Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
01.07.20 PZ Packet
] 1. Call to Order / Roll Call 2. Pledge of Allegiance. 3. CONSENT AGENDA (Items placed on the Consent Agenda are considered routine in nature and are considered non-controversial. The Consent Agenda can be acted upon in one motion. A Planning & Zoning Commissioner may remove any item for discussion and separate action. Planning & Zoning Commissioners may vote nay on any single item without comment and may submit written comments as part of the official record.) 3a. Consider and act upon minutes from the December 3, 2019, Planning & Zoning Commission Regular meeting. 3b. Consider and act upon a Site Plan for a multi-tenant retail/restaurant building, on 1.9± acres, located on the southeast corner of Prosper Trail and Coit Road. The property is zoned Planned Development-5 (PD-5). (D19-0105). 3c. Consider and act upon a Replat for Whispering Farms Commercial Center, Block A, Lot 4R-C1, on 1.9± acres, located on the southeast corner of Prosper Trail and Coit Road. The property is zoned Planned Development-5 (PD-5). (D19-0106). REGULAR AGENDA If you wish to address the Planning & Zoning Commission, please fill out a “Public Meeting Appearance Card” and present it to the Chair, preferably before the meeting begins. Pursuant to Section 551.007 of the Texas Government Code, individuals wishing to address the Planning & Zoning Commission for items listed as public hearings will be recognized when the public hearing is opened. For individuals wishing to speak on a non-public hearing item, they may address the Commission when the item is considered by the Planning & Zoning Commission. 4. Conduct a Public Hearing, and consider and act upon a request to amend Planned Development-91 (PD-91), for Cook Children’s North Campus, on 23.7± acres, located on the northeast corner of US 380 and Windsong Parkway, to modify the concept plans to accommodate an increased hospital size and modified parking. (Z19-0021). 5. Conduct a Public Hearing, and consider and act upon a request to rezone 0.6± acres from Single Family-15 (SF-15) to Downtown Single Family (DTSF), located on the south side of Third Street, east of Coleman Street. (Z19-0022). 6. Conduct a Public Hearing, and consider and act upon a request to rezone 2.1± acres from Single Family-15 (SF-15) to Planned Development-Downtown Office (PD-DTO), located on the north side of Broadway Street, west of Craig Road. (Z19-0023). 7. Review actions taken by the Town Council and possibly direct Town Staff to schedule topic(s) for discussion at a future meeting. 8. Adjourn. AGENDA Regular Meeting of the Prosper Planning & Zoning Commission Prosper Town Hall Council Chambers 250 W. First Street, Prosper, Texas Tuesday, January 7, 2020, 6:00 p.m. Prosper is a place where everyone matters. Note: The order in which items are heard on the agenda is subject to change. CERTIFICATION I, the undersigned authority, do hereby certify that this Notice of Meeting was posted at Prosper Town Hall, located at 250 W. First Street, Prosper, Texas 75078, a place convenient and readily accessible to the general public at all times, and said Notice was posted by 5:00 p.m., on Friday, January 3, 2020, and remained so posted at least 72 hours before said meeting was convened. _______________________________ _________________________ Melissa Lee, Deputy Town Secretary Date Notice Removed Pursuant to Section 551.071 of the Texas Government Code, the Town Council reserves the right to consult in closed session with its attorney and to receive legal advice regarding any item listed on this agenda. NOTICE Pursuant to Town of Prosper Ordinance No. 13-63, all speakers other than Town of Prosper staff are limited to three (3) minutes per person, per item, which may be extended for an additional two (2) minutes with approval of a majority vote of the Town Council. NOTICE OF ASSISTANCE AT PUBLIC MEETINGS: The Prosper Town Hall is wheelchair accessible. For special services or assistance, please contact the Town Secretary’s Office at (972) 569-1011 at least 48 hours prior to the meeting time. Page 1 ] 1. Call to Order / Roll Call The meeting was called to order at 6:00 p.m. Commissioners present: Chairman Charles Cotten, Vice-Chairman Brandon Daniel, Secretary Amy Bartley, Chris Kern, Chris Long, and Sarah Peterson. Commissioners absent: Joe Grinstead Staff present: Alex Glushko, Planning Manager; Scott Ingalls, Senior Planner; and Evelyn Mendez, Planning Technician. 2. Recitation of the Pledge of Allegiance. 3. CONSENT AGENDA 3a. Consider and act upon minutes from the November 5, 2019, Planning & Zoning Commission Regular meeting. 3b. Consider and act upon a Preliminary Site Plan for one (1) retail building, three (3) medical office buildings, and one (1) day care (Pinnacle Montessori), in Prosper Crossing, on 5.9± acres, located on the south side of Richland Boulevard, east of Coit Road. This property is zoned Planned Development-38 (PD-38) and Specific Use Permit (S-20). (D17-0052). 3c. Consider and act upon a Site Plan for a day care (Pinnacle Montessori) in Prosper Crossing, on 2.5± acres, located on the south side of future Richland Boulevard, east of Coit Road. The property is zoned Planned Development-38 (PD-38) and Specific Use Permit-20 (S-20). (D17-0073). 3d. Consider and act upon a Preliminary Site Plan for Victory at Frontier, on 28.2± acres, located on the southwest corner of Frontier Parkway and Preston Road. The property is zoned Planned Development-10 (PD-10). (D19-0102). 3e. Consider and act upon a Replat of Silo Park Addition, Block A, Lots 1R & 2, on 2.2± acres, located on the northeast corner of Broadway Street and McKinley Street. The property is zoned Planned Development-84 (PD-84). (D19-0107). 3f. Consider and act upon a Site Plan for a Drive-Through Restaurant (Starbucks) in Gates of Prosper, on 1.2± acres, located on the west side of Preston Road, south of Lovers Lane. The property is zoned Planned Development-67 (PD-67). (D19-0108). 3g. Consider and act upon a Final Plat for Gates of Pro sper, Phase 2, Block A, Lots 1- 14, on 52.1± acres, located on the southwest corner of Preston Road and Lovers Lane. The property is zoned Planned Development-67 (PD-67). (D19-0109). MINUTES Regular Meeting of the Prosper Planning & Zoning Commission Prosper Town Hall Council Chambers 250 W. First Street, Prosper, Texas Tuesday, December 3, 2019, 6:00 p.m. Prosper is a place where everyone matters. Page 2 3h. Consider and act upon a Site Plan for a multi-tenant office/retail building (Ebby Halliday), on 1.4± acres, located on the east side of Preston Road, north of Prosper Trail. The property is zoned Planned Development-68 (PD-68). (D19-0110). 3i. Consider and act upon a Replat for Shops at Prosper Trail, Block A, Lots 7 & 8, on 2.3± acres, located on the east side of Preston Road, north of Prosper Trail. The property is zoned Planned Development-68 (PD-68). (D19-0111). 3j. Consider and act upon a Site Plan for 380 Professional Park, on 9.3± acres, located on the south side of Richland Boulevard, west of Coit Road. The property is zoned Planned Development-2 (PD-2). (D19-0112). 3k. Consider and act upon a Final Plat for Prosper Commons, Block B, Lot 1, on 9.3± acres, located on the south side of Richland Boulevard, west of Coit Road. The property is zoned Planned Development-2 (PD-2). (D19-0113). Motion by Daniel, second by Long, to approve the Consent Agenda, subject to staff recommendations. Motion approved 6 -0. REGULAR AGENDA 4. Consider and act upon a Preliminary Site Plan for a House of Worship (Rhea’s Mill Baptist Church), on 9.3± acres, located on the west side of Custer Road, south of Frontier Parkway. The property is zoned Agricultural (A). (D19 -0101). Mendez: Summarized the request, including a solid living screen in lieu of a masonry wall, presented exhibits provided by the applicant , and recommended approval. Jared Maier (Applicant): Provided information regarding the proposed request. Commissioners voiced support for the request. Motion by Peterson, second by Long, to approve Item 4, subject to staff recommendations. Motion approved 6-0. 5. Consider and act upon a request to update the Planned Development-40 (PD-40) Conceptual Elevations for the Windsong Ranch Townhomes, on 21.4± acres, located on the west side of Teel Parkway, south of Fishtrap Road. (Z18 -0017). Glushko: Summarized the request, presented exhibits provided by the applicant , and recommended approval. Robert Swegler (Applicant): Provided information regarding the request. Commissioners voiced support for the request. Motion by Peterson, second by Daniel, to approve Item 5. Motion approve 6-0. 6. Conduct a Public Hearing, and consider and act upon a request to amend Planned Development-91 (PD-91), for Cook Children’s North Campus, on 23.7± acres, to modify the concept plans to accommodate an increased hospital size and modified parking. (Z19-0021). Page 3 Glushko: Noted the applicant’s request to table the item. Motion by Daniel, second by Bartley, to table Item 6 and continue the Public Hearing to the January 7, 2020, Planning & Zoning Commission meeting . Motion approved 6-0. 7. Review actions taken by the Town Council and possibly direct Town Staff to schedule topic(s) for discussion at a future meeting. Glushko: Provided a summary of recent action taken by Town Council. 8. Adjourn. Motion by Long, second by Peterson, to adjourn. Motion approved 6-0 at 6:20 p.m. ___________________________________ ______________________________________ Evelyn Mendez, Planning Technician Amy Bartley, Secretary Page 1 of 1 To: Planning & Zoning Commission Item No. 3b From: Scott Ingalls, AICP, Senior Planner Through: Alex Glushko, AICP, Planning Manager Re: Planning & Zoning Commission Meeting – January 7, 2020 Agenda Item: Consider and act upon a Site Plan for a multi-tenant retail/restaurant building, on 1.9± acres, located on the southeast corner of Prosper Trail and Coit Road. The property is zoned Planned Development-5 (PD-5). (D19-0105). Description of Agenda Item: The Site Plan shows the proposed 10,500 square-foot multi-tenant retail/restaurant building. Access is provided from Prosper Trail and Coit Road. The depicted number of off-street parking spaces meets the minimum standards of the Zoning Ordinance . The Site Plan conforms to the PD-5 development standards. As a companion item, the Replat for Whispering Farms Commercial Center, Block A, Lot 4R-C1 (D19-0106) is on the January 7, 2020 agenda. Attached Documents: 1. Location Map 2. Site Plan Staff Recommendation: Staff recommends approval of the Site Plan subject to: 1. Town staff approval of civil engineering, landscape, irrigation plans, open space plans, and façade elevations. 