 ,?;,9069+09,*;)65+.<0+305,:>(33: 9LJVTTLUKLK7YVQLJ[9LX\PYLTLU[Z:WLJPÄJH[PVUZ Secure documentation/approval from building authority that the project complies with the provisions of the IBC (International Building Code). A: LAMINAM by Crossville® 3+ porcelain tile panels are 3 millimeters thick, with an added layer of fiberglass mesh for increased strength and flexibility. LAMINAM 5.6 porcelain tile panels are 5.6 mm thick with no additional fiberglass layer. LAMINAM 3+ and 5.6 are suitable for exterior vertical direct bond applications if the project is in compliance with the International Building Code. B: International Building Code Current Language 2009 IBC states a size limitation for exterior adhered veneers of 5 square feet with no side over 36 inches. 2012/2015 IBC (Chapter 14- Section 1405.10.2) requires that exterior adhered porcelain tile be a maximum of 24 inches in any face dimension and not more than 3 square feet in total facial area. In addition, Table 1405.2 states a minimum thickness of weather coverings (in this case porcelain tile) of ¼ inch or 6.35 mm. C: If the project design does not meet these requirements, then project architect or engineer should seek local code approval for the use of a thinner and/or larger format porcelain tile finish material for the exterior veneer. Section [A] 104.11 of 2012/2015 IBC contains the generic language for obtaining this type of approval by the local building official for alternative materials. The provisions of the code are not intended to prevent the installation of any material or prohibit any design or method of construction not specifically prescribed by this code. An alternative material, design or method of construction shall be approved where the building official finds that the proposed design is satisfactory and complies with the intent of the provisions of this code, and that the material, method or work offered is, for the purpose intended, at least the equivalent of that prescribed in this code in quality, strength, effectiveness, fire resistance, durability and safety. http://crossvilleinc.com/wordpress/wp-content/uploads/2016/02/ REQUESTFOR-APPROVAL-OF-ALTERNATIVE-MATERIALS.pdf *VKLJVTWSPHUJLHUKHWWYV]HSVMI\PSKPUNH\[OVYP[PLZ Movement Joints: Installation of LAMINAM 3+ and 5.6 on exterior walls will be in accordance with the applicable Tile Council of North America (TCNA) Handbook exterior wall details. Movement joints shall be in compliance with EJ-171 of the current TCNA Handbook. While the size and interval of movement joints must be in accordance with the TCNA guidelines and specified by the architectural/engineering authority with strict attention to the environmental demands of the project, at a minimum Crossville recommends that all joints be at least 3/16 inch and all joints treated as soft joints (no hard grouting materials in any joint)*. LAMINAM tiles have similar expansion and contraction characteristics when compared to traditional thickness porcelain tile, their reduced thickness means that they will reach maximum thermal gain and cycle through expansion/contraction more rapidly than a traditional thickness tile. For this reason, proper movement accommodation is extremely critical for success of the installation. * Note: Joint width calculations were done using a coefficient of thermal expansion of 6.5x10-6 in/in/ °C for the Laminam tiles and installation of a class 25 sealant material at 70 °F, using a high temperature of 190°F and a low temperature of -30°F. Cap Flashing: The elimination of water intrusion into the bond coat is extremely critical for success of any exterior applied veneer. Proper detailing of capping and/or flashing at the roof line or at the top of the exposed tile layer is necessary. If not properly specified and installed, efflorescence, latex leaching, and freeze thaw damage can occur. Requirement: Ensure the architect/engineer is aware of these statements and that movement joint/grout joint detail and cap flashing language is provided in the specification. 0UZ[HSSH[PVU4L[OVKZ Only setting material companies with specific installation guidelines for exterior direct bond wall applications using porcelain tile panels should be considered. Ensure that the setting material company specified can provide products and installation specifications for exterior vertical application of 3+ and 5.6 mm porcelain tile panels. A list of setting material companies with experience in this application are identified in Section 8 Requirement: Ensure the project architect/engineer has knowledge of the setting materials being used, and that those setting materials are specifically recommended for exterior vertical applications of porcelain tile panels. A pre-construction meeting and mock-up of appropriate scale is required to be in the project specification. :LSLJ[PVUVM:L[[PUN4H[LYPHS*VTWHU` LAMINAM by Crossville® – Exterior Vertical Surfaces Field Applied Direct Bond Method LAMINAM 3+ or 5.6 mm The use of full size tile panels (1Mx3M) for ground floor installations is acceptable. For installations higher than ground floor, tile panel size is limited to a maximum of 1 square meter, due to logistics, open air environments, and mortar limitations. FILO is not recommended in exterior applications Requirement: A document confirming existing code compliance or approval of alternative material by the local building official is required. This document must be provided by the project’s architectural/engineering authority. 18 LAMINAM by Crossville® has great potential in exterior vertical applications: its lightweight nature and aesthetic qualities make a great material for cladding. However, the potential for failure in outdoor environments is greatly increased when qualified labor is not utilized. Crossville recommends the use of qualified labor for the installation of LAMINAM 3+ and 5.6 mm for all installations, this becomes even more critical on a vertical exterior field (direct bond) applied installation. Suggestions for the necessary labor qualifications are listed below: • ACT – Advanced Certifications of Tile Installers • CTEF – Certified Tile Installer Program • TCAA – Trowel of Excellence • International Masonry Institute (IMI) • NTCA Five Star Contractor Program • Journeyman Tile Setter Apprenticeship Programs • And completion of Crossville Sponsored Training provided by Crossville Inc., a Crossville distributor, or other tile panel specific training authorized/approved by one of the above organizations. In addition these listings are available within Section 4.8 of this guide and in section 1.5 of the LAMINAM Guide Specification: http://crossvilleinc.com/wordpress/wp-content/ uploads/2014/05/Laminam-Guide-Specification-3-Walls- and-5_6-Floors-5-12-15.pdf Requirement: Language to be in the specification that references the labor qualifications recommended in the LAMINAM Guide Specification. 8\HSPÄLK3HIVY The foregoing suggested project requirements and/or specifications are offered as guidelines only. Each project has its own unique characteristics and requirements, and the project’s architect/engineer and design professionals must determine the appropriate requirements and specifications in each instance. Crossville makes no warranties or representations regarding the applicability of the foregoing guidelines to any given project, and assumes no liability for and shall not be responsible for the use or failure to use these guidelines. Provide this LAMINAM Technical Guide to the project architect/engineer and recommend the specification of the installation instructions for LAMINAM 3+ or 5.6 mm that are contained in the LAMINAM by Crossville® Technical Guide. Requirement: Language to be in the specification that references the Technical Guide and its installation practices. 3HTPUHT;LJOUPJHS.