2. Town staff approval of all fire hydrants, fire department connection (FDC) and fire lanes, including widths, radii, and location. Prosper is a place where everyone matters. PLANNING D19-0105 COIT RDPROSPER TRL GLEN HAVEN CT WESTVIEW CTWIND BROOK LNLASSEN DR CRIPPLE CREEK DR ±0 150 30075Feet GAS GAS 20' ACCESS EASEMENT DOC. NO. 20070906001247510 O.P.R.C.C.T. 24' FIRE LANE, ACCESS & UTILITY EASEMENT DOC. NO. 2006-89 P.R.C.C.T. 24' FIRE LANE, ACCESS & UTILITY EASEMENT DOC. NO. 2006-89 P.R.C.C.T.24' FIRE LANE, ACCESS &UTILITY EASEMENTDOC. NO. 2006-89P.R.C.C.T.24' FIRE LANE, ACCESS,UTILITY & DRAINAGE EASEMENTDOC. NO. 2008-529P.R.C.C.T.24' FIRE LANE, ACCESS,UTILITY & DRAINAGE EASEMENTDOC. NO. 2008-529P.R.C.C.T.24' ACCESS EASEMENTDOC. NO. 2008-529P.R.C.C.T.10' PRIVATE DRAINAGE EASEMENT DOC. NO. 2008-529 P.R.C.C.T. 12' UTILITY EASEMENT DOC. NO. 2006-89 P.R.C.C.T. 12' UTILITY EASEMENT DOC. NO. 2006-89 P.R.C.C.T. 15' LANDSCAPE EASEMENT DOC. NO. 2006-89 P.R.C.C.T. 15' PEDESTRIAN ACCESS EASEMENT DOC. NO. 2006-89 P.R.C.C.T. LOT 3-C, BLOCK A WHISPERING FARMS COMMERCIAL CENTER DOC. NO. 2006-89 P.R.C.C.T. LOT 4R-C, BLOCK A WHISPERING FARMS COMMERCIAL CENTER DOC. NO. 2008-529 P.R.C.C.T.COIT ROADVARIABLE WIDTH RIGHT-OF-WAYLOT 2R-C, BLOCK A WHISPERING FARMS COMMERCIAL CENTER DOC. NO. 2006-89 P.R.C.C.T. PROSPER TRAIL VARIABLE WIDTH RIGHT-OF-WAY 84,805 SQ.FT. 1.947 ACRES LOT 4-D BLOCK A WHISPERING FARMS COMMERCIAL CENTER DOC. NO. 2008-529 P.R.C.C.T. 10' SIDEWALK EASEMENT VOL. 2008, PG. 529 P.R.C.C.T. 10' SIDEWALK EASEMENT VOL. 2008, PG. 529 P.R.C.C.T. PRIVATE FIRE LINE EASEMENT VOL. 2008, PG. 529 P.R.C.C.T. 12' UTILITY EASEMENT VOL. 2006, PG. 89 D.R.C.C.T. ACCESS AND DRAINAGE EASEMENT VOL. 2008, PG. 529 P.R.C.C.T. BUILDING 10,500 SF ZONED- PD-5 COMMERCIAL EXISTING BLDG ZONED- PD-5 COMMERCIAL LOT 2-X BLOCK D WHISPERING FARMS PHASE 1 ZONED: SF VACANT 1 2 PROP 15' WATER ESMT 24'PROP 24' ACCESS ESMT18'18'9'R30'R30 ' 18'9'R20'EX1 8 '9'18'9'18'9' 5' 5'18'9'PROP FDC EX FIRE HYDRANT 13'15' EX FIRE HYDRANT ADA RAMP ADA RAMP ADA RAMP FLUSH CURB EX WYE INLET PROP 5' CURB INLET PROP 10' CURB INLET RETAINING WALL WITH 42" HANDRAIL MAX HEIGHT 7'30' BLDG SETBACK25' LANDSCAPEAND HIKE & BIKE TRAILEASEMENT30' BLDG SETBACK 25' LANDSCAPE AND HIKE & BIKE TRAIL EASEMENT 10' BLDG SETBACK10' BLDG SETBACK PROP FIRE HYDRANT R 3 'R3'EX CURB INLET 50'R20.1'EX145.73'125.01'325' ± TO NEXTDRIVEWAYR30' R 1 0 ' R 1 0 'R10'R8'R10'R10 'R20'10'18'9'18'9'24' 9' 2' 2'9'18' 1 1 '10'1 0 ' 5.5' 9'R20'R44' R44'R20' R44' R20'5.5'10' 10' R2 0 . 6 ' EX . 1 8 '9'10'24' FIRE LANE, ACCESS, DRAINGE AND UTILITY EASEMENT 5' LANDSCAPE SETBACK5' LANDSCAPE SETBACK RETAINING WALL WITH 42" HANDRAIL MAX HEIGHT 7' EX FIRE HYDRANT PROP FIRE HYDRANT ABANDON FL AND ACCESS ESMT. RETAIN DRAINAGE AND UTILITY ESMT FLUSH CURB BOLLARD TYP DUMPSTER ENCLOSURE 9'18'5.5'R3 0 ' R54' R40'R3 0 ' R 5 4 'R54' 2 4 ' 2' DELIVERY RAMP PROPOSED STAIRS PROPOSED STAIRSR8' R10'6'5' 5'DATENo.REVISIONBYDATE: SHEET File No. 12/13/2019 CHECKED:ASD DRAWN:LRR DESIGN:LRRRETAIL BUILDINGCOIT RD AND PROSPER TRPROSPER, TX1105 CHEEK SPARGER RD. SUITE #1PHONE: 817.281.0572COLLEYVILLE, TX 76034 WWW.CLAYMOOREENG.COMPRELIMINARY CLAYMOORE ENGINEERING TEXAS REGISTRATION #14199 2019-150 0 GRAPHIC SCALE 1 inch = ft. 30 30 60 30 15 TOWN OF PROSPER SITE PLAN GENERAL NOTES: 1. DUMPSTERS AND TRASH COMPACTORS SHALL BE SCREENED IN ACCORDANCE WITH THE ZONING ORDINANCE. 2. OPEN STORAGE, WHERE PERMITTED, SHALL BE SCREENED IN ACCORDANCE WITH THE ZONING ORDINANCE. 3. OUTDOOR LIGHTING SHALL COMPLY WITH THE LIGHTING AND GLARE STANDARDS CONTAINED WITHIN THE ZONING ORDINANCE AND SUBDIVISION ORDINANCE. 4. LANDSCAPING SHALL CONFORM TO LANDSCAPE PLANS APPROVED BY THE TOWN. 5. ALL ELEVATIONS SHALL COMPLY WITH THE STANDARDS CONTAINED WITHIN THE ZONING ORDINANCE. 6. BUILDINGS OF 5,000 SQUARE FEET OR GREATER SHALL BE 100% FIRE SPRINKLED. ALTERNATIVE FIRE PROTECTION MEASURES MAY BE APPROVED BY THE FIRE DEPARTMENT. 7. FIRE LANES SHALL BE DESIGNED AND CONSTRUCTED PER TOWN STANDARDS OR AS DIRECTED BY THE FIRE DEPARTMENT. 8. TWO POINTS OF ACCESS SHALL BE MAINTAINED FOR THE PROPERTY AT ALL TIMES. 9. SPEED BUMPS/HUMPS ARE NOT PERMITTED WITHIN A FIRE LANE. 10. HANDICAPPED PARKING AREAS AND BUILDING ACCESSIBILITY SHALL CONFORM TO THE AMERICANS WITH DISABILITIES ACT (ADA) AND WITH THE REQUIREMENTS OF THE CURRENT, ADOPTED BUILDING CODE. 11. ALL SIGNAGE IS SUBJECT TO BUILDING OFFICIAL APPROVAL. 12. ALL FENCES AND RETAINING WALLS SHALL BE SHOWN ON THE SITE PLAN AND ARE SUBJECT TO BUILDING OFFICIAL APPROVAL. 13. ALL EXTERIOR BUILDING MATERIALS ARE SUBJECT TO BUILDING OFFICIAL APPROVAL AND SHALL CONFORM TO THE APPROVED FAÇADE PLAN. 14. SIDEWALKS OF NOT LESS THAN SIX (6’) FEET IN WIDTH ALONG THOROUGHFARES AND COLLECTORS AND FIVE (5’) IN WIDTH ALONG RESIDENTIAL STREETS, AND BARRIER FREE RAMPS AT ALL CURB CROSSINGS SHALL BE PROVIDED PER TOWN STANDARDS. 15. APPROVAL OF THE SITE PLAN IS NOT FINAL UNTIL ALL ENGINEERING PLANS ARE APPROVED BY THE ENGINEERING DEPARTMENT. 16. SITE PLAN APPROVAL IS REQUIRED PRIOR TO GRADING RELEASE. 17. ALL NEW ELECTRICAL LINES SHALL BE INSTALLED AND/OR RELOCATED UNDERGROUND. 18. ALL MECHANICAL EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW IN ACCORDANCE WITH THE ZONING ORDINANCE. 19. ALL LANDSCAPE EASEMENTS MUST BE EXCLUSIVE OF ANY OTHER TYPE OF EASEMENT. 20. IMPACT FEES WILL BE ASSESSED IN ACCORDANCE WITH THE LAND USE CLASSIFICATION(S) IDENTIFIED ON THE SITE DATA SUMMARY TABLE; HOWEVER, CHANGES TO THE PROPOSED LAND USE AT THE TIME CO AND/OR FINISH-OUT PERMIT MAY RESULT IN ADDITIONAL IMPACT FEES AND/OR PARKING REQUIREMENTS. 21. ALL DIMENSIONS ARE TO FACE OF CURB UNLESS OTHERWISE NOTED. 22. THE APPROVAL OF A SITE PLAN SHALL BE EFFECTIVE FOR A PERIOD OF EIGHTEEN (18) MONTHS FROM THE DATE OF APPROVAL BY THE PLANNING & ZONING COMMISSION, AT THE END OF WHICH TIME THE APPLICANT MUST HAVE SUBMITTED AND RECEIVED APPROVAL OF ENGINEERING PLANS AND BUILDING PERMITS. IF THE ENGINEERING PLANS AND BUILDING PERMITS ARE NOT APPROVED, THE SITE PLAN APPROVAL, TOGETHER WITH ANY PRELIMINARY SITE PLAN FOR THE PROPERTY, IS NULL AND VOID. COUNTY SURVEY:ABSTRACT NO. COLLIN CITY:STATE: PROSPER TEXAS LEGAL DESCRIPTION: APPLICANT: CLAYMOORE ENGINEERING, INC. 1903 CENTRAL DRIVE, SUITE #406 BEDFORD, TX 76021 PH: 817.281.0572 SURVEYOR: WINDROSE SURVEYING 220 ELM STREET, SUITE 200 LEWISVILLE, TX 75057 PH: 972.370.5834 CONTACT NAME: MATT MOORE CONTACT NAME: EDDIE RODRIGUEZ LOT 4R-C, BLOCK A WHISPERING FARMS COMMERCIAL CENTER. CAT RETAIL BUILDING SITE PLAN CASE #: D19-0105 DEVELOPER: MAT MANAGEMENT SERVICES, LTD 14114 DALLAS PARKWAY SUITE #670 DALLAS, TX 75254 PH: 214.483.0400 CONTACT NAME: CARY ALBERT WATER METER SCHEDULE ID TYPE SIZE NO. DOM. 2" 1 IRR. 2" 1 1 2 W.H. THOMASON 895 ACCORDING TO MAP NO. 48085C0235J, DATED JUNE 2, 2009 OF THE NATIONAL FLOOD INSURANCE PROGRAM MAP, FLOOD INSURANCE RATE MAP OF COLLIN COUNTY, TEXAS, FEDERAL EMERGENCY MANAGEMENT AGENCY, FEDERAL INSURANCE ADMINISTRATION, THIS PROPERTY IS WITHIN ZONE "X", (AREAS DETERMINED TO BE OUTSIDE OF THE 0.2% ANNUAL CHANCE FLOODPLAIN). IF THIS SITE IS NOT WITHIN AN IDENTIFIED SPECIAL FLOOD HAZARD AREA, THIS FLOOD STATEMENT DOES NOT IMPLY THAT THE PROPERTY AND/OR THE STRUCTURES THEREON WILL BE FREE FROM FLOODING OR FLOOD DAMAGE. ON RARE OCCASIONS, GREATER FLOODS CAN AND WILL OCCUR AND FLOOD HEIGHTS MAY BE INCREASED BY MAN-MADE OR NATURAL CAUSES. THIS FLOOD STATEMENT SHALL NOT CREATE LIABILITY ON THE PART OF THE SURVEYOR. FLOODPLAIN NOTE SITE PLANSP-1 BENCHMARK #1: "X" CUT SET ON EXISTING CURB INLET IN PROSPER TRAIL. APPROXIMATELY 145' EAST OF COIT RD. ELEVATION: 756.00 FT BENCHMARK #2: "X" CUT SET ON EXISTING STORM DRAIN MANHOLE. APPROXIMATELY 30' WEST OF SE PROPERTY CORNER. ELEVATION: 745.70 FT LEGEND LIGHT DUTY CONCRETE PAVEMENT MEDIUM DUTY CONCRETE PAVEMENT MEDIUM DUTY CONCRETE PAVEMENT DUMPSTER AREA CONCRETE PAVEMENT CONCRETE PER TOWN OF PROSPER STANDARDS EXISTING CONCRETE PAVING TO REMAIN PROPOSED CONCRETE SIDEWALK PROPOSED PUBLIC SIDEWALK PER TOWN STANDARDS PROPOSED CONCRETE CURB AND GUTTER PARKING COUNT PROPOSED FIRE LANE STRIPPING SITE DATA SUMMARY LOT ZONING PROPOSED USE LOT SIZE (ACRES)LOT SIZE (SQ. FT.)BLDG. AREA (SQ. FT.) BLDG HGT. (FT) LOT COVERAGE FLOOR AREARATIO PARKING HANDICAP SP.TOTAL IMPERVIOUS (SQ FT) LANDSCAPING OPEN SPACE REQ.PROV.REQ.PROV.REQ. RATIO REQ.PROV.REQ.PROV.REQ. (15 SF PER PARKING SPACE)PROV.REQ. (7% NET SITE AREA), SQ FT PROV. 4R-C CPD-5 MIXED USERESTAURANT 6,000 SFRETAIL 4,500 SF 1.95 84,805 10,500 1 STORY20 FT 40% MAX 12.4%0.4:1MAX 0.12 1 SPACE / 250 SF RETAIL 1 SPACE/ 100 SF RESTAURANT 78 78 4 4 54,820 65%1,170 1,351 5,936 6,832 Page 1 of 1 To: Planning & Zoning Commission Item No. 3c From: Scott Ingalls, AICP, Senior Planner Through: Alex Glushko, AICP, Planning Manager Re: Planning & Zoning Commission Meeting – January 7, 2020 Agenda Item: Consider and act upon a Replat for Whispering Farms Commercial Center, Block A, Lot 4R-C1, on 1.9± acres, located on the southeast corner of Prosper Trail and Coit Road. The property is zoned Planned Development-5 (PD-5). (D19-0106). Description of Agenda Item: The Replat dedicates all easements necessary for development and conforms to the PD-5 development standards. As a companion item, the Site Plan for a multi-tenant retail/restaurant building (D19-0105) is on the January 7, 2020 agenda. Attached Documents: 1. Location Map 2. Replat Staff Recommendation: Staff recommends approval of the Replat subject to: 1. To staff approval of all additions and/or alterations to the easements and dedications on the Replat. Prosper is a place where everyone matters. PLANNING D19-0106 COIT RDPROSPER TRL GLEN HAVEN CT WESTVIEW CTWIND BROOK LNLASSEN DR CRIPPLE CREEK DR ±0 150 30075Feet LOT 3-C, BLOCK A WHISPERING FARMS COMMERCIAL CENTER DOC. NO. 2006-89 P.R.C.C.T.COIT ROADVARIABLE WIDTH RIGHT-OF-WAYLOT 2R-C, BLOCK A WHISPERING FARMS COMMERCIAL CENTER DOC. NO. 2006-89 P.R.C.C.T. PROSPER TRAIL VARIABLE WIDTH RIGHT-OF-WAY 84,805 SQ.FT. 1.947 ACRES LOT 4-D BLOCK A WHISPERING FARMS COMMERCIAL CENTER DOC. NO. 2008-529 P.R.C.C.T.N03°26'16"E 48.83'S89°50'59"W 297.76'N03°26'16"E 101.17'N00°10'05"W 165.00'N44°51'46"E 35.31 ' N89°56'07"E 175.00'N86°06'46"E 90.21'S00°26'14"E 296.56'35' PUBLIC TRAIL LOT 2X, BLOCK A CAB. Q, PG. 176 P.R.C.C.T. LOT 4R-C1, BLOCK A POINT OF BEGINNING D REPLAT WHISPERING FARMS COMMERCIAL CENTER LOT 4R-C1, BLOCK A Being a 1.947 Acre Replat of Lot 4R-C, Block A Whispering Farms Commercial Center Doc. No. 2008-529, P.R.C.C.T. Town of Prosper, Collin County, Texas -- 2019 -- OWNER/DEVELOPER Dermatology Assets of Prosper, LLC 6100 Windhaven Parkway Plano, Texas 75093-8046 SURVEYOR'S NOTES: 1.Bearings and distances are based on Texas State Plane Coordinate System, Texas North Central Zone 4202 North American Datum of 1983 (NAD 83) (U.S. Foot) with a combined scale factor of 1.000152710. 2.This property lies within Zone "X" Unshaded of the Flood Insurance Rate Map for Collin County, Texas and Incorporated Areas, map no. 48085C0235J, dated June 2, 2009, via scaled map location and graphic plotting. 3.Notice: Selling a portion of this addition by metes and bounds is a violation of City subdivision ordinance and state platting statutes and is subject to fines and withholding of utilities and building certificates. 