\PKL 19 contact Crossville Inc., 349 Sweeney Dr. Crossville, TN 38555 LaminambyCrossville.com LIT-LAMII-16 FOOD/BEVMERCHFOOD/BEVMERCH SWITCHGEAR & METER PROPANECAGE BULKCO2 TRASH RECYCLE USED COOKING OIL DRAINAGE & SANITARYSEWER EASEMENTDOC. NO. 2018-699 P.R.C.C.T. 10' WATER EASEMENT DOC. NO. 20080623000754670R.P.R.C.C.T. 24' DRAINAGE & SANITARYSEWER EASEMENT DOC. NO. 2018-699P.R.C.C.T.FRONTIER PARKWAYN. PRESTON ROAD (STATE HIGHWAY 289) LOT 3, BLOCK A VICTORY AT FRONTIERDOC. NO. 2018-699 P.R.CC.T. LOT 3, BLOCK A VICTORY AT FRONTIERDOC. NO. 2018-699 P.R.CC.T. LOT 2, BLOCK A 59,998 SQ.FT. 1.377 ACRES VICTORY AT FRONTIER DOC. NO. 2018-699 P.R.CC.T. 30' RIGHT-OF-WAY DEDICATION DOC. NO. 2018-699P.R.C.C.T.DN88°35'36"W263.84'N0°15'13"E 237.43'S89°53'39"E211.81'S1°23'32"W 117.44' S4°45'06"E 100.58' S44°42'27"E11.61'FH20'6.5'59.32'20'12'12'9'5'11' 9'TYP. 120.66' 4.9' 12'12'16'9'TYP. 17.47' 1.55' 24'20'30.5' 30' BUILDING LINE /LANDSCAPE SETBACK 24'36'30'152.04'12.34' 6' 18' 20'9'TYP.24'R10'55.18'10'5'10' 20.1' 17.13'164.37'39.4'30' BUILDING LINE /LANDSCAPESETBACK93.4'40.5'29.17'24'FIRE LANE /ACCESS, DRAINAGE UTILITY ESMT.24'FIRE LANE / ACCESS, DRAINAGE UTILITY ESMT. PROPOSED 6,487 SF BUILDING(GAS STATION: 4,971 SF) ( RESTAURANT 1,516 SF)(OUTDOOR DINING: 510 SF)FFE=524.75 5' 25' WATER ESMT. 2 1 510 SF OUTDOORSEATINGAREA PROP. FUEL CANOPY (PER FUEL PLANS) PROP. AIR/WATER /VACUUMSTATION.REFER TO ARCH. PROP. FUELVENTS PROP. 8' TRASH ENCLOSURE W/ BRICK VENEER TO MATCH BUILDING AND W/METAIL GATES EQUAL IN HIEGHT OF THEWALL ENCLOSURE PROP. PAD MOUNTEDTRANSFORMERW/ SCREENING PROP. PEDESTRIANACCESS ESMT. 404.78' TO INTERSECTION 272.8' TO INTERSECTION1,356 TO COLEMAN ST PROP. B.F.R. PROP.SERVICE DOOR PROP. PIPE BOLLARD TYP. PROP. PIPEBOLLARD TYP. PROP. B.F.R. PROP. B.F.R. EX. TRAFFICSIGNAL LIGHT EX. TRAFFICSIGNAL LIGHT PROP. B.F.R.12'18'30'30' LOADING ZONE PROP. SCREEN WALL R 3 0 ' 215.01' STORAGE24' 100' TRANSITION PROP. RIGHT TURNLANE PROP. B.F.R. PROP. B.F.R. R1 0 ' R2 2 ' 24' FDC 3 HEADLIGHT SCREENIGN HEADLIGHT SCREENIGN HEADLIGHTSCREENIGN R30'R5 4 ' R3 0 'R30'R20'R5'PROP. B.F.R.24'R5'R 3 'R3'R5 ' R2' R54'R 3 0 'R30'R225'R225'R25'R30' EXISTING CURB INELTTO BE REMOVED EXISTING SIGN TO BE RELOCATED R30'R3 0 ' R3 0 '30.93'32' R 3 ' 50.5' EXISTING POWER POLETO REMAIN EXISTING POWER POLE TO REMAIN 5'34.5' PROP. FIRE HYDRANT 10'R95'R105'R115'EXISTINGFIRE HYDRANT TO REMAIN 25'15'16.2' PROP. FIRE HYDRANTBY OTHERS PROP. FIRE HYDRANT EXISTING SANITARY SEWER MANHOLE GTPROP. CURB INLET PROP. JUNCTION BOX PROP. GRATE INLET PROP. GRATE INLET PROP.GRATE INLET PROP. DROP INLET WATER ESMT. PROP. CURB INELTR30'24'24'24'53'PROP. FIREHYDRANTBY OTHERS WATER ESMT. EXISTING SANITARY SEWER MANHOLE EXISTING SANITARYSEWER MANHOLE 5'5'PROP. 15' WATER ESMT.40.5'8'20.5'13.9'35'WATER ESMT.R3'R3'5' STREET ESMT.DATENo.REVISIONBYDATE: SHEET File No. 2018-135 2/7/2019 CHECKED: MKT DRAWN:MKT DESIGN:7 ELEVENLOT 2, BLOCK AVICTORY AT FRONTIERPROSPER, TEXAS1903 CENTRAL DRIVE, SUITE #406PHONE: 817.281.0572BEDFORD, TX 76021 WWW.CLAYMOOREENG.COMTEXAS REGISTRATION #14199 ASD PRELIMINARY CLAYMOORE ENGINEERING SITE PLAN(SHEET 1 OF 2)SP-1 COUNTY SURVEY:ABSTRACT NO. COLLIN -- CITY:STATE: TOWN OF PROSPER TEXAS LEGAL DESCRIPTION: DEVELOPER: APPLICANT: CLAYMOORE ENGINEERING, INC. 1903 CENTRAL DRIVE, SUITE #406 BEDFORD, TX 76021 PH: 817.281.0572 SURVEYOR: WINDROSE LAND SURVEYING & PLATTING 220 SOUTH ELM STREET, SUITE 200 LEWISVILLE, TX 75057 PH: 214.217.2544 SCHAFFER CONSTRUCTION 2601 NETWORK BLVD., SUITE #413 FRISCO, TEXAS 75034 PH: 972.951.7851 LOT 2, BLOCK A VICTORY AT FRONTIER DOC. NO. 2018-699 DOC. P.R.C.C.T. 1.377 ACRES (59,998 SF) 7 ELEVEN CONTACT NAME: SHANE PARTRIDGE CONTACT NAME: MATT MOORE CONTACT NAME: JACK BARTON SITE PLAN CASE #: D18-0127 0 GRAPHIC SCALE 1 inch = ft. 20 20 40 20 10 ACCORDING TO MAP NO. 48085C0120J, DATED JUNE 2, 2009 OF THE NATIONAL FLOOD INSURANCE PROGRAM MAP, FLOOD INSURANCE RATE MAP OF COLLIN COUNTY, TEXAS, FEDERAL EMERGENCY MANAGEMENT AGENCY, FEDERAL INSURANCE ADMINISTRATION, THIS PROPERTY IS WITHIN ZONE "X" (UNSHADED) AND IS NOT WITHIN A SPECIAL FLOOD HAZARD AREA. FLOODPLAIN NOTE TOWN OF PROSPER SITE PLAN GENERAL NOTES: 1. DUMPSTERS AND TRASH COMPACTORS SHALL BE SCREENED IN ACCORDANCE WITH THE ZONING ORDINANCE. 2. OPEN STORAGE, WHERE PERMITTED, SHALL BE SCREENED IN ACCORDANCE WITH THE ZONING ORDINANCE. 3. OUTDOOR LIGHTING SHALL COMPLY WITH THE LIGHTING AND GLARE STANDARDS CONTAINED WITHIN THE ZONING ORDINANCE AND SUBDIVISION ORDINANCE. 4. LANDSCAPING SHALL CONFORM TO LANDSCAPE PLANS APPROVED BY THE TOWN. 5. ALL ELEVATIONS SHALL COMPLY WITH THE STANDARDS CONTAINED WITHIN THE ZONING ORDINANCE. 6. BUILDINGS OF 5,000 SQUARE FEET OR GREATER SHALL BE 100% FIRE SPRINKLED. ALTERNATIVE FIRE PROTECTION MEASURES MAY BE APPROVED BY THE FIRE DEPARTMENT. 7. FIRE LANES SHALL BE DESIGNED AND CONSTRUCTED PER TOWN STANDARDS OR AS DIRECTED BY THE FIRE DEPARTMENT. 8. TWO POINTS OF ACCESS SHALL BE MAINTAINED FOR THE PROPERTY AT ALL TIMES. 9. SPEED BUMPS/HUMPS ARE NOT PERMITTED WITHIN A FIRE LANE. 10. HANDICAPPED PARKING AREAS AND BUILDING ACCESSIBILITY SHALL CONFORM TO THE AMERICANS WITH DISABILITIES ACT (ADA) AND WITH THE REQUIREMENTS OF THE CURRENT, ADOPTED BUILDING CODE. 11. ALL SIGNAGE IS SUBJECT TO BUILDING OFFICIAL APPROVAL. 12. ALL FENCES AND RETAINING WALLS SHALL BE SHOWN ON THE SITE PLAN AND ARE SUBJECT TO BUILDING OFFICIAL APPROVAL. 13. ALL EXTERIOR BUILDING MATERIALS ARE SUBJECT TO BUILDING OFFICIAL APPROVAL AND SHALL CONFORM TO THE APPROVED FAÇADE PLAN. 14. SIDEWALKS OF NOT LESS THAN SIX (6’) FEET IN WIDTH ALONG THOROUGHFARES AND COLLECTORS AND FIVE (5’) IN WIDTH ALONG RESIDENTIAL STREETS, AND BARRIER FREE RAMPS AT ALL CURB CROSSINGS SHALL BE PROVIDED PER TOWN STANDARDS. 15. APPROVAL OF THE SITE PLAN IS NOT FINAL UNTIL ALL ENGINEERING PLANS ARE APPROVED BY THE ENGINEERING DEPARTMENT. 16. SITE PLAN APPROVAL IS REQUIRED PRIOR TO GRADING RELEASE. 17. ALL NEW ELECTRICAL LINES SHALL BE INSTALLED AND/OR RELOCATED UNDERGROUND. 18. ALL MECHANICAL EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW IN ACCORDANCE WITH THE ZONING ORDINANCE. 19. ALL LANDSCAPE EASEMENTS MUST BE EXCLUSIVE OF ANY OTHER TYPE OF EASEMENT. 20. IMPACT FEES WILL BE ASSESSED IN ACCORDANCE WITH THE LAND USE CLASSIFICATION(S) IDENTIFIED ON THE SITE DATA SUMMARY TABLE; HOWEVER, CHANGES TO THE PROPOSED LAND USE AT THE TIME CO AND/OR FINISH-OUT PERMIT MAY RESULT IN ADDITIONAL IMPACT FEES AND/OR PARKING REQUIREMENTS. 21. ALL DIMENSIONS ARE TO FACE OF CURB UNLESS OTHERWISE NOTED. 22. THE APPROVAL OF A SITE PLAN SHALL BE EFFECTIVE FOR A PERIOD OF EIGHTEEN (18) MONTHS FROM THE DATE OF APPROVAL BY THE PLANNING & ZONING COMMISSION, AT THE END OF WHICH TIME THE APPLICANT MUST HAVE SUBMITTED AND RECEIVED APPROVAL OF ENGINEERING PLANS AND BUILDING PERMITS. IF THE ENGINEERING PLANS AND BUILDING PERMITS ARE NOT APPROVED, THE SITE PLAN APPROVAL, TOGETHER WITH ANY PRELIMINARY SITE PLAN FOR THE PROPERTY, IS NULL AND VOID. BENCHMARK: 1. AN 'X' CUT ON A CURB INLET WHICH BEARS S13°47'E,84.93' FROM THE SOUTHEAST PROPERTY CORNER. POSTED ELEVATION: 708.16' 2. AN 'X' CUT SET WHICH BEARS S02°38'W, 458.75' FROM THE SOUTHWEST PROPERTY CORNER. ELEVATION:704.14 WATER METER SCHEDULE ID TYPE SIZE NO. DOM.2" 1 IRR. 1 1/2"1 1 2 *NO 100-YEAR FLOODPLAIN EXISTS ON THE SITE* LEGEND 6" MEDIUM DUTY CONCRETE PAVEMENT. 5" LIGHT DUTY CONCRETE PAVEMENT. 8" DUMPSTER AREA CONCRETE PAVEMENT. PROPOSED CONCRETE SIDEWALK. PROPOSED CONCRETE CURB AND GUTTER. PARKING COUNT PROPOSED SIDEWALK PER CITY STANDARDS PROPOSED DRIVEWAY PAVEMENT PER CITY STANDARDS. N.T.S. VICINITY MAP NN PRESTON RDFRONTIER PKWY SITE E PROSPER TRAIL PROP. MUTUAL ACCESS DRIVE TO NEXT MEDIAN OPENING FUTURE MEDIAN (BY OTHERS) GREASE TRAP 1000 gal.13MATCHLINE 24' DRAINAGE & SANITARYSEWER EASEMENT DOC. NO. 2018-699P.R.C.C.T. LOT 3, BLOCK AVICTORY AT FRONTIER DOC. NO. 2018-699P.R.CC.T.24'24'PROP. FIRE HYDRANT BY OTHERS WATER ESMT. EXISTING SANITARY SEWER MANHOLE EXISTING SANITARYSEWER MANHOLE DATENo.REVISIONBYDATE: SHEET File No. 2018-135 2/7/2019 CHECKED: MKT DRAWN:MKT DESIGN:7 ELEVENLOT 2, BLOCK AVICTORY AT FRONTIERPROSPER, TEXAS1903 CENTRAL DRIVE, SUITE #406PHONE: 817.281.0572BEDFORD, TX 76021 WWW.CLAYMOOREENG.COMTEXAS REGISTRATION #14199 ASD PRELIMINARY CLAYMOORE ENGINEERING SITE PLAN(SHEET 2 OF 2)SP-2 COUNTY SURVEY:ABSTRACT NO. COLLIN -- CITY:STATE: TOWN OF PROSPER TEXAS LEGAL DESCRIPTION: DEVELOPER: APPLICANT: CLAYMOORE ENGINEERING, INC. 1903 CENTRAL DRIVE, SUITE #406 BEDFORD, TX 76021 PH: 817.281.0572 SURVEYOR: WINDROSE LAND SURVEYING & PLATTING 220 SOUTH ELM STREET, SUITE 200 LEWISVILLE, TX 75057 PH: 214.217.2544 SCHAFFER CONSTRUCTION 2601 NETWORK BLVD., SUITE #413 FRISCO, TEXAS 75034 PH: 972.951.7851 LOT 2, BLOCK A VICTORY AT FRONTIER DOC. NO. 2018-699 DOC. P.R.C.C.T. 1.377 ACRES (59,998 SF) 7 ELEVEN CONTACT NAME: SHANE PARTRIDGE CONTACT NAME: MATT MOORE CONTACT NAME: JACK BARTON SITE PLAN CASE #: D18-0127 0 GRAPHIC SCALE 1 inch = ft. 20 20 40 20 10 ACCORDING TO MAP NO. 48085C0120J, DATED JUNE 2, 2009 OF THE NATIONAL FLOOD INSURANCE PROGRAM MAP, FLOOD INSURANCE RATE MAP OF COLLIN COUNTY, TEXAS, FEDERAL EMERGENCY MANAGEMENT AGENCY, FEDERAL INSURANCE ADMINISTRATION, THIS PROPERTY IS WITHIN ZONE "X" (UNSHADED) AND IS NOT WITHIN A SPECIAL FLOOD HAZARD AREA. FLOODPLAIN NOTE TOWN OF PROSPER SITE PLAN GENERAL NOTES: 1. DUMPSTERS AND TRASH COMPACTORS SHALL BE SCREENED IN ACCORDANCE WITH THE ZONING ORDINANCE. 2. OPEN STORAGE, WHERE PERMITTED, SHALL BE SCREENED IN ACCORDANCE WITH THE ZONING ORDINANCE. 3. OUTDOOR LIGHTING SHALL COMPLY WITH THE LIGHTING AND GLARE STANDARDS CONTAINED WITHIN THE ZONING ORDINANCE AND SUBDIVISION ORDINANCE. 4. LANDSCAPING SHALL CONFORM TO LANDSCAPE PLANS APPROVED BY THE TOWN. 5. ALL ELEVATIONS SHALL COMPLY WITH THE STANDARDS CONTAINED WITHIN THE ZONING ORDINANCE. 6. BUILDINGS OF 5,000 SQUARE FEET OR GREATER SHALL BE 100% FIRE SPRINKLED. ALTERNATIVE FIRE PROTECTION MEASURES MAY BE APPROVED BY THE FIRE DEPARTMENT. 7. FIRE LANES SHALL BE DESIGNED AND CONSTRUCTED PER TOWN STANDARDS OR AS DIRECTED BY THE FIRE DEPARTMENT. 8. TWO POINTS OF ACCESS SHALL BE MAINTAINED FOR THE PROPERTY AT ALL TIMES. 9. SPEED BUMPS/HUMPS ARE NOT PERMITTED WITHIN A FIRE LANE. 10. HANDICAPPED PARKING AREAS AND BUILDING ACCESSIBILITY SHALL CONFORM TO THE AMERICANS WITH DISABILITIES ACT (ADA) AND WITH THE REQUIREMENTS OF THE CURRENT, ADOPTED BUILDING CODE. 11. ALL SIGNAGE IS SUBJECT TO BUILDING OFFICIAL APPROVAL. 12. ALL FENCES AND RETAINING WALLS SHALL BE SHOWN ON THE SITE PLAN AND ARE SUBJECT TO BUILDING OFFICIAL APPROVAL. 13. ALL EXTERIOR BUILDING MATERIALS ARE SUBJECT TO BUILDING OFFICIAL APPROVAL AND SHALL CONFORM TO THE APPROVED FAÇADE PLAN. 14. SIDEWALKS OF NOT LESS THAN SIX (6’) FEET IN WIDTH ALONG THOROUGHFARES AND COLLECTORS AND FIVE (5’) IN WIDTH ALONG RESIDENTIAL STREETS, AND BARRIER FREE RAMPS AT ALL CURB CROSSINGS SHALL BE PROVIDED PER TOWN STANDARDS. 15. APPROVAL OF THE SITE PLAN IS NOT FINAL UNTIL ALL ENGINEERING PLANS ARE APPROVED BY THE ENGINEERING DEPARTMENT. 16. SITE PLAN APPROVAL IS REQUIRED PRIOR TO GRADING RELEASE. 17. ALL NEW ELECTRICAL LINES SHALL BE INSTALLED AND/OR RELOCATED UNDERGROUND. 18. ALL MECHANICAL EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW IN ACCORDANCE WITH THE ZONING ORDINANCE. 19. ALL LANDSCAPE EASEMENTS MUST BE EXCLUSIVE OF ANY OTHER TYPE OF EASEMENT. 20. IMPACT FEES WILL BE ASSESSED IN ACCORDANCE WITH THE LAND USE CLASSIFICATION(S) IDENTIFIED ON THE SITE DATA SUMMARY TABLE; HOWEVER, CHANGES TO THE PROPOSED LAND USE AT THE TIME CO AND/OR FINISH-OUT PERMIT MAY RESULT IN ADDITIONAL IMPACT FEES AND/OR PARKING REQUIREMENTS. 21. ALL DIMENSIONS ARE TO FACE OF CURB UNLESS OTHERWISE NOTED. 22. THE APPROVAL OF A SITE PLAN SHALL BE EFFECTIVE FOR A PERIOD OF EIGHTEEN (18) MONTHS FROM THE DATE OF APPROVAL BY THE PLANNING & ZONING COMMISSION, AT THE END OF WHICH TIME THE APPLICANT MUST HAVE SUBMITTED AND RECEIVED APPROVAL OF ENGINEERING PLANS AND BUILDING PERMITS. IF THE ENGINEERING PLANS AND BUILDING PERMITS ARE NOT APPROVED, THE SITE PLAN APPROVAL, TOGETHER WITH ANY PRELIMINARY SITE PLAN FOR THE PROPERTY, IS NULL AND VOID. BENCHMARK: 1. AN 'X' CUT ON A CURB INLET WHICH BEARS S13°47'E,84.93' FROM THE SOUTHEAST PROPERTY CORNER. POSTED ELEVATION: 708.16' 2. AN 'X' CUT SET WHICH BEARS S02°38'W, 458.75' FROM THE SOUTHWEST PROPERTY CORNER. ELEVATION:704.14 *NO 100-YEAR FLOODPLAIN EXISTS ON THE SITE* LEGEND 6" MEDIUM DUTY CONCRETE PAVEMENT. 5" LIGHT DUTY CONCRETE PAVEMENT. 8" DUMPSTER AREA CONCRETE PAVEMENT. PROPOSED CONCRETE SIDEWALK. PROPOSED CONCRETE CURB AND GUTTER. PARKING COUNT PROPOSED SIDEWALK PER CITY STANDARDS PROPOSED DRIVEWAY PAVEMENT PER CITY STANDARDS.N.T.S. VICINITY MAP NN PRESTON RDFRONTIER PKWY SITE E PROSPER TRAIL MATCHLINEPROP. DEVLOPMENT (BY OTHERS)PROP. PAVEMENT(BY OTHERS) February 12, 2019 Ms. Pamela Clark Town of Prosper 200 S. Main Street Prosper, TX 75078 Re: Victory at Frontier, Block A, Lot 2 – Façade Exception Request Dear Pamela, Please let this letter provide the support for the façade exception request on the proposed 7-Eleven project to be located at the SWC of Frontier Parkway and Preston Road. We have provided the colored elevations based on discussions with Staff and the comments received to date. Below are the criteria noted in the ordinance and our team’s feedback to each requirement. 1. Is unique architectural expression This project is one of five new prototypes being developed by 7-Eleven across the Country with this larger store footprint. This project will be a complete overhaul in the design and functionality both inside and outside to meet this type of market’s expectations. Each of the five stores being developed are individually unique and are being tailored to the locations in which they are developed in design, product offerings, etc. This project will be a foundation that is used for future design concepts. This architecture will be one of a kind, making this unique to Prosper. 2. Includes unique building styles and materials This building will contain porcelain tile products. While porcelain has been a popular interior finish for years, it has been developed as an exterior material, offering an extensive color palette that is attractive and extremely durable. There are more designers, owners, developers going this direction for their projects. We are also working to incorporate wood slats, stone walls, and metal canopies to create a unique look to this building. 3. Is consistent with high quality development It is our team’s sincere belief that this building meets and exceeds the quality and expectations set forth in the Town ordinances. Prosper was chosen as one of five locations for this exciting new concept for 7-Eleven because of the quality that this Town expects and our team has strived to exceed those requirements. 4. Is or would be visually harmonious with existing or proposed nearby buildings Our team reviewed the previously approved elevations for the Victory development located at the far south end of this parent tract. Our team worked with the same family of colors to create a nice complementary color pallet with the other building. 