4.The purpose of this plat is to add and subtract easements. STATE OF TEXAS COUNTY OF COLLIN WHEREAS Dermatology Assets of Prosper, LLC are the owners of a 1.947 acre tract of land situated in the W.H. Thomason Survey, Abstract Number 895, being all of Lot 4R-C, Block A, Whispering Farms Commercial Center, an addition to the Town of Prosper, as recorded in Document Number 2008-529, Plat Records, Collin County, Texas, also being conveyed to Dermatology Assets of Prosper, LLC by deed recorded in Instrument Number 20110902000937220, Deed Records, Collin County, Texas and being more particularly described by metes and bounds as follows: BEGINNING at a 1/2 inch rebar capped "SPIRARS ENGR" found for the northwest corner of Lot 4-D, Block A of said Whispering Farms Commercial Center, also lying on the east right of way line of County Road No. 80 (Coit Road) (Variable Width Right of Way); THENCE North 03 degrees 26 minutes 16 seconds East, with the east right of way line of said County Road No. 80, a distance of 101.17 feet to a 1/2 inch rebar capped "JBI" found for corner; THENCE North 00 degrees 10 minutes 05 seconds West, with the east right of way line of said County Road No. 80, a distance of 165.00 feet to a 1/2 inch rebar capped "ASC" set for corner and lying at the intersection of the east right of way line of said County Road No. 80 and the south right of way line of County Road No. 122 (Prosper Trail) (Variable Width Right of Way); THENCE North 44 degrees 51 minutes 46 seconds East with said intersection of County Road No. 80 and County Road No. 122, a distance of 35.31 feet to a 1/2 inch rebar capped "JBI" found for the northwest corner of said Lot 4R-C and lying on the south right of way line of said County Road No. 122; THENCE North 89 degrees 56 minutes 07 seconds East, with the south right of way line of said County Road No. 122, a distance of 175.00 feet to a 1/2 inch rebar capped "JBI" found for corner; THENCE North 86 degrees 06 minutes 46 seconds East with the south right of way line of said County Road No. 122, a distance of 90.21 feet to a 1/2 inch rebar capped "JBI" found for the northwest corner of Lot 3-C, Block A, Whispering Farms Commercial Center, an addition to the Town of Prosper as recorded in Document Number 2006-89, Plat Records, Collin County, Texas; THENCE South 00 degrees 26 minutes 14 seconds East departing the south right of way line of said County Road No. 122, with the west line of said Lot 3-C, a distance of 296.56 feet to a 1/2 inch rebar found for a northwest corner of Lot 2X, Block A (35 foot public trail), Whispering Farms Phase 1, an addition to the Town of Prosper, as recorded in Cabinet Q, Page 176, Plat Records, Collin County, Texas, also being the northeast corner of said Lot 4-D; THENCE South 89 degrees 50 minutes 59 seconds West, with the north line of said Lot 4-D, a distance of 297.76 feet to THE POINT OF BEGINNING and containing 84,805 square feet or 1.947 acres of land, more or less. NOW, THEREFORE, KNOW ALL MEN BY THESE PRESENTS THAT Dermatology Assets of Prosper, LLC does hereby certify and adopt this plat designating the herein above described property as FINAL PLAT OF LOT 4R-C1, BLOCK A WHISPERING FARMS COMMERCIAL CENTER, and does hereby dedicate to the public use forever, the streets and alleys shown thereon. Dermatology Assets of Prosper, LLC, does herein certify the following: 1.The streets and alleys are dedicated for street and alley purposes. 2.All public improvements and dedications shall be free and clear of all debt, liens, and/or encumbrances. 3.The easements and public use areas, as shown, are dedicated to the public use forever for the purposes indicated on this plat. 4.No buildings, fences, trees, shrubs or other improvements or growths shall be constructed or placed upon, over or across the easements as shown, except that landscape improvements may be placed in landscape easements if approved by the Town of Prosper. 5.The Town of Prosper is not responsible for replacing any improvements in, under, or over any easements caused by maintenance or repair. 6.Utility easements may also be used for the mutual use and accommodation of all public utilities desiring to use or using the same unless the easement limits the use to particular utilities, said use by the public utilities being subordinate to the public's and Town of Prosper's use thereof. 7.The Town of Prosper and public utilities shall have the right to remove and keep removed all or parts of any buildings, fences, trees, shrubs or other improvements or growths which may in any way endanger or interfere with the construction, maintenance, or efficiency of their respective systems in the easements. 8.The Town of Prosper and public utilities shall at all times have the full right of ingress and egress to or from their respective easements for the purpose of constructing, reconstructing, inspecting, patrolling, maintaining, reading meters, and adding to or removing all or parts of their respective systems without the necessity at any time procuring permission from anyone. 9.All modifications to this document shall be by means of plat and approved by the Town of Prosper. This plat approved subject to all platting ordinances, rules, regulations and resolutions of the Town of Prosper, Texas. WITNESS MY HAND AND SEAL OF OFFICE, this _____ day of ___________________, 20_____. DERMATOLOGY ASSETS OF PROSPER, LLC By: _________________________________ __________________ (Name) ____________________ (Position) STATE OF TEXAS COUNTY OF ______________ BEFORE ME, the undersigned authority, a Notary Public in and for the State of Texas, on this day personally appeared__________________________, known to me to be the person whose name is subscribed to the foregoing instrument and acknowledged to me that she executed the same for the purposes and consideration therein expressed. GIVEN UNDER MY HAND AND SEAL OF OFFICE this ________day of ______________________ 20____. ___________________________________ Notary Public in and for the State of Texas SCALE: 1" = 20' 20'0 10'20'40' ENGINEER 1903 Central Drive Suite #406 Bedford, Texas 76021 Phone: 817-281-0572 PRELIMINARY STATE OF TEXAS COUNTY OF DENTON This is to certify that I, Thomas W. Mauk, a Registered Professional Land Surveyor of the State of Texas, have platted the subdivision from an actual survey on the ground, and that this plat correctly represents that survey made by me or under my direction and supervision. ______________________________ Thomas W. Mauk, R.P.L.S. No. 5119 STATE OF TEXAS COUNTY OF DENTON BEFORE ME, the undersigned authority, a Notary Public in and for the State of Texas, on this day personally appeared Thomas W. Mauk, known to me to be the person whose name is subscribed to the foregoing instrument and acknowledged to me that she executed the same for the purposes and consideration therein expressed. GIVEN UNDER MY HAND AND SEAL OF OFFICE this ________day of ______________________ 20____. ___________________________________ Notary Public in and for the State of Texas LEGEND OF ABBREVIATIONS ·D.R.C.C.T. DEED RECORDS, COLLIN COUNTY, TEXAS ·O.P.R.C.C.T.OFFICIAL PUBLIC RECORDS, COLLIN COUNTY, TEXAS ·P.R.C.C.T.PLAT RECORDS, COLLIN COUNTY, TEXAS ·ROW RIGHT OF WAY ·IRS 1/2 INCH CAPPED REBAR STAMPED "WINDROSE" SET ·C.M.CONTROLLING MONUMENT CERTIFICATE OF APPROVAL: APPROVED THIS _____ DAY OF ____________, 20___ BY THE DIRECTOR OF DEVELOPMENT SERVICES OF THE TOWN OF PROSPER, TEXAS. _________________________TOWN SECRETARY _________________________ENGINEERING _________________________DEVELOPMENT SERVICES DEPARTMENT ACCESS EASEMENT The undersigned covenants and agrees that the access easement(s) may be utilized by any person or the general public for ingress and egress to other real property, and for the purpose of general vehicular use and access, and for the Fire Department, Police, and emergency use in, along, upon, and across said premises, with the right and privilege at all times of the Town of Prosper, its agents, employees, workmen, and representatives having ingress, egress, and regress in, along, upon, and across said premises. FIRE LANE EASEMENT The undersigned covenants and agrees that he (they) shall construct upon the Fire Lane Easements, as dedicated and shown hereon, a hard surface paved in accordance with town standards and that he (they) shall maintain the same in a state of good repair at all times and keep the same free and clear of any structures, fences, trees, shrubs, or other improvements or obstructions, including but not limited to the parking, loading, or unloading of motor vehicles, trailers, boats, or other impediments to the access of fire apparatus. The maintenance of pavement in accordance to town standards of the Fire Lane Easements is the responsibility of the owner, and the owner shall post and maintain signage in accordance to town standards in conspicuous places along the Fire Lanes, stating "Fire Lane, No Parking". The police or their duly authorized representative is hereby authorized to cause such fire lanes and utility easements to be maintained free and unobstructed at all times for Fire Department and emergency use. DRAWN BY: G.L.C. DATE: 11/01/2019 CHECKED BY: T.M. JOB NO.: 2019.9.375 220 ELM STREET, SUITE 200 I LEWISVILLE, TX 75057 I 214.217.2544 FIRM REGISTRATION NO. 10194331 I WINDROSESERVICES.COM ILAND SURVEYING PLATTING W I N D R O S E 220 Elm St., # 200 - Lewisville, TX 75057 Ph. 214.217.2544 - TFRN# 10063800 arthursurveying.com Established 1986 VICINITY MAP NOT TO SCALE SITE CASE NO. D19-0106 LANDSCAPE EASEMENT The undersigned covenants and agrees that the landscape easement and restrictions herein set forth shall run with the land and be binding on the owner(s) of the property in this subdivision, their successors and assigns, and all parties claiming by, through and under them. In the event a replat is requested on all or part of this property, the Town may require any similar or additional restrictions at its sole discretion. The sole responsibility for maintenance and replacement of landscape materials thereof shall be borne by any ‘homeowners’ association hereafter established for the owners of lots in this subdivision and/or the owners of the individual lots within this subdivision. Such maintenance and replacement shall be in conformance with the requirements, standards, and specifications of the Town of Prosper, as presently in effect or as may be hereafter amended. This provision may be enforced by specific performance or by any other remedy allowed by law. This Landscape Easement shall be void of utilities and other elements unless otherwise approved on the plat. The purpose of this Replat is to add and subtract easements. Page 1 of 3 To: Planning & Zoning Commission Item No. 4 From: Scott Ingalls, AICP, Senior Planner Through: Alex Glushko, AICP, Planning Manager Re: Planning & Zoning Commission Meeting – January 7, 2020 Agenda Item: Conduct a Public Hearing, and consider and act upon a request to amend Planned Development-91 (PD-91), for Cook Children’s North Campus, on 23.7± acres, located on the northeast corner of US 380 and Windsong Parkway, to modify the concept plans to accommodate an increased hospital size and modified parking. (Z19-0021). History: This item was tabled at the December 3, 2019, Planning & Zoning Commission meeting, per a request by the applicant. Description of Agenda Item: The zoning and land use of the surrounding properties are as follows: Zoning Current Land Use Future Land Use Plan Subject Property Planned Development-91- Retail Undeveloped US 380 District North Planned Development-40- Mixed Use and Specific Use Permit-15 House of Worship (St. Martin de Porres) US 380 District East Planned Development-40- Mixed Use and Specific Use Permit-15 House of Worship (St. Martin de Porres) US 380 District South City of Frisco Vacant City of Frisco West Planned Development-40- Mixed Use Windsong Ranch Marketplace US 380 District In August 2018, the Town Council approved Planned Development-91 (PD-91) for the Cook Children’s North Campus. The plan for the Medical Center included an Urgent Care and Prosper is a place where everyone matters. PLANNING Page 2 of 3 Primary Care Center, an Ambulatory Surgery Center, a Medical Office Building, a Helistop, an Outpatient Imaging and Data Center, and a 100 vehicle parking garage. PD-91 also called for a future Hospital of approximately 130,000 square feet. Construction of the Urgent Care and Primary Care Center has been completed and the Center is open to the public. The Medical Office Building, Ambulatory Surgery Center, and the Outpatient Imaging and Data Center are under construction. With this amendment, the applicant is requesting to amend the PD to update Exhibit D (Conceptual Site Plan), Exhibit F (Elevations), and Exhibit G (Landscape Plan) to define the hospital including the building area, elevations, and parking, as detailed below: 1.Hospital Expansion – The applicant is proposing to increase the size of the Hospital from 130,000 square feet as shown on the originally approved PD, to 230,000 square feet, an increase of approximately 100,000 square feet. The building will remain five (5) stories in height and will have a non-occupied space that will increase the overall height of the building to 109 feet for the blue roof peaks. The existing Exhibit C Development Standards allow for non-occupied space to exceed the maximum height of 75 feet. The proposed hospital addition is outlined in red and depicted below. Originally Approved Hospital Area (130,000 sq. ft.) Proposed Hospital Area (230,000 sq. ft.) Page 3 of 3 South Elevation (Note: Hospital elevations were not previously included in PD-91.) 