5. Has obvious merit based upon the quality and durability of the materials; Our team believes the materials presented are durable and exude quality. We have worked with the manufacturers of the porcelain tile to address the climate concerns in Texas for a porcelain tile material as well as the wood accent materials that are shown. The rest of the materials are common to developments in the DFW area. 6. Represents an exterior building material that is in keeping with the intent of this chapter to balance the abovementioned objectives. Based on the discussion points above, we believe that the colored elevations presented as part of this request meet the intent of the objectives and provide a project that the Town can support. Sincerely, Claymoore Engineering, Inc. Matt Moore Page 1 of 4 To: Planning & Zoning Commission Item No. 5 From: Scott Ingalls, AICP, Senior Planner Through: Alex Glushko, AICP, Planning Manager Re: Planning & Zoning Commission Meeting – February 19, 2019 Agenda Item: Conduct a Public Hearing, and consider and act upon a request to amend Planned Development-75 (PD-75), generally to modify the Office District, on 67.7± acres, located on the northwest corner of Prosper Trail and Dallas Parkway. (Z18-0019). Description of Agenda Item: The zoning and land use of the surrounding properties are as follows: Zoning Current Land Use Future Land Use Plan Subject Property Planned Development-75- Single Family, Office, and Retail Undeveloped Tollway District North Planned Development-36- SF-10/12.5 and Commercial Corridor Single Family Residential (Legacy Gardens) and Undeveloped Medium Density Residential Tollway District East Commercial Corridor Undeveloped Tollway District South Planned Development-66- Single Family and Retail Single Family Residential (Star Trail) and Undeveloped Medium Density Residential Tollway District West Planned Development-60- SF-10 Single Family Residential Low Density Residential In October, 2015, the Town Council approved Planned Development-75 (PD-75) for a mixed use development including a Single Family-15 District, Retail District, and Office District. The Office District depicted three (3) buildings totaling 44,400 square feet and included elevations for the proposed buildings. The developer is now proposing to modify the Office District by revising Exhibit D to depict fourteen (14) smaller buildings totaling 67,392 square feet. Exhibit D1 provides additional detail Prosper is a place where everyone matters. PLANNING Page 2 of 4 of the site and proposed improvements. The larger overall building square footage is allowed under the existing Development Standards, Exhibit C, which will not be amended. Existing Office District Exhibit D Proposed Office District Exhibit D Page 3 of 4 Exhibit F shows the proposed Office District building elevations for the fourteen (14) office buildings. The proposed elevations comply with the existing Development Standards, Exhibit C, and the Office development standards of the Zoning Ordinance. Existing Office District Exhibit F Proposed Office District Exhibit F A revised Exhibit G has been provided that illustrates required tree and shrub planting for the revised office building configuration specifically along the western and northern property lines which abut single family residential zoned property. Town staff believes these amendments are reasonable and will allow the developer flexibility to construct an office development that will attract a broader customer base and yet maintain a high quality development. Therefore, staff recommends approval of the proposed amendments. Future Land Use Plan – The Future Land Use Plan recommends Tollway District for the property; the proposed amendment conforms to the Future Land Use Plan. Thoroughfare Plan – The property has direct access to existing Prosper Trail, an ultimate six- lane divided thoroughfare, and future Shawnee Trail, an ultimate four-lane divided thoroughfare. The zoning exhibit complies with the Thoroughfare Plan. Water and Sanitary Sewer Services – Water and sanitary sewer service will need to be extended to the property. Access – The property currently has access from Prosper Trail and future Shawnee Trail. Adequate access is provided to the property. Page 4 of 4 Schools – This property is served by the Prosper Independent School District. It is not anticipated that a school site will be needed on this property. Parks – This property is not needed for a park. Environmental Considerations – There is 100-year floodplain on the property. Legal Obligations and Review: Notification was provided to neighboring property owners, as required by state law. Town staff has received one Public Hearing Notice Reply Form; not in opposition to the request. Attached Documents: 1. Location and Zoning Maps 2. Proposed Exhibits A, B, C, D, D1, E, F, and G 3. Public Hearing Reply Form Town Staff Recommendation: Town staff recommends the Planning & Zoning Commission approve this amendment request. Town Council Public Hearing: Upon a recommendation by the Planning & Zoning Commission, a Public Hearing on this item will be scheduled for the Town Council at their Regular meeting on March 12, 2019. Z18-0019 PROSPER TRL DALLAS PKWYKIRKWOOD LNSHAWNEE TRLWYNNE AVE CARUTH DR LAKE TRAIL LNINWOOD LN ARMSTRONG LNMAPLEWOOD DRRUSTIC LN PRESCOTT DRSHENANDOAH ST STARGAZER WAYS T A R M E A D O W D RLONG GROVE LNPINTAIL LNBIRDSONG LN BROOKFIELD DRBEVERLY DRFOXGLEN DREUCLID DRFOX RIDGE TRL OVERLOOK DRSAGEBRUSH DR KINGS VIEW DR WHITE TAIL DR GENTLE KNOLL LNIVY GLEN C T RIVER ROCK LN WINDROCK LNQUAIL CREEK LNSOUTH GATE LNCORAL RIDGE CT CARILLON PL STARLIGHT WAY±0 560 1,120280 Feet Z18-0019 PD-66 PD-36 PD-8 PD-33PD-66 PD-63 PD-75 PD-44 PD-35 PD-8 PD-66 PD-75 PD-60 PD-74 PD-75 SF O A R R CC C CC SF-10/12.5 SF-10 R SF MF CC SF-15 O SF-15 SF-10 CC SF-10 SF-15 CC PROSPER TRL DALLAS PKWYKIRKWOOD LNSHAWNEE TRLWYNNE AVE CARUTH DR LAKE TRAIL LNINWOOD LN ARMSTRONG LNRUSTIC LN PRESCOTT DRSHENANDOAH ST STARGAZER WAYS T A R M E A D O W D RLONG GROVE LNPINTAIL LNBIRDSONG LN BROOKFIELD DRBEVERLY DR FOXGLEN DREUCLID DRFOX RIDGE TRL OVERLOOK DRSAGEBRUSH DR RIDGECROSS RD WHITE TAIL DR GENTLE KNOLL LNIVY GLEN C T RIVER ROCK LN CLUB OAK CT QUAIL CREEK LN GOLDEN SUNSET CTSOUTH GATE LNCARILLON PL K O B Y C I RSTARLIGHT WAY±0 560 1,120280 Feet ã 7.500 AC OFFICE TRACTBEING a tract of land situated in the Collin County School Land #12 Survey, Abstract Number 147, Town of Prosper, Collin County,Texas, being a portion of the tract described by the deed to Prosper 67 Partners, LTD., recorded under Instrument Number20121031001392700, Official Public Records, Collin County, Texas (OPRCCT), the subject tract being more particularly described asfollows (Bearings for this description are based on the State Plane Coordinate System, Texas North Central Zone 4202, NorthAmerican Datum of 1983):COMMENCING at a 5/8 inch rebar found at the northwest corner of said Prosper 67 Partners tract, being a southeasterly corner ofthe tract described by the deed to BGY Prosper 221, LLC, recorded under Instrument Number 20171121001544530, OPRCCT;THENCE with the west line of said Prosper 67 Partners, LTD. Tract and the southerly east line of said BGY Prosper 221, LLC tract,SOUTH 00 degrees 36 minutes 44 seconds EAST, a distance of 928.60 feet to a 5/8 inch rebar with cap stamped “RPLS 6059”(hereinafter “capped rebar set”) at the northwest corner and point of beginning of the herein described tract;THENCE through the interior of said Prosper 67 Partners, LTD. Tract, NORTH 89 degrees 27 minutes 50 seconds EAST, a distanceof 745.36 feet to a capped rebar set on the west line of Shawnee Trail, a variable width right-of-way dedicated by plat recordedunder Document Number 2018-408, O.P.R.C.C.T., said point being the beginning of a non-tangent curve to the left, having a radiusof 1145.00 feet, a central angle of 06 degrees 39 minutes 11 seconds, and a chord bearing and distance of SOUTH 02 degrees 46minutes 06 seconds WEST, 132.88 feet;THENCE with the west right-of-way of said Shawnee Trail, the following calls:Along the arc of said curve, an arc distance of 132.95 feet to a capped rebar set;SOUTH 00 degrees 33 minutes 39 seconds EAST, a distance of 15.00 feet to a capped rebar set;SOUTH 03 degrees 15 minutes 12 seconds WEST, a distance of 150.33 feet to a capped rebar set;SOUTH 00 degrees 33 minutes 39 seconds EAST, a distance of 125.00 feet to a point for corner from which a 5/8 inch rebarbearsSOUTH 28 degrees EAST, 0.36 feet;SOUTH 44 degrees 26 minutes 21 seconds WEST, a distance of 35.36 feet to a 5/8 inch rebar with cap stamped "JONES |CARTER" found (hereinafter "capped rebar found") on the north right-of-way of Prosper Trail, as dedicated by said DocumentNumber 2018-408;THENCE with the north right-of-way of said Prosper Trail, the following calls:SOUTH 89 degrees 26 minutes 21 seconds WEST, a distance of 507.11 feet to a capped rebar found at the beginning of atangent curve to the right, having a radius of 503.00 feet, a central angle of 08 degrees 22 minutes 26 seconds, and a chordbearing and distance ofNORTH 86 degrees 21 minutes 33 seconds WEST, 73.45 feet;Along the arc of said curve, an arc distance of 73.52 feet to a capped rebar found at the beginning of a reverse curve, having aradius of 527.02 feet, a central angle of 08 degrees 22 minutes 27 seconds, and a chord bearing and distance of NORTH 86degrees 22 minutes 25 seconds WEST, 76.96 feet;Along the arc of said curve, an arc distance of 77.03 feet to a capped rebar found;SOUTH 89 degrees 26 minutes 21 seconds WEST, a distance of 45.13 feet to a capped rebar found on the west line of saidProsper 67 Partners, LTD. Tract, same being the east line of said BGY Prosper 221, LLC tract, from which a 1/2 inch rebar withred cap found bears SOUTH 00 degrees 36 minutes WEST, a distance of 11.36 feet;THENCE with the west line of said Prosper 67 Partners, LTD. tract and the east line of said BGY Prosper 221, LLC tract, NORTH00 degrees 36 minutes 44 seconds WEST, a distance of 436.98 feet, returning to the POINT OF BEGINNING and enclosing 7.500acres (326,691 square feet) of land, more or less.CASE No. Z18-0019EXHIBIT A+/- 7.5 ACRES OF LANDPD-75-RETAILPD-75-SF-15RISLAND PROSPER 221 LLCRISLAND PROSPER 221 LLC -Exhibit B- Statement of Intent I. Statement of Intent A. Overall Intent This 67 acre property is intended to be developed in a manner that will allow flexibility of uses within the categories of retail, commercial and residential zones. The development will include recreational and detention space and will grow into an active community of mixed uses. B. Description of Property Located at the northwest intersection of the Dallas Parkway and Prosper Trail, this 67.7 acre tract is owned by Avex Group. Shawnee Trail, a four (4) lane divided minor thoroughfare runs north and south through the middle of the property and will provide access to the proposed uses within the development. Driveway access for the development will also be taken off Prosper Trail on the southern boundary of the site and Dallas Parkway along the eastern boundary. A floodplain, open space and detention basin runs east and west through the site along the creek. With the exception of the existing 20 foot wide paving for Prosper Trail along the southern boundary, the subject property is currently vacant. To the north and west of the site is a proposed single family development, Legacy Crossing (PD-36 and PD-60). To the south is the proposed 880 acre Villages of Star Trail, a Planned Development (PD-66) which incorporates single family, office, retail and commercial zoning. Exhibit A and Exhibit D depict the location and boundary of the project. C. Description of Proposed Development The location of this project, at the intersection of a major highway and two thoroughfares, lends itself well for commercial, retail, and/or office development. A mixture of small pad sites, retail centers and large big box retail tracts will allow for a variety of uses, including banks, small offices, restaurants, grocery stores, etc. Additionally, with the site’s close proximity to residential developments, there is an opportunity for large single family lots in the northwest corner of the subject property. The proposed multiple uses are divided into three (3) main categories: office, retail and single family residential. As shown in Exhibit D, the portion of the property west of Shawnee Trail will be single family residential to the north and neighborhood service to the south. The eastern portion of the property, between the future Shawnee Trail and Dallas Parkway, is composed of retail and commercial uses. As mentioned in the previous section, a large east/west detention and open space area divides the property, creating two detention areas, +6.2 acres of detention/open space to the west of Shawnee Trail and +8.9 acres on the eastern side of it. As shown on Exhibit D, a hike and bike trail connecting to the trail in the neighboring development will extend through the property, along the creek. In addition to creating recreational opportunities within the development, the detention/open space areas provide a significant buffer between the residential and neighborhood service areas, as well as between the varying scales of the commercial development. II. Current Zoning and Land Uses A. Current Zoning Classification Between Dallas Parkway and the boundary of the proposed minor thoroughfare, Shawnee Trail, the current zoning is CC-Commercial Corridor District. To the west of the proposed minor thoroughfare boundary, the majority of the property is currently zoned SF-15. 1 B. Future Land Use Plan The Future Land Use plan designates the eastern portion of the property as Dallas North Tollway District and the western portion as Medium Density Residential. C. Compatibility with Comprehensive Plan The current designations shown on the Future Land Use map for this area, Medium Density Residential and Dallas North Tollway District, are defined within the Comprehensive Plan to include uses within the classifications of office, retail and residential. In regards to Medium Density Residential, the designation requires lot sizes with a range between 12,500 square feet and 20,000 square feet. In addition to the lot size, the density for Medium Density Residential zones is recommended to be between 1.6-2.5 dwelling units per acre. The average lot size on the proposed concept plan in approximately 15,000 square feet with an approximate density of 1.9 units per acre. This is within the parameters of both the proposed SF-12 zoning district as well as the standards set forth within the Comprehensive Plan. Within the area designated as the Dallas North Tollway District, the proposal of various retail, banking, and restaurant spaces throughout the development meets the intention of providing multiple uses that benefit residents, commuters and visitors of the area. As the area continues to grow and develop, the demand for such spaces will increase, and the location of the site at the intersection of the Tollway and a Minor Thoroughfare will create the convenient access that is conducive to the needs of everyone. 1 Exhibit C- Planned Development Standards Conformance with the Town’s Zoning Ordinance and Subdivision Ordinance: Except as otherwise set forth in these Development Standards, the regulations of the Town’s Zoning Ordinance (Ordinance No. 05-20 as it exists or may be amended) and the Subdivision Ordinance (As it exists or may be amended) shall apply. Tract A-Single Family 15 District A.1 Except as noted below, Tract A shall develop in accordance with the Single Family 15 District as it exists or may be amended. A.2 Uses. The site shall be limited to the following permitted uses. 1. Accessory Building 2. Day Care Center, In-Home C 3. Farm or Ranch 4. Home Occupation C 5. Homebuilder Marketing Center C 6. House of Worship 7. Model Home 8. Municipal Uses Operated by the Town of Prosper 9. Park or Playground 10. Private Street Development C 11. School, Public 12. Single Family Dwelling, Detached A.3 Density: Maximum of 2.5 dua, per gross acreage. A.4 Regulations 1. Minimum Side Yard – Ten (10) feet, fifteen (15) feet on corner adjacent to a side street 2. Minimum Front Yard – Thirty (30) feet, twenty five (25) on cul-de-sac lots 3. Minimum Rear Yard – Twenty (20) feet 4. Minimum Lot Area – a. A maximum of three (3) lots within Tract A may be less than 15,000 square feet. These lots must have a minimum square footage of thirteen thousand five hundred (13,500). b. Minimum average lot area of all lots within Tract A must be no less than fifteen thousand (15,000) square feet 5. Minimum Lot Width – One hundred (100) feet 6. Minimum Lot Depth – One hundred and thirty five (135) feet i. When located on a cul-de-sac, the lot depth may be a minimum of one hundred and twenty five (125) feet, so long as the minimum lot area is met 7. Minimum Dwelling Area – Two thousand (2,000) square feet 8. Maximum Impervious Coverage – a. The cumulative area of any driveway plus any impermeable surface area located between the front property line and any front building wall shall not exceed fifty (50) percent of the area between the front property line and any front building wall. The front wall of a j-swing wall can be used to meet the requirement. 