2. Parking – With the increase in square feet for the Hospital, the applicant is proposing to eliminate the previously proposed parking garage and increase the amount of surface parking. The depicted number of off-street parking spaces meets the minimum standards of the Zoning Ordinance. Exhibit A (Legal Description), Exhibit B (Purpose Statement), and Exhibit C (Development Standards) are not being modified. Future Land Use Plan – The Future Land Use Plan recommends US 380 District for the property; the proposed amendment conforms to the Future Land Use Plan. Thoroughfare Plan – The property has direct access to US 380, a six-lane divided thoroughfare. The zoning exhibit complies with the Thoroughfare Plan. Parks Master Plan – The Parks Master Plan does not identify a park on the subject property. Legal Obligations and Review: Notification was provided to neighboring property owners, as required by state law. Town staff has not received any Public Hearing Notice Reply Forms. Attached Documents: 1. Location and Zoning Maps 2. Current Exhibits A, B, C, D, E, F, and G 3. Proposed Exhibits A, B, C, D, E, F, and G Staff Recommendation: Staff recommends the Planning & Zoning Commission approve the request to amend Planned Development-91 (PD-91), for Cook Children’s North Campus, on 23.7± acres, located on the northeast corner of US 380 and Windsong Parkway. Town Council Public Hearing: Upon a recommendation by the Planning & Zoning Commission, a Public Hearing on this item will be scheduled for the Town Council at their Regular meeting on January 28, 2020. UNIVERSITY DRWINDSONG PKWYDALEA DR PEQUIN DR BLUESTEM DRZ19-0021 ±0 375 750187.5 Feet U N IV E R S IT Y D RWINDSONG PKWYDALEA DR PEQUIN DR BLUESTEM DRZ19-0021 S-15 S-28 PD-40 PD-40 PD-91 PD-40 PD-40 PD-40 PD-40PD-40 PD-40 M M R M M SF TH M SF ±0 375 750187.5 Feet CURRENT PD EXHIBITS EXHIBIT "B" Statement of Intent and Purpose The property will be developed for a Primary Care Center, an Urgent Care Center, a Medical Office Building, an Ambulatory Surgery Center, a helistop, an Outpatient Imaging facility, a Data Center, a future Hospital, future outpatient services, and ancillary related uses such as wellness facilities and a parking garage. CURRENT PD EXHIBITS EXHIBIT "C" Development Standards The base zoning district for this PD is the “R” Retail District. The development regulations and permitted uses for the Retail District shall regulate the development of the property, except as provided in this exhibit. Except as otherwise set forth in these Development Standards, the regulations of the Town's Zoning Ordinance (Ordinance No. 05-20 as it currently exists or may be amended) and Subdivision Ordinance (Ordinance No. 17-41 as it currently exists or may be amended) shall apply. Building Height: Buildings shall be a maximum of five (5) stories, not to exceed seventy-five (75) feet in height. Additional height is necessary in medical office buildings for each floor to accommodate medical equipment. Seventy-five (75) feet in height will provide adequate height to allow five (5) stories at fifteen (15) feet each. Ornamental features may exceed the maximum building height provided that the ornamental feature does not contain floor area. Ornamental features include, but are not limited to, architectural features, parapets, mechanical equipment, and chimneys. Permitted Uses: All of the permitted uses in the “R” Retail District shall be allowed with the same provisions and restrictions including uses permitted by Specific Use Permit (SUP) and Conditional Uses (C). In addition, a Helistop shall be a permitted use without the requirement for a Specific Use Permit. Customized Architectural Standards: Section 8.2 of the Town of Prosper Zoning Ordinance regulating the Exterior Appearance of Buildings and Structures shall be complied with except for the following: A.Permitted primary exterior materials shall include stucco. B.The architectural façade drawings for the buildings shall be the basis for the architectural articulation (both horizontal and vertical), wall projections and building lengths permitted within this planned development. C.The Cook Children’s Medical Center signature blue standing-seam metal roofs and secondary green standing-seam metal roofs, and blue window mullions shall be allowed in this PD to compliment the neutrals, creams, and other non-reflective earth tone colors of the building. D.The elevations shall reflect horizontal features and capping on the stucco similar to the main façade of the building. The following provisions shall apply within this Planned Development. •The existing Windsong Community Entry monument signage, landscaping, and lighting shallbe permitted and preserved as it exists. CURRENT PD EXHIBITS •All surface parking lots shall have a landscape median strip with a minimum width of 6 feet incorporated into the parking lot design to separate the parking area and drive aisle with direct connection to the street. One (1) tree shall be planted for every 35 linear feet of median. •Intermittent berming outside the easements along US Highway 380 in the southeast corner of the project shall be required. CURRENT PD EXHIBITS ( IN FEET )0301201 inch= 60 ft.6060GRAPHIC SCALEPRELIMINARYFOR REVIEW ONLYTHESE DOCUMENTS ARE FORDESIGN REVIEW AND NOTINTENDED FORCONSTRUCTION, BIDDING ORPERMIT PURPOSES. THEYWERE PREPARED BY, ORUNDER THE SUPERVISION OF:P.E.# 124970JUSTIN T. WELLSDATE: 09/19/2019SITE LEGENDSHEET NO.PLOT DATE:EXHIBIT D09/19/2019ISSUE© 2018 HKS, INC.NO. DESCRIPTION DATEPDTEMPLATE VERSION:KEY PLANHKS, INC.FORT WORTH, TX 76102ARCHITECT1000 MACON STREET, SUITE 150DUNAWAY ASSOCIATESFORT WORTH, TX 76107STRUCTURAL / CIVIL ENGINEER550 BAILEY AVE, SUITE 400SMITH SECKMAN REID (SSR)DALLAS, TX 75201MEP ENGINEER3100 McKINNON ST., SUITE 550KELLER STUDIOFORT WORTH, TX 76104INTERIOR1263 W. ROSEDALE STREET, SUITE 201MITCHELL EQUIPMENT PLANNING SERVICESNORTHBROOK, IL, 60062MEDICAL EQUIPMENT630 DUNDEE, SUITE 340LINBECKFORT WORTH, TX 76104CONTRACTOR1263 W. ROSEDALE STREET, SUITE 201NORTH CAMPUSREVISIONHKS PROJECT NUMBERDATESHEET TITLEPLOT DATE:C1.0© 2018 HKS, INC.TEMPLATE VERSION:HKS, INC.FORT WORTH, TX 76102ARCHITECT1000 MACON STREET, SUITE 150DUNAWAY ASSOCIATES, TX REG. FIRM F-1114FORT WORTH, TX 76107STRUCTURAL / CIVIL ENGINEER /LANDSCAPE ARCHITECT550 BAILEY AVE, SUITE 400SMITH SECKMAN REID (SSR)DALLAS, TX 75201MEP ENGINEER3100 McKINNON ST., SUITE 550KELLER STUDIOFORT WORTH, TX 76104INTERIOR1263 W. ROSEDALE STREET, SUITE 201MITCHELL EQUIPMENT PLANNING SERVICESNORTHBROOK, IL, 60062MEDICAL EQUIPMENT630 DUNDEE, SUITE 340LINBECKFORT WORTH, TX 76104CONTRACTOR1263 W. ROSEDALE STREET, SUITE 201NORTH CAMPUSVICINITY MAPPROPERTY BOUNDARYYARD SETBACKEASEMENTFIRE LANE15PARKING COUNTBARRIER FREE RAMPBFRPROP. FIRE HYDRANTPROP. SEWER MHBACK OF CURBBOCFRONT OF CURBFOCPROPERTY LINE⅊PROP. CURB - PHASE 1PROP. CURB - FUTURE PHASEFIRE DEPARTMENT CONNECTIONFDCPROP. CURB INLETPROP. GRATE INLET∆ 23.65 ACRESMEDICAL OFFICEBUILDING67,500 SF8351513151581514URGENT CARECENTER10,330 SFPRIMARY CARE5,000 SFAMBULATORY SURGERYCENTER26,000 SFFUTURE HOSPITAL110,600 SFFUTUREHOSPITALEXPANSION17,400 SFFUTUREAMBULANCEENTRANCEFUTURE PARKINGGARAGE100 SPACESOP IMAGINGPLUS DATACENTER14,794 SFUNIVERSITY DRIVE (US 380)WINDSONG PARKWAY12121068310799558813121412981028151115712922351012121512111112151223PROJECT SITECURRENT PD EXHIBITS EXHIBIT "E" Development Schedule The anticipated schedule of development and approximate square footages of the uses and buildings are: • Phase 1: The initial phase will consist of one building with a Primary Care Center (5,000 square feet) and a Urgent Care Center (10,330 square feet) and a second building with an Ambulatory Surgery Center (26,000 square feet), Medical Offices (67,500 square feet), Outpatient Imaging (10,000 square feet) and a Data Center (1,000 square feet) within the next two (2) years. • Phase 2: An 110,600 square foot hospital and a 100 space parking garage within the next five (5) years. • Phase 3: A 17,400 square foot hospital addition within the next twelve (12) years. The development schedule, uses, and square footages are subject to change due to various factors beyond the control of the developer, such as market conditions, construction materials and labor availability and acts of nature, among others. CURRENT PD EXHIBITS LEVEL 01 100' - 0" LEVEL 02 116' - 0" LEVEL 03 130' - 0" ROOF 144' - 0" TOP OF SCREEN WALL 154' - 0" 1 2 3 4 5 6 7 8 9 10 11 LEVEL 01 100' - 0" LEVEL 02 116' - 0" LEVEL 03 130' - 0" ROOF 144' - 0" TOP OF SCREEN WALL 154' - 0" CDEFGHJKL • This Facade Plan is for conceptual purposes only. All building plans require review and approval from the Building Inspections Department. • All mechanical equipment shall be screened from public view. Rooftop mounted equipment shall be screened by a parapet wall or screening wall. Screening walls shall meet the specifications of the Zoning Ordinance. • When permitted, exposed utility boxes and conduits shall be painted to match the building. • All signage areas and locations are subject to approval by the Building Inspections Department. • Windows shall have a maximum exterior visible reflectivity of ten (10) percent. • Any deviation from the approved Facade Plan will require reapproval by the Town. I N T E R I M R E V I E W O N L Y Architect: Arch. Reg. No.: permit, or construction purposes. are not intended for regulatory approval, are released for interim review only and These documents are incomplete, and Date: REVISION HKS PROJECT NUMBER DATE SHEET TITLE SHEET NO.PLOT DATE:ISSUE © 2018 HKS, INC.TEMPLATE VERSION: KEY PLAN NORMAN TILMAN MORGAN 14364NORTH CAMPUS MOB / OP IMAGINGHKS, INC. FORT WORTH, TX 76102 ARCHITECT 1000 MACON STREET, SUITE 150 DUNAWAY ASSOCIATES FORT WORTH, TX 76107 STRUCTURAL / CIVIL ENGINEER/ LANDSCAPE ARCHITECT 550 BAILEY AVE, SUITE 400 SMITH SECKMAN REID (SSR) DALLAS, TX 75201 MEPT ENGINEER 3100 McKINNON ST., SUITE 550 KELLER STUDIO INC. FORT WORTH, TX 76104 INTERIOR DESIGNER 1263 W. ROSEDALE STREET, SUITE 101 MITCHELL EQUIPMENT PLANNING SERVICES NORTHBROOK, IL, 60062 MEDICAL EQUIPMENT 630 DUNDEE, SUITE 340 LINBECK FORT WORTH, TX 76104 CONTRACTOR 1263 W. ROSEDALE STREET, SUITE 202 EXECUTIVE ARCHITECT & PEDIATRIC HEALTHCARE DESIGNER WASHINGTON, D.C. 20036 1707 L ST. NW, SUITE #400 DESIGN ARCHITECT DAVID M. SCHWARZ ARCHITECTS, INC F -002874 9/19/2019 5:16:46 PMSP1.00 EXTERIOR ELEVATIONS 09/19/2019 21151.002 EXHIBIT F3.0.0.2017062309/19/2019 1/16" = 1'-0"01 SOUTH ELEVATION - MEDICAL OFFICE BUILDING/ASC 1/16" = 1'-0"02 WEST ELEVATION - MEDICAL OFFICE BUILDING/ASC 03 PERSPECTIVE - SOUTHWEST CORNER MEDICAL OFFICE BUILDING/ASC TOTAL STUCCO 1,348 18% TOTAL MANUF. STONE 3,008 40% TOTAL BRICK 3,187 42% STUCCO 01 1,348 18% MANUF. STONE 01 3,008 40% BRICK 02 1,611 21% BRICK 01 1,586 21% MATERIAL AREA (SF)PERCENTAGE OF SOLID FACADE TOTAL AREA 9,401 SF 100% TOTAL GLAZING 1,848 SF 20% TOTAL SOLID 7,553 SF 80% MOB/ASC WEST TOTAL STUCCO 2,708 21% TOTAL MANUF. STONE 4,749 37% TOTAL BRICK 5,298 42% STUCCO 01 2,708 21% MANUF. STONE 01 4,749 37% BRICK 02 2,634 21% BRICK 01 2,664 21% MATERIAL AREA (SF)PERCENTAGE OF SOLID FACADE TOTAL AREA 15,862 SF 100% TOTAL GLAZING 3,107 SF 20% TOTAL SOLID 12,755 SF 80% MOB/ASC SOUTH COOK CHILDREN'S EXISTING CAMPUS FOR REFERENCE EXTERIOR MATERIALS