9. Alternating Single Family Plan Elevations (Anti-Monotony) 2 a. A minimum of four (4) distinctly different home elevations shall be built on the same side of the street. Similar elevations shall not face each other. The same elevation shall not be within three (3) homes of each other on the same side of the street. b. Different exterior elevations can be met by meeting at least two of the following criteria: i. Different roof forms/profiles ii. Different façades consisting of different window and door style and placement iii. Different entry treatments such as porches and columns iv. Different number of stories 10. Open Space Requirements: a. Within the SF-15 District, a minimum of five (5) acres of open space is required. This space may include detention and floodplain areas and must contain landscaping and amenities where applicable. i. An eight (8) foot wide hike and bike trail connecting to the overall trail plan must be located with this area. ii. Landscaping (Trees and/or shrubs) must be planted along the northern edge of the hike and bike trail, between the trail and the back of the residential lots. 11. Additional Masonry Requirements: a. Excluding windows, any portion of an upper story facing a street shall be constructed of 100% masonry. b. Chimneys shall be clad with 100% clay fired brick, natural or manufactured stone or stucco. 12. Garage Requirements: a. In no instance shall a garage door directly facing a street be less than twenty five (25) feet from the property line. b. Garage doors directly facing a street shall not occupy more than fifty percent (50%) of the width of the front façade of the house. c. Garage doors directly facing a street shall be located a minimum of five (5) feet behind the main front façade of the house. d. Where a home has three (3) or more garage/enclosed parking spaces, no more than two (2) garage doors shall face the street, unless the garage doors are located behind the main structure. 13. Fencing Requirements: a. Privacy fences on single family residential lots shall be located a minimum of ten (10) feet behind the front elevation of the main building and shall not exceed eight (8) feet in height above grade. b. Wood fences shall be board on board with a top rail. A common fence stain color shall be established for the development by the developer/HOA. c. Fences adjacent to open space and hike and bike trails shall be ornamental metal, tubular steel or split rail. d. Fences on corner lots shall be ornamental metal, tubular steel or split rail. 14. Carports are prohibited. 15. Additional Tree Requirements. a. A minimum of two (2), four (4) inch caliper trees shall be planted in the side yard of a corner lot. Where more than two (2) trees are required per lot, the side yard corner lot trees may be used to meet the requirement. 3 Tract B Office District B.1 Except as noted below, Tract B shall develop in accordance with the Office District as it exists or may be amended. B.2 Uses. Uses shall be permitted in accordance with the Office District with the exception of the following uses which shall be prohibited: 1. Athletic Stadium or Field, Public 2. Cemetery or Mausoleum 3. Civic/Convention Center 4. Commercial Amusement, Indoor 5. Golf Course and/or Country Club 6. Private Boarding School 7. Recycling Collection Point 8. Rehabilitation Care Institution 9. Restaurants with Drive-up or Drive-through service 10. School District Bus Yard 11. Sewage Treatment Plant/Pumping Station 12. Telephone Exchange 13. Utility Distribution/Transmission Facility 14. Water Treatment Plant B.3 Regulations 1. Lot Coverage – Maximum of thirty (30) percent a. Lot coverage is defined as the area covered by the building footprint 2. Maximum Floor Area – Ten thousand (10,000) square feet b. The maximum floor area may exceed ten thousand (10,000) square feet under either of the following conditions i. The entire structure is in excess of two hundred and fifty (250) feet from a residential lot. ii. The structure is separated from a residential lot by a public right of way 3. Landscape Buffer – a. A minimum of a twenty-five (25) foot landscape buffer shall be required when adjacent to any residential zoning district. i. Planting Standards within Buffer 1. Four (4) inch caliper large evergreen trees shall be planted every thirty (30) feet on center 2. Two (2) to three (3) inch caliper evergreen ornamental trees shall be staggered every fifteen (15) feet to provide a solid living screen. a. When the required open space for the planned development is located between the office and residential zones, it may count toward the required 25’ buffer, provided that the above mentioned landscape requirements are met. b. A minimum of a twenty-five (25) foot landscape buffer shall be required along Shawnee Trail and Prosper Trail i. Planting Standards within Buffer 1. One (1) – Four (4) inch caliber evergreen trees shall be planted per thirty (30) linear feet of frontage. These trees may be planted in groups with appropriate spacing for species. 2. One (1) – Three (3) inch caliper ornamental tree shall be planted per thirty (30) linear feet of frontage. These trees may be planted in groups with appropriate spacing for species. 4 3. A minimum of fifteen (15) shrubs with a minimum size of five (5) gallons each shall be planted in the landscape area for every thirty (30) feet of frontage. Where parking spaces face the right-of-way, a second row of shrubs may be required in order to further screen the parking lot from view. 4. In addition to the tree and shrub requirements, berms with a minimum height of two (2) feet must be provided within the landscape buffer. 4. Façade Plan and Architectural Style Approval a. Upon submittal of the first Preliminary Site Plan and/or Site Plan, a detailed style/material plan shall be submitted along with the Façade Plan for Planning and Zoning Commission and Town Council approval. B.4 Design Guidelines 1. Architectural standards a. Buildings must be one hundred percent (100%) masonry, excluding windows, doors, trim and accent materials. i. Masonry materials include brick, stone, and/or stucco ii. The primary material shall be brick and/or stone. Stucco may be used as an accent not to exceed twenty percent (20%) of any exterior elevation. b. The style of all buildings must be consistent and in keeping with the style of the entire Planned Development as shown on the conceptual elevations (Exhibit G) c. All materials and exterior colors shall be compatible with those used throughout the development as well as any similar developments adjacent to the Planned Development d. Building articulation is required on all elevations. This may be achieved through recessed or projecting architectural elements, variation in roof line, etc. e. No single finish shall cover more than eighty (80) percent of the front of any building f. Pitched Roofs are required for all development within Tract B i. Buildings less than 5,000 sq. ft. shall have a minimum roof pitch of 8:12 ii. Buildings less than 10,000 sq. ft. shall have a minimum roof pitch of 6:12 iii. Any building 10,000 sq.ft. or larger must have a minimum roof pitch of 4:12 2. Screening a. Service, Mechanical and Utility Equipment i. All service, mechanical and/or utility equipment shall be completely screened from public view by architectural screens, fences and/or landscaping. ii. Trash cans and dumpster locations shall be permanently fenced or screened with enclosures rendering these functions hidden from public view. These enclosures shall be reinforced masonry and must match the materials used on the primary structure. Solid metal gates a minimum of six (6) feet in height must be provided. iii. When possible, all service areas and mechanical equipment shall be located at the rear of the building and out of view of the roadways. 5 Tract C Retail District C.1 Except as noted below, the Tract C shall develop in accordance with the Retail District as it exists or may be amended. C.2 Uses. Uses shall be permitted in accordance with the Retail District with the exception of the following: Permitted with Specific Use Permit: 1. Convenience Store with Gas Pumps as an Accessory Use a. Accessory gas pumps are only allowed as an accessory use to a big box tenant and are subject to the following development standards i. Accessory gas pumps must be located on the same lot as a big box tenant ii. Convenience store with gas pumps is permitted only within two hundred and fifty (250) feet of the right-of-way line of Dallas Parkway iii. Accessory gas pumps shall be located at least two hundred and fifty (250) feet from a property line of a residential lot iv. Canopies shall have pitched roofs (min. roof pitch of 4:12) and the color and style of the metal roof on the gas station canopy shall be consistent with the metal roof on the big box building v. Canopy support columns shall be fully encased with masonry materials that are complimentary to that used on the main building vi. The canopy band face shall be a color consistent with the main structure and may not be backlit or used as signage vii. Use shall be removed if closed for more than six (6) months, including reclassification of fuel tanks per TCEQ Regulations viii. A raised landscape planter of the same material as the masonry columns shall be provided at both ends of all pump islands Prohibited Uses: 1. Athletic Stadium or Field, Private 2. Athletic Stadium or Field, Public 3. Cemetery/Mausoleum 4. Commercial Amusement, Outdoor 5. Recycling Collection Point 6. School District Bus Yard 7. Sewage Treatment Plant/Pumping Station 8. Trailer Rental 9. Utility Distribution/Transmission Facility 10. Water Treatment Plant C.3 Regulations 1. Outdoor sales and display shall be permitted with a Specific Use Permit but are limited to a big box use and subject to the following conditions: a. Shall be located within twenty five (25) feet of the front of the main building b. Shall not block or impair sidewalks, ADA access, doorways or fire lanes c. Shall not be displayed or stored on wooden crates, cardboard boxes, plastic cling wrap or in a fashion that resembles open storage of materials d. Permitted merchandise shall be seasonal and may include, but is not limited to: Christmas trees, flowers, landscaping materials, and outdoor furniture 2. Lot Coverage – Maximum of forty (40) percent a. Lot coverage is defined as the area covered by the building footprint 3. Drive-Thru Restaurants 6 a. Drive-Thru Restaurants may not be located on adjacent property and are limited to the following locations: i. No more than two (2) drive thru restaurants shall be permitted along the Dallas North Tollway/Dallas Parkway ii. No more than one (1) drive-thru restaurant shall be permitted along Prosper Trail b. No drive-thru restaurant shall be permitted any sooner than simultaneously with a certificate of occupancy that has been issued for the big box/anchor retail 4. Screening/Buffering a. A minimum of a twenty-five (25) foot landscape buffer is required along Prosper Trail and a minimum thirty (30) foot buffer is required along Dallas Parkway i. Planting Standards within Buffer 1. One (1) – Four (4) inch caliber evergreen tree shall be planted per thirty (30) linear feet of frontage. These trees may be planted in groups with appropriate spacing for species. 2. One (1) – Three (3) inch caliper ornamental tree shall be planted per thirty (30) linear feet of frontage. These trees may be planted in groups with appropriate spacing for species. 3. A minimum of fifteen (15) shrubs with a minimum size of five (5) gallons each shall be planted in the landscape area for every thirty (30) feet of frontage. Where parking spaces face the right-of-way, a second row of shrubs may be required in order to further screen the parking lot from view. 4. In addition to the tree and shrub requirements, berms must be provided within the landscape buffer. The berms must range in height from two (2) feet to four (4) feet. A minimum of fifty (50) percent of the berms must be four (4) feet in height. b. In addition to all screening requirements listed in Chapter 4, Section 5 of the Town of Prosper Zoning Ordinance, a minimum of a thirty (30) foot landscape buffer is required when the rear elevation and/or loading zone of any retail use backs a major or minor thoroughfare. This space shall be made up of a mixture of traditional landscape and four (4) foot landscaped berms in order to adequately screen the area. i. Planting Standards within Buffer a. One large evergreen tree, a minimum of four (4) inch caliper, must be planted for every 20 linear feet of street frontage. b. Ten (10) gallon shrubs shall be provided at a rate of 10 shrubs per 30 linear feet of street frontage ii. A minimum of twenty (20) feet of the landscape buffer shall be exclusive of all utility easements, right turn lanes, drainage easements, and right of ways. None of the required trees and/or shrubs shall be located within any utility easement. C.4 Additional Standards 1. Elevation Review and Approval a. All development within Tract C must submit a detailed material/style plan along with the façade plan/elevations in order to define the architectural character of the property. This must be submitted at the time of Preliminary Site Plan and/or Site Plan approval and is subject to approval by the Town of Prosper Planning & Zoning Commission and Town Council. b. The design of any major tenant and/or attached retail component shall reflect the general concept developed in the conceptual elevations (Exhibit D). Changes to materials and architectural elements is permitted so long as the original character is maintained and all design guidelines specified within this document are adhered too. 2. Open Space/Detention 7 a. Within the Retail District, a minimum of six (6) acres of open space is required. This space may include detention and floodplain areas and will contain landscaping and amenities where applicable. i. An eight (8) foot wide hike and bike trail connecting to the overall trail plan will be located with this area ii. Planting standards a. One (1) – Four (4) inch caliper evergreen tree shall be planted per thirty (30) feet of linear frontage. These trees may be planted in groups with appropriate spacing for species. b. One (1) – Three (3) inch caliper ornamental tree shall be planted per thirty (30) linear feet of frontage. These trees may be planted in groups with appropriate spacing for species. c. A minimum of fifteen shrubs with a minimum size of five (5) gallons each shall be planted in the landscape area for every thirty (30) feet of frontage d. It is intended that all plant types promote a natural landscape. Where possible, the planting shall be in accordance with the general planting style as shown in Exhibit F-1. b. Detention/Retention a. Detention located within the Floodplain must meet all Town of Prosper, FEMA and all other applicable regulations C.5 Design Guidelines 1. Architectural standards a. Buildings must be one hundred percent (100%) masonry, excluding windows, doors, trim and accent materials i. Masonry materials include brick, stone, and/or stucco ii. The primary material shall be brick and/or stone. Stucco may be used as an accent not to exceed 20% of any exterior elevation. b. The style of all buildings must be consistent and in keeping with the style of the entire Planned Development as shown on the conceptual elevations (Exhibit G) c. All materials and exterior colors shall be compatible with those used throughout the