NO. DESCRIPTION DATE STANDING SEAM METAL ROOF - BLUE BRICK 01 MANUFACTURED STONE BRICK 02 MANUFACTURED STONE STANDING SEAM METAL ROOF - BLUE STUCCO 01 BRICK 01 MANUFACTURED STONE STUCCO 01 STANDING SEAM METAL ROOF - GREEN BRICK 01 MANUFACTURED STONE BRICK 02 BRICK 01 MANUFACTURED STONE 10'-0"CEILINGHEIGHT10'-0"CEILINGHEIGHT10'-0"CEILINGHEIGHT10'-0"CEILINGHEIGHT10'-0"CEILINGHEIGHT10'-0"CEILINGHEIGHTMATERIAL LEGEND MANUFACTURED STONE BRICK 01 BRICK 02 STUCCO 01 - TO MATCH BRICK 01 CURRENT PD EXHIBITS LEVEL 01 100' - 0" LEVEL 02 116' - 0" LEVEL 03 130' - 0" ROOF 144' - 0" TOP OF SCREEN WALL 154' - 0" 12345678 91011 LEVEL 01 100' - 0" LEVEL 02 116' - 0" LEVEL 03 130' - 0" ROOF 144' - 0" TOP OF SCREEN WALL 154' - 0" C D E F G H J K L • This Facade Plan is for conceptual purposes only. All building plans require review and approval from the Building Inspections Department. • All mechanical equipment shall be screened from public view. Rooftop mounted equipment shall be screened by a parapet wall or screening wall. Screening walls shall meet the specifications of the Zoning Ordinance. • When permitted, exposed utility boxes and conduits shall be painted to match the building. • All signage areas and locations are subject to approval by the Building Inspections Department. • Windows shall have a maximum exterior visible reflectivity of ten (10) percent. • Any deviation from the approved Facade Plan will require reapproval by the Town. I N T E R I M R E V I E W O N L Y Architect: Arch. Reg. No.: permit, or construction purposes. are not intended for regulatory approval, are released for interim review only and These documents are incomplete, and Date: REVISION HKS PROJECT NUMBER DATE SHEET TITLE SHEET NO.PLOT DATE:ISSUE © 2018 HKS, INC.TEMPLATE VERSION: KEY PLAN NORMAN TILMAN MORGAN 14364NORTH CAMPUS MOB / OP IMAGINGHKS, INC. FORT WORTH, TX 76102 ARCHITECT 1000 MACON STREET, SUITE 150 DUNAWAY ASSOCIATES FORT WORTH, TX 76107 STRUCTURAL / CIVIL ENGINEER/ LANDSCAPE ARCHITECT 550 BAILEY AVE, SUITE 400 SMITH SECKMAN REID (SSR) DALLAS, TX 75201 MEPT ENGINEER 3100 McKINNON ST., SUITE 550 KELLER STUDIO INC. FORT WORTH, TX 76104 INTERIOR DESIGNER 1263 W. ROSEDALE STREET, SUITE 101 MITCHELL EQUIPMENT PLANNING SERVICES NORTHBROOK, IL, 60062 MEDICAL EQUIPMENT 630 DUNDEE, SUITE 340 LINBECK FORT WORTH, TX 76104 CONTRACTOR 1263 W. ROSEDALE STREET, SUITE 202 EXECUTIVE ARCHITECT & PEDIATRIC HEALTHCARE DESIGNER WASHINGTON, D.C. 20036 1707 L ST. NW, SUITE #400 DESIGN ARCHITECT DAVID M. SCHWARZ ARCHITECTS, INC F -002874 9/19/2019 4:49:23 PMSP1.01 EXTERIOR ELEVATIONS 09/19/2019 21151.002 EXHIBIT F3.0.0.2017062309/19/2019 1/16" = 1'-0"01 NORTH ELEVATION - MEDICAL OFFICE BUILDING/ASC 1/16" = 1'-0"02 EAST ELEVATION - MEDICAL OFFICE BUILDING/ASC 03 PERSPECTIVE - NORTHEAST CORNER MEDICAL OFFICE BUILDING/ASC COOK CHILDREN'S EXISTING CAMPUS FOR REFERENCE EXTERIOR MATERIALS TOTAL STUCCO 2,197 23% TOTAL MANUF. STONE 3,107 34% TOTAL BRICK 3,956 43% STUCCO 01 2,197 23% MANUF. STONE 01 3,107 34% BRICK 02 1,662 18% BRICK 01 2,294 25% MATERIAL AREA (SF)PERCENTAGE OF SOLID FACADE TOTAL AREA 10,660 SF 100% TOTAL GLAZING 1,400 SF 13% TOTAL SOLID 9,260 SF 87% MOB/ASC EAST TOTAL STUCCO 3,095 23% TOTAL MANUF. STONE 4,409 33% TOTAL BRICK 5,836 44% STUCCO 01 3,095 24% MANUF. STONE 01 4,409 33% BRICK 02 2,998 22% BRICK 01 2,838 21% MATERIAL AREA (SF)PERCENTAGE OF SOLID FACADE TOTAL AREA 15,769 SF 100% TOTAL GLAZING 2,429 SF 15% TOTAL SOLID 13,340 SF 85% MOB/ASC NORTH NO.DESCRIPTION DATE BRICK 01 MANUFACTURED STONE 10'-0"CEILINGHEIGHT10'-0"CEILINGHEIGHT10'-0"CEILINGHEIGHTBRICK 02 10'-0"CEILINGHEIGHT10'-0"CEILINGHEIGHT10'-0"CEILINGHEIGHTBRICK 02 STUCCO 01 STUCCO 01 MANUFACTURED STONE BRICK 01 STUCCO 01 STUCCO 02 STUCCO 02 STUCCO 01 STUCCO 02 MATERIAL LEGEND MANUFACTURED STONE BRICK 01 BRICK 02 STUCCO 01 - TO MATCH BRICK 01 CURRENT PD EXHIBITS 09/19/2019CURRENT PD EXHIBITS CURRENT PD EXHIBITS CURRENT PD EXHIBITS WEST UNIVERSITY DRIVE (US 380) PROPOSED PD EXHIBITS Z19-0021 EXHIBIT "B" Statement of Intent and Purpose The primary use of the property will be for Primary Care Center, an Urgent Care Center, a Medical Office Building, an Ambulatory Surgery Center, a helistop, an Outpatient Imaging facility, a Data Center, a Hospital, and ancillary related uses such as parking, landscaping and open space. PROPOSED PD EXHIBITS Z19-0021 EXHIBIT "C" Development Standards The base zoning district for this PD is the “R” Retail District. The development regulations and permitted uses for the Retail District shall regulate the development of the property, except as provided in this exhibit. Except as otherwise set forth in these Development Standards, the regulations of the Town's Zoning Ordinance (Ordinance No. 05-20 as it currently exists or may be amended) and Subdivision Ordinance (Ordinance No. 17-41 as it currently exists or may be amended) shall apply. Building Height: Buildings shall be a maximum of five (5) stories, not to exceed seventy-five (75) feet in height. Additional height is needed in medical buildings for each floor to accommodate medical equipment. Seventy-five (75) feet in height will provide adequate height to allow five (5) stories at fifteen (15) feet each. Ornamental features may exceed the maximum building height provided that the ornamental feature does not contain floor area. Ornamental features include, but are not limited to, architectural features, parapets, mechanical equipment, and chimneys. Permitted Uses: All of the permitted uses in the “R” Retail District shall be allowed with the same provisions and restrictions including uses permitted by Specific Uses Permit (SUP) and Conditional Uses (C). In addition, a Helistop shall be a permitted use without the requirement for a Specific Use Permit. Customized Architectural Standards: Section 8.2 of the Town of Prosper Zoning Ordinance regulating the Exterior Appearance of Buildings and Structures shall be complied with except for the following: A. Permitted primary exterior materials shall include stucco. B. The architectural façade drawings for the buildings shall be the basis for the architectural articulation (both horizontal and vertical), wall projections and building lengths permitted within this planned development. C. The Cook Children’s Medical Center signature blue and clear standing-seam metal roofs and secondary green and red standing-seam metal roofs, and blue window mullions shall be allowed in this PD to compliment the neutrals, creams, and other non-reflective earth tone colors of the building. D. The elevations shall reflect horizontal features and capping on the stucco similar to the main façade of the building. The following provisions shall apply within this Planned Development. PROPOSED PD EXHIBITS •The existing Windsong Community Entry monument signage, landscaping, and lighting shall be permitted and preserved as it exists. •All surface parking lots shall have a landscape median strip with a minimum width of 6 feet incorporated into the parking lot design to separate the parking area and drive aisle with direct connection to the street. One (1) tree shall be planted for every 35 linear feet of median. •Intermittent berming outside the easements along US 380 in the southeast corner of the project shall be required. PROPOSED PD EXHIBITS WINDSONG PARKWAY UNIVERSITY DRIVE (US 380)11OFFICE BUILDING (MOB)67,764 SFURGENT CARECENTER (UCC)6,119 SFPRIMARY CARE (PC)8,869 SFAMBULATORY SURGERYCENTER (ASC)26,032 SF OP IMAGINGPLUS DATACENTER9,413 SF111196310798559613121412981129151115712922338109151415111515152 23.65 ACRES151025515151512914813131541133108PROPOSEDHOSPITAL230,000 SFWINDSONG PARKWAY UNIVERSITY DRIVE (US 380)SERVICE AREA /DOCKUTILITY PLANT &SERVICE YARD124314315151312151511155266314631515512PROJECT SITEFILENAME: SITE PLAN - PD.dwgPLOTTED BY: KATHERINE BRUNERPLOTTED ON: Wednesday, December 18, 2019PLOTTED AT: 8:48:18 AM © 2019 HKS, INC.FULL PATH: G:\Production4000\004500\4556\002\Civil\Drawings\Plot Sheets\SITE PLAN - PD.dwg HKS, INC.FORT WORTH, TX 76102ARCHITECT1000 MACON STREET, SUITE 150DUNAWAY ASSOCIATESFORT WORTH, TX 76107STRUCTURAL / CIVIL ENGINEER/LANDSCAPE ARCHITECT550 BAILEY AVE, SUITE 400SMITH SECKMAN REID (SSR)DALLAS, TX 75201MEP ENGINEER3100 McKINNON ST., SUITE 550KELLER STUDIOFORT WORTH, TX 76104INTERIOR DESIGNER1263 W. ROSEDALE STREET, SUITE 101MITCHELL EQUIPMENT PLANNING SERVICESNORTHBROOK, IL, 60062MEDICAL EQUIPMENT630 DUNDEE, SUITE 340LINBECKFORT WORTH, TX 76104CONTRACTOR1263 W. ROSEDALE STREET, SUITE 202EXECUTIVE ARCHITECT & PEDIATRICHEALTHCARE DESIGNERWASHINGTON, D.C. 20036 1707 L ST. NW, SUITE #400DESIGN ARCHITECTDAVID M. SCHWARZ ARCHITECTS, INCREVISIONHKS PROJECT NUMBERDATESHEET TITLESHEET NO.ISSUENO. DESCRIPTION DATEKEY PLANNORTH CAMPUSPRELIMINARYFOR REVIEW ONLYTHESE DOCUMENTS ARE FORDESIGN REVIEW AND NOTINTENDED FORCONSTRUCTION, BIDDING ORPERMIT PURPOSES. THEYWERE PREPARED BY, ORUNDER THE SUPERVISION OF:P.E.# 124970JUSTIN T. WELLSDATE: 12/16/2019SITE LEGENDPROPERTY BOUNDARYYARD SETBACKEASEMENTVICINITY MAPFIRE LANE15PARKING COUNTPROP. CURB - PHASE 2PROP. CURB - FUTURE PHASEFIRE LANE STRIPINGEXHIBIT DC1.001206060GRAPHIC SCALE IN FEETPD12/16/2019EXIST. CURB - PHASE 121151.007PROPOSED PD EXHIBITS Z19-0021 EXHIBIT "E" Development Schedule The anticipated schedule of development and approximate square footages of the uses and buildings are: •Phase 1: 117,098 sq. ft. being comprised of: 6,410 sq. ft. Primary Care Center and 6,330 sq. ft. Urgent Care Center in the western building and 26,032 sq. ft. Ambulatory Surgery Center and 67,764 sq. ft. Medical Office Building in eastern building, and a 9,413 sq. ft. Outpatient Imaging and a 1,150 sq. ft. Data Center within the next two (2) years. •Phase 2: 230,000 square foot hospital within the next five (5) years. The development schedule, uses, and square footages are subject to change due to various factors beyond the control of the developer, such as market conditions, construction materials and labor availability and acts of nature, among others. PROPOSED PD EXHIBITS Z19-0021 EXHIBIT "F" Illustrative Elevations and Plans The illustrations that are included with this Exhibit are for illustrative example only and do not constitute exact renderings or plans of the buildings and items depicted. PROPOSED PD EXHIBITS LEVEL 01 100' - 0" LEVEL 02 116' - 0" LEVEL 03 130' - 0" ROOF 144' - 0" TOP OF SCREEN WALL 154' - 0" METAL STANDING SEAM ROOF - BLUE 24' - 2"52' - 0"11' - 4"42' - 2"11' - 4"51' - 10"24' - 2"11' - 10"12' - 2"30' - 2"12' - 2"12' - 2" MANUF. STONE 01 BRICK 01 BRICK 02 STUCCO 01 BRICK 01 MANUF. STONE 01 MANUF. STONE 01 STUCCO 01 BRICK 02 MANUF. STONE 01 295' - 6" METAL STANDING SEAM ROOF - BLUE NOTE: ALL PUNCHED WINDOWS, GLAZED ALUMINUM FRAMING SYSTEMS AND ENTRY DOORS TO BE PAINTED BLUE TO MATCH ROOF10' - 0"14' - 0"14' - 0"16' - 0"11' - 3 1/2"3' - 11 1/2"66' - 3 1/2"LEVEL 01 100' - 0" LEVEL 02 116' - 0" LEVEL 03 130' - 0" ROOF 144' - 0" TOP OF SCREEN WALL 154' - 0" BRICK 01 MANUF. STONE 01 METAL STANDING SEAM ROOF - BLUE BRICK 02 BRICK 01 MANUF. STONE 01 BRICK 02 STUCCO 01 MANUF. STONE 01 STUCCO 01 BRICK 01 24' - 2"11' - 11"50' - 0"11' - 11"24' - 2"78' - 5"27' - 3 1/4" 227' - 10 1/4"10' - 0"14' - 0"14' - 0"16' - 0"7' - 4"4' - 11 1/2"• This Facade Plan is for conceptual purposes only. All building plans require review and approval from the Building Inspections Department. • All mechanical equipment shall be screened from public view. Rooftop mounted equipment shall be screened by a parapet wall or screening wall. Screening walls shall meet the specifications of the Zoning Ordinance. • When permitted, exposed utility boxes and conduits shall be painted to match the building. • All signage areas and locations are subject to approval by the Building Inspections Department. • Windows