development as well as any similar developments adjacent to the Planned Development d. Building articulation is required on all elevations. This may be achieved through recessed or projecting architectural elements, variation in roof line, etc. e. No single finish shall cover more than eighty (80) percent of the front of any building. f. Pitched Roofs are required for all Pad Sites in Tract C i. Buildings less than 5,000 sq. ft. shall have a minimum roof pitch of 8:12 ii. Buildings less than 10,000 sq. ft. shall have a minimum roof pitch of 6:12 iii. Any building 10,000 sq.ft. or larger must have a minimum roof pitch of 4:12 2. Screening a. Service, Mechanical and Utility Equipment i. All service, mechanical and/or utility equipment shall be completely screened from public view by architectural screens, fences and/or landscaping ii. Trash cans and dumpster locations shall be permanently fenced or screened with enclosures rendering these functions hidden from public view. These enclosures shall be reinforced masonry and must match the materials used on the primary structure. Solid metal gates a minimum of six (6) feet in height must be provided. iii. When possible, all service areas and mechanical equipment shall be located at the rear of the building and out of view of the roadways ã RISLAND PROSPER 221 LLCRISLAND PROSPER 221 LLCPD-75-OFFICEPD-75-SF 15PD-75-OFFICEPD-75-RETAIL PROSPER TRAILSHAWNEE TRAIL ã -Exhibit E- Development Schedule The phasing and development of this project is dependent upon market conditions and the construction of the Dallas North Tollway and Prosper Trail. Upon initiation of development, the project is expected to be completed in three (3) to four (4) phases, lasting approximately 12-36 months for each phase. RESULTS Page 1 of 3 ] Prosper is a place where everyone matters. AGENDA BRIEFING – EXECUTIVE CONFERENCE ROOM 1. Call to Order/Roll Call. 2. Questions about items listed on the Regular Meeting Agenda. 3. Discussion Items:  Downtown Festival Update (DR)  Mobile Food Truck Park Policy (DR) THE REGULAR TOWN COUNCIL MEETING CONVENES IN COUNCIL CHAMBERS IMMEDIATELY FOLLOWING THE AGENDA BRIEFING 1. Call to Order/Roll Call. 2. Invocation, Pledge of Allegiance and Pledge to the Texas Flag. 3. Announcements of recent and upcoming events. 4. CONSENT AGENDA: All Consent Agenda Items Approved, 7-0 with exceptions noted below (Items placed on the Consent Agenda are considered routine in nature and non- controversial. The Consent Agenda can be acted upon in one motion. Items may be removed from the Consent Agenda by the request of Council Members or staff.) 4a. Consider and act upon minutes from the following Town Council meeting. (RB)  Regular Meeting – January 22, 2019  Special Meeting – January 30, 2019 4b. Consider and act upon an ordinance ordering a General Election to be held on May 4, 2019, and authorizing the Town Manager to execute contracts with the Collin County Election Administration, the Denton County Election Administration, and the Prosper Independent School District for joint election services. (RB) 4c. Conduct a Public Hearing, and consider and act upon a request for a Specific Use Permit for a Wireless Communication and Support Structure, on 0.5± acre, located in Frontier Park, on the south side of Frontier Parkway, south and west of Stadium Drive. (S18-0007). (AG) Tabled to April 23, 2019 per request of the applicant AGENDA Agenda Briefing and Regular Meeting of the Prosper Town Council Prosper Town Hall 200 S. Main Street, Prosper, Texas Tuesday, February 12, 2019 5:45 p.m. RESULTS Page 2 of 3 4d. Consider and act upon authorizing the Town Manager to execute a Tower Site Lease Agreement by and between the Town of Prosper, Texas, and New Cingular Wireless PCS, LLC, for the lease of Town property, generally located at 1551 Frontier Parkway in Frontier Park, for a cell tower. (CS) Tabled to April 23, 2019 4e. Consider and act upon authorizing the Town Manager to execute a Development Agreement between the Town of Prosper, Texas, and Lakes of Legacy LLC., related to early issuance of building permits for the Lakes of Legacy, Phase 1 development. (DH) 4f. Consider and act upon whether to direct staff to submit a written notice of appeal on behalf of the Town Council to the Development Services Department, pursuant to Chapter 4, Section 1.5(C)(7) and 1.6(B)(7) of the Town’s Zoning Ordinance, regarding action taken by the Planning & Zoning Commission on any Site Plan or Preliminary Site Plan. (AG) 5. CITIZEN COMMENTS: The public is invited to address the Council on any topic. However, the Council is unable to discuss or take action on any topic not listed on this agenda. Please complete a “Public Meeting Appearance Card” and present it to the Town Secretary prior to the meeting. REGULAR AGENDA: If you wish to address the Council during the regular agenda portion of the meeting, please fill out a “Public Meeting Appearance Card” and present it to the Town Secretary prior to the meeting. Citizens wishing to address the Council for items listed as public hearings will be recognized by the Mayor. Those wishing to speak on a non-public hearing related item will be recognized on a case-by-case basis, at the discretion of the Mayor and Town Council. ITEMS FOR INDIVIDUAL CONSIDERATION: 6. Conduct a Public Hearing, and consider and act upon an ordinance rezoning a portion of Planned Development-3-Single Family (PD-3-SF) to Planned Development-Office (PD- O), on 12.9± acres, located south of Prosper Trail, west of Cook Lane, to a llow for the development of a Town Public Safety Facility. (Z18-0018). (AG) Approved, 7-0 7. Discussion on Public Safety Complex Phase 1 (Police Station and Dispatch) Facility. (DK) 8. Consider and act upon a request for a Subdivision Waiver for lots without road frontage for Prosper Commons, Block B, Lots 11 and 12, on 4.6± acres, located on the west side of Coit Road, north of US 380. The property is zoned Planned Development-2 (PD-2). (D18-0122). (AG) Approved, 7-0 9. EXECUTIVE SESSION: Recess into Closed Session in compliance with Section 551.001 et seq. Texas Government Code, as authorized by the Texas Open Meetings Act, to deliberate regarding: 9a. Section 551.087 – To discuss and consider economic development incentives. RESULTS Page 3 of 3 9b. Section 551.072 – To discuss and consider purchase, exchange, lease or value of real property for municipal purposes and all matters incident and related thereto. 9c. Section 551.074 – To discuss and review the Town Manager’s performance evaluation. 10. Reconvene in Regular Session and take any action necessary as a result of the Closed Session. 11. Possibly direct Town staff to schedule topic(s) for discussion at a future meeting. 12. Adjourn. CERTIFICATION I, the undersigned authority, do hereby certify that this Notice of Meeting was posted at Prosper Town Hall, located at 200 S. Main Street, Prosper, Texas 75078, a place convenient and readily accessible to the general public at all times, and said Notice was posted by 5:00 p.m., on Friday, February 8, 2019, and remained so posted at least 72 hours before said meeting was convened. _______________________________ _________________________ Robyn Battle, Town Secretary Date Notice Removed Pursuant to Section 551.071 of the Texas Government Code, the Town Council reserves the right to consult in closed session with its attorney and to receive legal advice regarding any item listed on this agenda. NOTICE Pursuant to Town of Prosper Ordinance No. 13-63, all speakers other than Town of Prosper staff are limited to three (3) minutes per person, per item, which may be extended for an additional two (2) minutes with approval of a majority vote of the Town Council. NOTICE OF ASSISTANCE AT PUBLIC MEETINGS: The Prosper Town Council meetings are wheelchair accessible. For special services or assistance, please contact the Town Secretary’s Office at (972) 569 - 1011 at least 48 hours prior to the meeting time.