shall have a maximum exterior visible reflectivity of ten (10) percent. • Any deviation from the approved Facade Plan will require reapproval by the Town. BRICK 01 MANUFACTURED STONE 01 BRICK 02 METAL STANDING ROOF - BLUESTUCCO 01 METAL STANDING ROOF - GREENSTUCCO 02 MANUFACTURED STONE 02 MATERIAL LEGEND I N T E R I M R E V I E W O N L Y Architect: Arch. Reg. No.: permit, or construction purposes. are not intended for regulatory approval, are released for interim review only and These documents are incomplete, and Date: REVISION HKS PROJECT NUMBER DATE SHEET TITLE SHEET NO.PLOT DATE:ISSUE © 2018 HKS, INC.TEMPLATE VERSION: KEY PLAN NORMAN TILMAN MORGAN 14364NORTH CAMPUS MOB / OP IMAGINGHKS, INC. FORT WORTH, TX 76102 ARCHITECT 1000 MACON STREET, SUITE 150 DUNAWAY ASSOCIATES FORT WORTH, TX 76107 STRUCTURAL / CIVIL ENGINEER/ LANDSCAPE ARCHITECT 550 BAILEY AVE, SUITE 400 SMITH SECKMAN REID (SSR) DALLAS, TX 75201 MEPT ENGINEER 3100 McKINNON ST., SUITE 550 KELLER STUDIO INC. FORT WORTH, TX 76104 INTERIOR DESIGNER 1263 W. ROSEDALE STREET, SUITE 101 MITCHELL EQUIPMENT PLANNING SERVICES NORTHBROOK, IL, 60062 MEDICAL EQUIPMENT 630 DUNDEE, SUITE 340 LINBECK FORT WORTH, TX 76104 CONTRACTOR 1263 W. ROSEDALE STREET, SUITE 202 EXECUTIVE ARCHITECT & PEDIATRIC HEALTHCARE DESIGNER WASHINGTON, D.C. 20036 1707 L ST. NW, SUITE #400 DESIGN ARCHITECT DAVID M. SCHWARZ ARCHITECTS, INC F -002874 11/24/2019 6:59:17 PMSP1.00 EXTERIOR ELEVATIONS 11/04/2019 21151.002 EXHIBIT F3.0.0.2017062311/04/2019 1/16" = 1'-0"01 SOUTH ELEVATION - MEDICAL OFFICE BUILDING/ASC 1/16" = 1'-0"02 WEST ELEVATION - MEDICAL OFFICE BUILDING/ASC 03 PERSPECTIVE - SOUTHWEST CORNER MEDICAL OFFICE BUILDING/ASC TOTAL STUCCO 1,348 18% TOTAL MANUF. STONE 3,008 40% TOTAL BRICK 3,187 42% STUCCO 01 1,348 18% MANUF. STONE 01 3,008 40% BRICK 02 1,611 21% BRICK 01 1,586 21% MATERIAL AREA (SF)PERCENTAGE OF SOLID FACADE TOTAL AREA 9,401 SF 100% TOTAL GLAZING 1,848 SF 20% TOTAL SOLID 7,553 SF 80% MOB/ASC WEST TOTAL STUCCO 2,708 21% TOTAL MANUF. STONE 4,749 37% TOTAL BRICK 5,298 42% STUCCO 01 2,708 21% MANUF. STONE 01 4,749 37% BRICK 02 2,634 21% BRICK 01 2,664 21% MATERIAL AREA (SF)PERCENTAGE OF SOLID FACADE TOTAL AREA 15,862 SF 100% TOTAL GLAZING 3,107 SF 20% TOTAL SOLID 12,755 SF 80% MOB/ASC SOUTH EXTERIOR MATERIALS NO. DESCRIPTION DATE 1 Revision 01 11/19/19 2 Revision 02 11/25/19 CASE NUMBER: Z19-0021 PROPOSED PD EXHIBITS LEVEL 01 100' - 0" LEVEL 02 116' - 0" LEVEL 03 130' - 0" ROOF 144' - 0" TOP OF SCREEN WALL 154' - 0"16' - 0"14' - 0" 14' - 0" 10' - 0"11' - 3 1/2"3' - 11 1/2"24' - 3"36' - 0"24' - 0"48' - 8"24' - 0"36' - 8"23' - 4" 12' - 2" 12' - 0"30' - 4"12' - 0" 12' - 0"23' - 4"36' - 8"12' - 0" 14' - 4"22' - 0"12' - 0"38' - 4"12' - 0"22' - 0"24' - 2" 295' - 4" LEVEL 01 100' - 0" LEVEL 02 116' - 0" LEVEL 03 130' - 0" ROOF 144' - 0" TOP OF SCREEN WALL 154' - 0" 5' - 8 1/2"39' - 10 1/4"32' - 0"39' - 4"10' - 11 1/2"12' - 11 1/4"55' - 10"12' - 2"10' - 6"8' - 6" MANUF. STONE 01 STUCCO 01 BRICK 01 BRICK 02 MANUF. STONE 01 STUCCO 01 BRICK 01 BRICK 02 10' - 0"14' - 0"14' - 0"16' - 0"227' - 8 1/2" • This Facade Plan is for conceptual purposes only. All building plans require review and approval from the Building Inspections Department. • All mechanical equipment shall be screened from public view. Rooftop mounted equipment shall be screened by a parapet wall or screening wall. Screening walls shall meet the specifications of the Zoning Ordinance. • When permitted, exposed utility boxes and conduits shall be painted to match the building. • All signage areas and locations are subject to approval by the Building Inspections Department. • Windows shall have a maximum exterior visible reflectivity of ten (10) percent. • Any deviation from the approved Facade Plan will require reapproval by the Town. BRICK 01 MANUFACTURED STONE 01 BRICK 02 METAL STANDING ROOF - BLUESTUCCO 01 METAL STANDING ROOF - GREENSTUCCO 02 MANUFACTURED STONE 02 MATERIAL LEGEND I N T E R I M R E V I E W O N L Y Architect: Arch. Reg. No.: permit, or construction purposes. are not intended for regulatory approval, are released for interim review only and These documents are incomplete, and Date: REVISION HKS PROJECT NUMBER DATE SHEET TITLE SHEET NO.PLOT DATE:ISSUE © 2018 HKS, INC.TEMPLATE VERSION: KEY PLAN NORMAN TILMAN MORGAN 14364NORTH CAMPUS MOB / OP IMAGINGHKS, INC. FORT WORTH, TX 76102 ARCHITECT 1000 MACON STREET, SUITE 150 DUNAWAY ASSOCIATES FORT WORTH, TX 76107 STRUCTURAL / CIVIL ENGINEER/ LANDSCAPE ARCHITECT 550 BAILEY AVE, SUITE 400 SMITH SECKMAN REID (SSR) DALLAS, TX 75201 MEPT ENGINEER 3100 McKINNON ST., SUITE 550 KELLER STUDIO INC. FORT WORTH, TX 76104 INTERIOR DESIGNER 1263 W. ROSEDALE STREET, SUITE 101 MITCHELL EQUIPMENT PLANNING SERVICES NORTHBROOK, IL, 60062 MEDICAL EQUIPMENT 630 DUNDEE, SUITE 340 LINBECK FORT WORTH, TX 76104 CONTRACTOR 1263 W. ROSEDALE STREET, SUITE 202 EXECUTIVE ARCHITECT & PEDIATRIC HEALTHCARE DESIGNER WASHINGTON, D.C. 20036 1707 L ST. NW, SUITE #400 DESIGN ARCHITECT DAVID M. SCHWARZ ARCHITECTS, INC F -002874 11/24/2019 6:59:22 PMSP1.01 EXTERIOR ELEVATIONS 11/04/2019 21151.002 EXHIBIT F3.0.0.2017062311/04/2019 1/16" = 1'-0"01 NORTH ELEVATION - MEDICAL OFFICE BUILDING/ASC 1/16" = 1'-0"02 EAST ELEVATION - MEDICAL OFFICE BUILDING/ASC 03 PERSPECTIVE - NORTHEAST CORNER MEDICAL OFFICE BUILDING/ASC EXTERIOR MATERIALS TOTAL STUCCO 2,197 23% TOTAL MANUF. STONE 3,107 34% TOTAL BRICK 3,956 43% STUCCO 01 2,197 23% MANUF. STONE 01 3,107 34% BRICK 02 1,662 18% BRICK 01 2,294 25% MATERIAL AREA (SF)PERCENTAGE OF SOLID FACADE TOTAL AREA 10,660 SF 100% TOTAL GLAZING 1,400 SF 13% TOTAL SOLID 9,260 SF 87% MOB/ASC EAST TOTAL STUCCO 3,095 23% TOTAL MANUF. STONE 4,409 33% TOTAL BRICK 5,836 44% STUCCO 01 3,095 24% MANUF. STONE 01 4,409 33% BRICK 02 2,998 22% BRICK 01 2,838 21% MATERIAL AREA (SF)PERCENTAGE OF SOLID FACADE TOTAL AREA 15,769 SF 100% TOTAL GLAZING 2,429 SF 15% TOTAL SOLID 13,340 SF 85% MOB/ASC NORTH NO.DESCRIPTION DATE 1 Revision 01 11/19/19 2 Revision 02 11/25/19 STUCCO 01 BRICK 01 MANUF. STONE 01 METAL STANDING SEAM ROOF - BLUE BRICK 01 BRICK 02 MANUF. STONE 01 CASE NUMBER: Z19-0021 PROPOSED PD EXHIBITS LEVEL 01 100' - 0" MANUF. STONE 01 STUCCO 01 BRICK 01 STANDING SEAM METAL ROOF - BLUE 10' - 0"16' - 0"19' - 10"12' - 0"19' - 0" 3' - 0"29' - 4"3' - 0" 19' - 0"12' - 0"19' - 10" 137' - 0"6' - 7 1/8"32' - 7 1/8"LEVEL 01 100' - 0" MANUF. STONE 01 STUCCO 01 BRICK 01 STANDING SEAM METAL ROOF - BLUE 16' - 0" 10' - 0" 2' - 4"3' - 8" 17' - 8"24' - 2"52' - 6"24' - 0" 8"125' - 0" MANUF. STONE 01 STUCCO 01 BRICK 01 STANDING SEAM METAL ROOF - BLUE 10' - 0"16' - 0"12' - 2" 12' - 0"20' - 4"12' - 0"24' - 0"12' - 0"20' - 4"12' - 0" 12' - 2" 137' - 0"6' - 7 1/8"MANUF. STONE 01 STUCCO 01 BRICK 01 STANDING SEAM METAL ROOF - BLUE 10' - 0"16' - 0"3' - 8"12' - 0"5' - 8"24' - 0"52' - 8"24' - 0" 122' - 0" • This Facade Plan is for conceptual purposes only. All building plans require review and approval from the Building Inspections Department. • All mechanical equipment shall be screened from public view. Rooftop mounted equipment shall be screened by a parapet wall or screening wall. Screening walls shall meet the specifications of the Zoning Ordinance. • When permitted, exposed utility boxes and conduits shall be painted to match the building. • All signage areas and locations are subject to approval by the Building Inspections Department. • Windows shall have a maximum exterior visible reflectivity of ten (10) percent. • Any deviation from the approved Facade Plan will require reapproval by the Town. BRICK 01 MANUFACTURED STONE 01 BRICK 02 METAL STANDING ROOF - BLUESTUCCO 01 METAL STANDING ROOF - GREENSTUCCO 02 MANUFACTURED STONE 02 MATERIAL LEGEND I N T E R I M R E V I E W O N L Y Architect: Arch. Reg. No.: permit, or construction purposes. are not intended for regulatory approval, are released for interim review only and These documents are incomplete, and Date: REVISION HKS PROJECT NUMBER DATE SHEET TITLE SHEET NO.PLOT DATE:ISSUE © 2018 HKS, INC.TEMPLATE VERSION: KEY PLAN NORMAN TILMAN MORGAN 14364NORTH CAMPUS MOB / OP IMAGINGHKS, INC. FORT WORTH, TX 76102 ARCHITECT 1000 MACON STREET, SUITE 150 DUNAWAY ASSOCIATES FORT WORTH, TX 76107 STRUCTURAL / CIVIL ENGINEER/ LANDSCAPE ARCHITECT 550 BAILEY AVE, SUITE 400 SMITH SECKMAN REID (SSR) DALLAS, TX 75201 MEPT ENGINEER 3100 McKINNON ST., SUITE 550 KELLER STUDIO INC. FORT WORTH, TX 76104 INTERIOR DESIGNER 1263 W. ROSEDALE STREET, SUITE 101 MITCHELL EQUIPMENT PLANNING SERVICES NORTHBROOK, IL, 60062 MEDICAL EQUIPMENT 630 DUNDEE, SUITE 340 LINBECK FORT WORTH, TX 76104 CONTRACTOR 1263 W. ROSEDALE STREET, SUITE 202 EXECUTIVE ARCHITECT & PEDIATRIC HEALTHCARE DESIGNER WASHINGTON, D.C. 20036 1707 L ST. NW, SUITE #400 DESIGN ARCHITECT DAVID M. SCHWARZ ARCHITECTS, INC F -002874 11/24/2019 6:59:26 PMSP1.02 EXTERIOR ELEVATIONS 11/04/2019 21151.002 EXHIBIT F3.0.0.2017062311/04/2019 1/16" = 1'-0"01 EAST ELEVATION - UCC/PRIMARY CARE 1/16" = 1'-0"02 NORTH ELEVATION - UCC/PRIMARY CARE 1/16" = 1'-0"03 WEST ELEVATION - UCC/PRIMARY CARE 1/16" = 1'-0"04 SOUTH ELEVATION - UCC/PRIMARY CARE 05 PERSPECTIVE - SOUTHEAST CORNER UCC/PC 06 PERSPECTIVE - NORTHEAST CORNER UCC/PC STUCCO 01 560 19% BRICK 01 1,120 38% MANUF. STONE 01 1,276 43% MATERIAL AREA (SF)PERCENTAGE OF SOLID FACADE TOTAL AREA 3,516 SF 100% TOTAL GLAZING 560 SF 16% TOTAL SOLID 2,956 SF 84% UCC/PC EAST STUCCO 01 610 22% BRICK 01 942 33% MANUF. STONE 01 1,271 45% MATERIAL AREA (SF)PERCENTAGE OF SOLID FACADE TOTAL AREA 3,060 SF 100% TOTAL GLAZING 237 SF 8% TOTAL SOLID 2,823 SF 92% UCC/PC NORTH STUCCO 01 660 22% BRICK 01 1,154 39% MANUF. STONE 01 1,152 39% MATERIAL AREA (SF)PERCENTAGE OF SOLID FACADE TOTAL AREA 3,319 SF 100% TOTAL GLAZING 353 SF 11% TOTAL SOLID 2,966 SF 89% UCC/PC WEST STUCCO 01 610 22% BRICK 01 942 33% MANUF. STONE 01 1,283 45% MATERIAL AREA (SF)PERCENTAGE OF SOLID FACADE TOTAL AREA 3,060 SF 100% TOTAL GLAZING 225 SF 7% TOTAL SOLID 2,835 SF 93% UCC/PC SOUTH EXTERIOR MATERIALS NO. DESCRIPTION DATE 1 Revision 01 11/19/19 2 Revision 02 11/25/19 CASE NUMBER: Z19-0021 PROPOSED PD EXHIBITS Level 1 100' - 0" Level 2 116' - 0" Level 3 132' - 0" Level 4 146' - 0" Level 5 160' - 0" Roof 174' - 0" MANUFACTURED STONE BRICK 01+02 PAINTED METAL LOUVERS METAL STANDING SEAM ROOF GLASS CANOPY METAL STANDING SEAM ROOF NEW HOSPITALEXISTING MOB 107'-7"METAL CANOPY STUCCO STUCCO MANUFACTURED STONE BRICK 01 BRICK 02 STUCCO 01 -(COLOR TO MATCH BRICK 01) MATERIAL LEGEND: METAL STANDING SEAM ROOF -RED METAL STANDING SEAM ROOF -BLUE GLASS CANOPY Level 1 100' - 0" Level 2 116' - 0" Level 3 132' - 0" Level 4 146' - 0" Level 5 160' - 0" Roof 174' - 0" EXISTING MOB MANUFACTURED STONE BRICK 01 + 02 MANUFACTURED STONE STUCCO PAINTED METAL LOUVERS GLASS CANOPY METAL STANDING SEAM ROOF REVISION HKS PROJECT NUMBER DATE SHEET TITLE SHEET NO.PLOT DATE:ISSUE © 2018 HKS, INC.TEMPLATE VERSION: KEY PLAN HKS, INC. FORT WORTH, TX 76102 ARCHITECT 1000 MACON STREET, SUITE 150 DUNAWAY ASSOCIATES FORT WORTH, TX 76107 STRUCTURAL / CIVIL ENGINEER / LANDSCAPE ARCHITECT 550 BAILEY AVE, SUITE 400 SMITH SECKMAN REID (SSR) DALLAS, TX 75201 MEP ENGINEER 3100 McKINNON ST., SUITE 550 KELLER STUDIO FORT WORTH, TX 76104 INTERIOR DESIGN 1263 W. ROSEDALE STREET, SUITE 201 MITCHELL EQUIPMENT PLANNING SERVICES NORTHBROOK, IL, 60062 MEDICAL EQUIPMENT 630 DUNDEE, SUITE 340 LINBECK FORT WORTH, TX 76104 CONTRACTOR 1263 W. ROSEDALE STREET, SUITE 201 NORTH CAMPUS DAVID M. SCHWARZ ARCHITECTS, INC. WASHINGTON, D.C. 20036 DESIGN ARCHITECT 1707 L ST. NW, SUITE #400 EXHIBIT F CASE NUMBER: Z19-0021 12/17/2019 12:19:03 PMSP1.03 HOSPITAL EXTERIOR ELEVATIONS-SOUTH AND WEST 11/04/19 21151.007 1/16" = 1'-0"01 SOUTH ELEVATION - CCMC PROSPER HOSPITAL CCNC HOSPITAL -SOUTH TOTAL SOLID AREA (SF)MATERIAL PERCENTAGE OF SOLID FACADE EXTERIOR MATERIALS TOTAL GLAZING TOTAL AREA BRICK 01 + 02 MANUF. STONE 01 STUCCO 01 PTD. METAL LOUVERS 17,264 78% 4,749 22% 22,013 100% 9,806 57% 6,265 36% 775 5% 418 2% 1/16" = 1'-0"02 WEST ELEVATION - CCMC PROSPER HOSPITAL CCNC HOSPITAL -WEST TOTAL SOLID AREA (SF)MATERIAL PERCENTAGE OF SOLID FACADE TOTAL GLAZING TOTAL AREA BRICK 01 + 02 MANUF. STONE 01 STUCCO 01 PTD. METAL LOUVERS 15,546 82% 3,517 18% 19,063 100% 8,758 56% 3,735 24% 2,207 14% 846 6% • This Facade Plan is for conceptual purposes only. All building plans require review and approval from the Building Inspections Department. • All mechanical equipment shall be screened from public view. Rooftop mounted equipment shall be screened by a parapet wall or screening wall. Screening walls shall meet the specifications of the Zoning Ordinance. • When permitted, exposed utility bozes and conduits shall be painted to match the building • All signage areas and locations are subject to approval by the Building Inspections Department • Windows shall have a mazimum exterior visible reflectivity of ten (10) percent. • Any deviation from the approved Facade Plan will require reapproval by the Town. *Roof terraces and courtyards at level 3 (masonry walls and glazing) are not included in material take-offs. Design and location are TBD. *West side of level 4 mechanical penthouse accounted for in material take- offs. NO. DESCRIPTION DATE 1 Revision 1 11/19/19 2 Revision 2 11/22/19 3 Revision 3 12/17/19 PROPOSED PD EXHIBITS Level 1 100' - 0" Level 2 116' - 0" Level 3 132' - 0" Level 4 146' - 0" Level 5 160' - 0" Roof 174' - 0" MANUFACTURED STONE PAINTED METAL LOUVERS STUCCO MASONRY SCREEN WALL (BRICK 01 + 02, 10'-0" TALL) AT LOADING AND TRASH AREA MANUFACTURED STONE BRICK 01 + 02 NEW HOSPITAL EXISTING MOB METAL STANDING SEAM ROOF 107'-7"BRICK 01 + 02 BRICK 01 + 02 STUCCO MASONRY SCREEN WALL (BRICK 01 + 02, 8'-0" TALL) MANUFACTURED STONE BRICK 01 BRICK 02 STUCCO 01 -(COLOR TO MATCH BRICK 01) MATERIAL LEGEND: METAL STANDING SEAM ROOF -RED METAL STANDING SEAM ROOF -BLUE GLASS CANOPY Level 1 100' - 0" Level 2 116' - 0" Level 3 132' - 0" Level 4 146' - 0" Level 5 160' - 0" Roof 174' - 0" PAINTED METAL LOUVERS BRICK 01 + 02 MANUFACTURED STONE MANUFACTURED STONE METAL STANDING SEAM ROOF MASONRY SCREEN WALL (BRICK 01 + 02, 8'-0" TALL) METAL STANDING SEAM CANOPY MASONRY SCREEN WALL (BRICK 01 + 02, 10'-0" TALL) BETWEEN EMERGENCY DROP-OFFS REVISION HKS PROJECT NUMBER DATE SHEET TITLE SHEET NO.PLOT DATE:ISSUE © 2018 HKS, INC.TEMPLATE VERSION: KEY PLAN HKS, INC. FORT WORTH, TX 76102 ARCHITECT 1000 MACON STREET, SUITE 150 DUNAWAY ASSOCIATES FORT WORTH, TX 76107 STRUCTURAL / CIVIL ENGINEER / LANDSCAPE ARCHITECT 550 BAILEY AVE, SUITE 400 SMITH SECKMAN REID (SSR) DALLAS, TX 75201 MEP ENGINEER 3100 McKINNON ST., SUITE 550 KELLER STUDIO FORT WORTH, TX 76104 INTERIOR DESIGN 1263 W. ROSEDALE STREET, SUITE 201 MITCHELL EQUIPMENT PLANNING SERVICES NORTHBROOK, IL, 60062 MEDICAL EQUIPMENT 630 DUNDEE, SUITE 340 LINBECK FORT WORTH, TX 76104 CONTRACTOR 1263 W. ROSEDALE STREET, SUITE 201 NORTH CAMPUS DAVID M. SCHWARZ ARCHITECTS, INC. WASHINGTON, D.C. 20036 DESIGN ARCHITECT 1707 L ST. NW, SUITE #400 EXHIBIT F CASE NUMBER: Z19-0021 12/17/2019 12:19:14 PMSP1.04 HOSPITAL EXTERIOR ELEVATIONS-NORTH AND EAST 11/04/19 21151.007 1/16" = 1'-0"01 NORTH ELEVATION - CCMC PROSPER HOSPITAL CCNC HOSPITAL -NORTH TOTAL SOLID AREA (SF)MATERIAL PERCENTAGE OF SOLID FACADE EXTERIOR MATERIALS TOTAL GLAZING TOTAL AREA BRICK 01 + 02 MANUF. STONE 01 STUCCO 01 PTD. METAL LOUVERS 18,024 85% 3,166 15% 21,190 100% 9,680 54% 5,727 32% 777 4% 1,840 10% CCNC HOSPITAL -EAST TOTAL SOLID AREA (SF)MATERIAL PERCENTAGE OF SOLID FACADE TOTAL GLAZING TOTAL AREA BRICK 01 + 02 MANUF. STONE 01 STUCCO 01 PTD. METAL LOUVERS •This Facade Plan is for conceptual purposes only. All building plans require review and approval from the Building Inspections Department. •All mechanical equipment shall be screened from public view. Rooftop mounted equipment shall be screened by a parapet wall or screening wall. Screening walls shall meet the specifications of the Zoning Ordinance. •When permitted, exposed utility bozes and conduits shall be painted to match the building •All signage areas and locations are subject to approval by the Building Inspections Department •Windows shall have a mazimum exterior visible reflectivity of ten (10) percent. •Any deviation from the approved Facade Plan will require reapproval by the Town. 1/16" = 1'-0"02 EAST ELEVATION - CCMC PROSPER HOSPITAL 21,819 82% 4,662 18% 26,481 100% 9,998 46% 4,997 23% 5,251 24% 1,572 7% *Roof terraces and courtyards at level 3 (masonry walls and glazing) are not included in material take-offs. Design and location are TBD. *West side of level 4 mechanical penthouse accounted for in material take- offs. NO. DESCRIPTION DATE 1 Revision 1 11/19/19 2 Revision 2 11/22/19 3 Revision 3 12/17/19 PROPOSED PD EXHIBITS REVISION HKS PROJECT NUMBER DATE SHEET TITLE SHEET NO.PLOT DATE:ISSUE © 2018 HKS, INC.TEMPLATE VERSION: KEY PLAN HKS, INC. FORT WORTH, TX 76102 ARCHITECT 1000 MACON STREET, SUITE 150 DUNAWAY ASSOCIATES FORT WORTH, TX 76107 STRUCTURAL / CIVIL ENGINEER / LANDSCAPE ARCHITECT 550 BAILEY AVE, SUITE 400 SMITH SECKMAN REID (SSR) DALLAS, TX 75201 MEP ENGINEER 3100 McKINNON ST., SUITE 550 KELLER STUDIO FORT WORTH, TX 76104 INTERIOR DESIGN 1263 W. ROSEDALE STREET, SUITE 201 MITCHELL EQUIPMENT PLANNING SERVICES NORTHBROOK, IL, 60062 MEDICAL EQUIPMENT 630 DUNDEE, SUITE 340 LINBECK FORT WORTH, TX 76104 CONTRACTOR 1263 W. ROSEDALE STREET, SUITE 201 NORTH CAMPUS DAVID M. SCHWARZ ARCHITECTS, INC. WASHINGTON, D.C. 20036 DESIGN ARCHITECT 1707 L ST. NW, SUITE #400 EXHIBIT F CASE NUMBER: Z19-0021 12/17/2019 12:20:51 PMSP1.05 HOSPITAL EXTERIOR ELEVATIONS- PERSPECTIVES 11/04/19 21151.007 02 PERSPECTIVE - SOUTHEAST CORNER CCMC PROSPER HOSPITAL01 PERSPECTIVE - SOUTHWEST CORNER CCMC PROSPER HOSPITAL 03 PERSPECTIVE - NORTHWEST CORNER CCMC PROSPER HOSPITAL 04 PERSPECTIVE- WEST FACADE CCMC PROSPER HOSPITAL NO. DESCRIPTION DATE 1 Revision 1 11/19/19 2 Revision 2 11/22/19 3 Revision 3 12/17/19 PROPOSED PD EXHIBITS Z19-0021 EXHIBIT "G" Conceptual PD Landscape Plans The Conceptual PD Landscape Plans that are submitted are conceptual and final landscape design and construction plans may vary. PROPOSED PD EXHIBITS FILENAME: LANDSCAPE_PD.dwgPLOTTED BY: KATHERINE BRUNERPLOTTED ON: Wednesday, December 18, 2019PLOTTED AT: 8:40:04 AM © 2019 HKS, INC.FULL PATH: G:\Production4000\004500\4556\002\Civil\Drawings\Plot Sheets\LANDSCAPE_PD.dwg HKS, INC.FORT WORTH, TX 76102ARCHITECT1000 MACON STREET, SUITE 150DUNAWAY ASSOCIATESFORT WORTH, TX 76107STRUCTURAL / CIVIL ENGINEER/LANDSCAPE ARCHITECT550 BAILEY AVE, SUITE 400SMITH SECKMAN REID (SSR)DALLAS, TX 75201MEP ENGINEER3100 McKINNON ST., SUITE 550KELLER STUDIOFORT WORTH, TX 76104INTERIOR DESIGNER1263 W. ROSEDALE STREET, SUITE 101SMITH SECKMAN REID (SSR)DALLAS, TX 75201MEDICAL EQUIPMENT3100 McKINNON ST., SUITE 550LINBECKFORT WORTH, TX 76104CONTRACTOR1263 W. ROSEDALE STREET, SUITE 202EXECUTIVE ARCHITECT & PEDIATRICHEALTHCARE DESIGNERWASHINGTON, D.C. 20036 1707 L ST. NW, SUITE #400DESIGN ARCHITECTDAVID M. SCHWARZ ARCHITECTS, INCREVISIONHKS PROJECT NUMBERDATESHEET TITLESHEET NO.ISSUENO. DESCRIPTION DATEKEY PLANNORTH CAMPUSPRELIMINARYFOR REVIEW ONLYThese documents are forDesign Review and notintended forConstruction, Bidding orPermit Purposes. Theywere prepared by, orunder the supervision of:Anita M. BeardL.A.#295312/17/2019(TX REG. F-1114)SITE LEGENDPROPERTY BOUNDARYYARD SETBACKEASEMENT© 2018 HKS, INC.© 2018 HKS, INC.FIRE LANE15PARKING COUNTBARRIER FREE RAMPBFR’“”” ” ’ ’ ’VEGETATION AREA TO REMAINREFER TO SHEET L1.2 FOR COMPLETE PLANT SCHEDULE.REFER TO SHEET L1.3 FOR TYPICAL PLANTING DETAILS.01206060GRAPHIC SCALE IN FEETEXHIBIT GL1.1PD12/16/201921151.007WINDSONG PARKWAY UNIVERSITY DRIVE (US 380)EX-8'' SS10' LANDSCAPESETBACK VIA MOU 25' LANDSCAPESETBACK506.3'959.9'168.2'509.8'328.2'211.7'75' WATER TRANSMISSIONEASEMENT 5' L A N D S C A P E SE T B A C K25' LANDSCAPESETBACK MEDICAL OFFICEBUILDING67,764 SFURGENT CARECENTER6,119 SFPRIMARY CARE8,869 SFAMBULATORY SURGERYCENTER26,032 SFDRIVEWAYDRIVEWAYDRIVEWAYDRIVEWAY OP / IMAGING PLUSDATA CENTER9,413 SF6' PUBLIC SIDEWALK6' PROP.PUBLIC SIDEWALK6' PUBLIC SIDEWALK5' PROP. PUBLIC SIDEWALKTO CONNECT TO EX.SIDEWALKHELISTOP(50'X50')DUMPSTERLOCATION3' BERMDUMPSTERLOCATIONPROPOSEDHOSPITALEXPANSION230,000 SF5' LANDSCAPESETBACK3' BERMUTILITY PLANT &SERVICE YARD6' PUBLIC SIDEWALKFUTURE GARDEN SPACEAPPROX. 1,000 SFFUTURE GARDEN SPACEAPPROX. 2,000 SF30' LANDSCAPEEASEMENT 7" CAL / 20' CANOPYRED OAK, TO REMAINAND BE PROTECTEDLANDSCAPE SITE DATAREQUIREDPROVIDEDPerimeter RequirementsUS 380 University Drive One large tree for every 30' of frontage1,228' / 30'41 Large Trees35 Large Trees24 Small Trees15 Shrubs for every 30' of frontage1,228' / 30' (x15)614 Shrubs1,340 ShrubsWindsong PkwyOne large tree for every 30' of frontage 23 Large Trees16 Large Trees685' / 30'15 Small Trees15 shrubs for every 30' of frontage685' / 30' (x15)343 Shrubs688 ShrubsNon-Residential adjacencyOne small tree for every 15'1,942' / 15'130 Small Trees130 Small TreesOne shrub every for every 15'1,942' / 15'130 Shrubs164 ShrubsInterior Parking Requirements15 sf. of landscape for each space809 spaces x 15 sf.12,135 sf. 15,637 sf.Landscape islands shall contain1 large tree 15 islands yesyesOne large tree within 150' of spaceyesyesBuilding Landcaping / Foundation PlantingOne large tree, located within 30' of buildingfor every 10,000 sf. building area204,000 sf. building area / 10,000 20 - 3" caliper Large Trees 16 - 3" caliper Large Trees19 - 3" caliper Ornamental TreesPROPOSED PD EXHIBITS ANTICIPATED SPECIES LIST6+R8B6CATE*ORYCODE*RO8NDCOVER6 / ORNAMENTAL *RA66E6CATE*ORYFILENAME: LANDSCAPE_PD.dwgPLOTTED BY: KATHERINE BRUNERPLOTTED ON: Wednesday, December 18, 2019PLOTTED AT: 8:40:14 AM © 2019 HKS, INC.FULL PATH: G:\Production4000\004500\4556\002\Civil\Drawings\Plot Sheets\LANDSCAPE_PD.dwg HKS, INC.FORT WORTH, TX 76102ARCHITECT1000 MACON STREET, SUITE 150DUNAWAY ASSOCIATESFORT WORTH, TX 76107STRUCTURAL / CIVIL ENGINEER/LANDSCAPE ARCHITECT550 BAILEY AVE, SUITE 400SMITH SECKMAN REID (SSR)DALLAS, TX 75201MEP ENGINEER3100 McKINNON ST., SUITE 550KELLER STUDIOFORT WORTH, TX 76104INTERIOR DESIGNER1263 W. ROSEDALE STREET, SUITE 101SMITH SECKMAN REID (SSR)DALLAS, TX 75201MEDICAL EQUIPMENT3100 McKINNON ST., SUITE 550LINBECKFORT WORTH, TX 76104CONTRACTOR1263 W. ROSEDALE STREET, SUITE 202EXECUTIVE ARCHITECT & PEDIATRICHEALTHCARE DESIGNERWASHINGTON, D.C. 20036 1707 L ST. NW, SUITE #400DESIGN ARCHITECTDAVID M. SCHWARZ ARCHITECTS, INCREVISIONHKS PROJECT NUMBERDATESHEET TITLESHEET NO.ISSUENO. DESCRIPTION DATEKEY PLANNORTH CAMPUSPRELIMINARYFOR REVIEW ONLYThese documents are forDesign Review and notintended forConstruction, Bidding orPermit Purposes. Theywere prepared by, orunder the supervision of:Anita M. BeardL.A.#295312/17/2019(TX REG. F-1114)EXHIBIT GL1.2LARGE TREESQTYCOMMON NAMEBOTANICAL NAMECAL.CONT.HEIGHTSPREAD5CEDAR ELMULMUS CRASSIFOLIA3"65 GAL 12`-14` 5`-7`3CHINESE PISTACHEPISTACIA CHINENSIS3"65 GAL 12`-14` 5`-7`4LIVE OAKQUERCUS VIRGINIANA3"65 GAL 12`-14` 5`-7`4SHUMARD OAKQUERCUS SHUMARDII3"65 GAL 12`-14` 5`-7`SMALL TREESQTYCOMMON NAMEBOTANICAL NAMECAL.CONT.HEIGHTSPREAD6CRAPE MYRTLE `MUSKOGEE` LAGERSTROEMIA X `MUSKOGEE` 3" MULTI-TRUNK 45 GAL. 8`-10` 4`-6`9ROUGHLEAF DOGWOOD CORNUS DRUMMONDII3" MULTI-TRUNK 45 GAL. 6`-8` 6`-8`SHRUB AREASQTYCOMMON NAMEBOTANICAL NAMECONT.HT.SPREADSPACING688 WSGWINDSONG5 GAL24"-36" 18"-24" 36"OCSOD/SEEDQTYCOMMON NAMEBOTANICAL NAMECONT.HEIGHTSPREADSPACING10,629 SF BERMUDA GRASSCYNODON DACTYLONSOLID SOD NA NA NAPLANT SCHEDULE WINDSONGSMALL TREESQTYCOMMON NAMEBOTANICAL NAMECAL.CONT.HEIGHTSPREAD59 BLUE POINT JUNIPER JUNIPERUS CHINENSIS `BLUE POINT` 3"45 GAL 6`-8` 6`-8`12ROUGHLEAF DOGWOOD CORNUS DRUMMONDII3" MULTI-TRUNK 45 GAL. 6`-8` 6`-8`62TEXAS REDBUDCERCIS CANADENSIS TEXENSIS 3"45 GAL 8`-10` 4`-6`SHRUB AREASQTYCOMMON NAMEBOTANICAL NAMECONT.HT.SPREADSPACING165 LSBLSB5 GAL24"-36" 18"-24" 36"OCSOD/SEEDQTYCOMMON NAMEBOTANICAL NAMECONT.HEIGHTSPREADSPACING10,383 SF BERMUDA GRASSCYNODON DACTYLONSOLID SOD NA NA NAPLANT SCHEDULE NON-RESIDENTIALLARGE TREESQTYCOMMON NAMEBOTANICAL NAMECAL.CONT.HEIGHTSPREAD23CATHEDRAL LIVE OAKQUERCUS VIRGINIANA `CATHEDRAL` 3"65 GAL 12`-14` 5`-7`17CEDAR ELMULMUS CRASSIFOLIA3"65 GAL 12`-14` 5`-7`43CHINESE PISTACHEPISTACIA CHINENSIS3"65 GAL 12`-14` 5`-7`3LACEBARK ELMULMUS PARVIFOLIA3"65 GAL 12`-14` 5`-7`21LACEY OAKQUERCUS LACEYI3"65 GAL 12`-14` 5`-7`44LIVE OAKQUERCUS VIRGINIANA3"65 GAL 12`-14` 5`-7`19SHUMARD OAKQUERCUS SHUMARDII3"65 GAL 12`-14` 5`-7`SMALL TREESQTYCOMMON NAMEBOTANICAL NAMECAL.CONT.HEIGHTSPREAD11BLUE POINT JUNIPERJUNIPERUS CHINENSIS `BLUE POINT` 3"45 GAL 6`-8` 6`-8`46CRAPE MYRTLE `MUSKOGEE` LAGERSTROEMIA X `MUSKOGEE`3" MULTI-TRUNK 45 GAL. 8`-10` 4`-6`36DWARF SOUTHERN MAGNOLIA MAGNOLIA GRANDIFLORA `LITTLE GEM` 3"45 GAL 6`-8` 5`-7`15MEXICAN PLUMPRUNUS MEXICANA3"45 GAL 8`-10` 8`-10`9TEXAS REDBUDCERCIS CANADENSIS TEXENSIS3"45 GAL 8`-10` 4`-6`SHRUB AREASQTYCOMMON NAMEBOTANICAL NAMECONT.HT.SPREADSPACING15,599 INTERIORINTERIOR5 GAL24"-36" 18"-24" 36"OCGROUND COVERSQTYCOMMON NAMEBOTANICAL NAMECONT.HEIGHTSPREADSPACING12SEASONAL COLORSEASONAL COLOR4" POTS4"-6" 4"-6" 12" OC.SOD/SEEDQTYCOMMON NAMEBOTANICAL NAMECONT.HEIGHTSPREADSPACING140,449 SF BERMUDA GRASSCYNODON DACTYLONSOLID SOD NA NA NAPLANT SCHEDULE INTERIORLANDSCAPE SITE DATAREQUIREDPROVIDEDPerimeter RequirementsUS 380 University Drive One large tree for every 30' of frontage1,228' / 30'41 Large Trees35 Large Trees24 Small Trees15 Shrubs for every 30' of frontage1,228' / 30' (x15)614 Shrubs1,340 ShrubsWindsong PkwyOne large tree for every 30' of frontage 23 Large Trees16 Large Trees685' / 30'15 Small Trees15 shrubs for every 30' of frontage685' / 30' (x15)343 Shrubs688 ShrubsNon-Residential adjacencyOne small tree for every 15'1,942' / 15'130 Small Trees130 Small TreesOne shrub every for every 15'1,942' / 15'130 Shrubs164 ShrubsInterior Parking Requirements15 sf. of landscape for each space809 spaces x 15 sf.12,135 sf. 15,637 sf.Landscape islands shall contain1 large tree 15 islands yesyesOne large tree within 150' of spaceyesyesBuilding Landcaping / Foundation PlantingOne large tree, located within 30' of buildingfor every 10,000 sf. building area204,000 sf. building area / 10,000 20 - 3" caliper Large Trees 16 - 3" caliper Large Trees19 - 3" caliper Ornamental TreesLARGE TREESQTYCOMMON NAMEBOTANICAL NAMECAL.CONT.HEIGHTSPREAD15BALD CYPRESS TAXODIUM DISTICHUM3"65 GAL 12`-14` 5`-7`6CEDAR ELMULMUS CRASSIFOLIA3"65 GAL 12`-14` 5`-7`8CHINESE PISTACHE PISTACIA CHINENSIS3"65 GAL 12`-14` 5`-7`6LACEY OAKQUERCUS LACEYI3"65 GAL 12`-14` 5`-7`SMALL TREESQTYCOMMON NAMEBOTANICAL NAMECAL.CONT.HEIGHTSPREAD15BLUE POINT JUNIPER JUNIPERUS CHINENSIS `BLUE POINT` 3"45 GAL 6`-8` 6`-8`9CHASTE TREEVITEX AGNUS-CASTUS3" MULTI-TRUNK 30 GAL 8`-10` 4`-6`SHRUB AREASQTYCOMMON NAMEBOTANICAL NAMECONT.HT.SPREADSPACING1,340 US 380US 3805 GAL24"-36" 18"-24" 36"OCSOD/SEEDQTYCOMMON NAMEBOTANICAL NAMECONT.HEIGHTSPREADSPACING39,774 SF BERMUDA GRASS CYNODON DACTYLONSOLID SOD NA NA NAPLANT SCHEDULE US 380PROPOSED PD EXHIBITS Page 1 of 2 To: Planning & Zoning Commission Item No. 5 From: Scott Ingalls, AICP, Senior Planner Through: Alex Glushko, AICP, Planning Manager Re: Planning & Zoning Commission Meeting – January 7, 2020 Agenda Item: Conduct a Public Hearing, and consider and act upon a request to rezone 0.6± acres from Single Family-15 (SF-15) to Downtown Single Family (DTSF), located on the south side of Third Street, east of Coleman Street. (Z19-0022). Description of Agenda Item: The zoning and land use of the surrounding properties are as follows: Zoning Current Land Use Future Land Use Plan Subject Property Single Family-15 Single Family Residential Old Town Single Family North Downtown Single Family Single Family Residential Old Town Single Family East Single Family-15 Single Family Residential Old Town Single Family South Single Family-15 Single Family Residential Old Town Single Family West Single Family-15 Single Family Residential Old Town Single Family Requested Zoning – The purpose of this request is to rezone the property to the Downtown Single Family District to allow for development of three (3) residences in the future. The existing house will be removed. At the time of an application for “straight” zoning, the applicant is not required to submit an exhibit depicting how the property will be specifically developed or elevations of the proposed building. Prior to development, the developer will be required to submit a Replat for review and approval by the Planning & Zoning Commission. The applicant has been advised of the standards necessary for development. Prosper is a place where everyone matters. PLANNING Page 2 of 2 Future Land Use Plan – The Future Land Use Plan recommends Old Town Single Family. The proposed zoning request conforms to the Future Land Use Plan. Thoroughfare Plan – The property does not have direct access to a major or minor thoroughfare. Parks Master Plan – The Parks Master Plan does not indicate a park is needed on the subject property. Legal Obligations and Review: Notification was provided to neighboring property owners as required by State Law. To date, Town staff has not received any Public Hearing Notice Reply Forms. Attached Documents: 1. Aerial and Zoning Maps 2. Exhibit A Staff Recommendation: Staff recommends the Planning & Zoning Commission approve of the request to rezone 0.6± acres from Single Family-15 (SF-15) to Downtown Single Family (DTSF), located on the south side of Third Street, east of Coleman Street. Town Council Public Hearing: Upon a recommendation by the Planning & Zoning Commission, a Public Hearing for this item will be scheduled for the Town Council at their Regular meeting on January 28, 2020. Z19-0022 FIRST ST THIRD ST SECOND ST BROADWAY ST MAIN STCHURCH STCOLEMAN ST±0 150 30075Feet Z19-0022 S-3 PD-80 PD-78 PD-67 SF-15 DTR C DTO C DTO DTO DTSF DTR DTO DTO DTO DTO C C DTO DTSF DTO DTO DTO DTO DTO DTR DTSF DTO M DTO FIRST ST THIRD ST SECOND ST BROADWAY ST MAIN STCHURCH STCOLEMAN ST±0 150 30075Feet LEGENDEXISTINGPROPOSEDPROPERTY LINEPAVEMENTCONTOURWATER LINEEXHIBIT "A" 664-01\dwg\ZONING EXHIBIT.dwgEX-ADesigned by:SHEET1" = 20' JJV Checked by: Scale: Drawn by: vasquez engineering, L.L.C. 1919 S. Shiloh Road Suite 440, LB 44 Garland, Texas 75042 Ph: 972-278-2948 TX Registration # F-12266 THIS DOCUMENT IS FOR INTERIM REVIEW AND IS NOT INTENDED FOR CONSTRUCTION, PERMITTING OR BIDDING PURPOSES JUAN J. VASQUEZ, P.E. TEXAS NO. 85852 DATED 12/20/2019 VASQUEZ ENGINEERING, L.L.C. TX REG. F-12266 JNM JJV 12/20/2019Date: LOTS 4A, LOT 5 & LOT 6, BLOCK13 BRYANS 1ST ADDITION CITY OF PROSPER, TEXAS LOCATION MAPDEVELOPER: MLD HOMES 31 STEEL RD WYLIE, TX. 75098-7048 PROJECTLOCATION LEGAL DESCRIPTION Page 1 of 4 To: Planning & Zoning Commission Item No. 6 From: Alex Glushko, AICP, Planning Manager Re: Planning & Zoning Commission Meeting – January 7, 2020 Agenda Item: Conduct a Public Hearing, and consider and act upon a request to rezone 2.1± acres from Single Family-15 (SF-15) to Planned Development-Downtown Office (PD-DTO), located on the north side of Broadway Street, west of Craig Road. (Z19-0023). Description of Agenda Item: The zoning and land use of the surrounding properties are as follows: Zoning Current Land Use Future Land Use Plan Subject Property Single Family-15 Single Family Residence Old Town-Office North Single Family-15 Single Family Residence Old Town-Single Family East Single Family-15 Single Family Residence Old Town-Office South Single Family-15 Vacant and Single Family Residence Old Town-Office West Single Family-15 Single Family Residence Old Town-Office Requested Zoning – The purpose of this request is to rezone 2.1± acres to a Planned Development allow for the conversion of the existing single family house into a professional office, which is anticipated to be a law office. The existing structure is a two-story, 1,923 square-foot building, and will consist of approximately 5-6 offices located on both stories, for approximately nine (9) employees. The applicant is proposing to construct a total of fifteen (15) parking spaces. Pictures of the existing structure are shown below: Prosper is a place where everyone matters. PLANNING Page 2 of 4 In general, the proposed use is in conformance with the Future Land Use Plan, and staff recommends approval of the request to rezone the property to Downtown Office for use of the existing structure as professional offices. However, the applicant has requested reductions to the minimum landscape setbacks and drive aisle widths in order to allow for a parking lot to be constructed in front of the existing structure, as shown below: Page 3 of 4 Below are details regarding the requested deviations to Town standards: Landscape Setbacks – The Zoning Ordinance requires a minimum fifteen foot (15’) front yard landscape setback and five foot (5’) side yard landscape setback. The applicant is proposing a minimum ten foot (10’) front yard landscape setback along southern property line (Broadway Street), and a minimum two foot (2’) side yard landscape setback along the western property line. Drive Aisle Width – The Zoning Ordinance requires a minimum drive aisle width of twenty-four feet (24’) with ninety-degree parking spaces. The applicant is proposing a minimum twenty-foot (20’) drive aisle width. Planning staff has concerns with the proposed parking lot location being located in front of the existing structure from an aesthetic perspective. Multiple properties along Broadway Street and First Street have (re)developed over the past several years. To date, each has developed the required parking lot in either the rear or side of the property. In this way, the streetscape retains a residential character as houses convert to non-residential uses. Staff has concerns allowing parking in front of the house will begin to set a precedent for other properties that redevelop along Broadway Street and First Street over time. Staff has requested the applicant consider redesigning the site to provide the required parking lot on the side or rear of the property; however, the applicant has indicated a desire to keep the existing detached garage and pool which would prevent parking from being constructed in those locations. From an engineering perspective, staff has concerns with reductions to the landscape setback and drive aisle widths from a maneuverability and stacking standpoint. In general, a twenty-foot (20’) drive aisle causes more challenges with vehicular maneuvering in and out of ninety degree spaces than typical twenty-four-foot (24’) aisles; which causes time-consuming multi-point turning movements. In conjunction, the reduced landscape setback and drive aisle width will result in a reduced “throat depth” (noted in the image above) for the driveway off of Broadway Street to the parking lot. Adequate throat depth is important for the safe stacking of vehicles entering and exiting a street. In consideration of the ultimate cross-section of Broadway Street as outlined in the Old Town Insert Map (shown below), engineering estimates the reduction to the landscape setback and drive aisle will result in less than two (2) vehicle stacking spaces between the main travel lanes on Broadway Street and the parking lot. Ultimately, staff has concerns with the potential of vehicles stacking on Broadway Street in the future. Ultimate Broadway Street Cross-Section Page 4 of 4 Staff supports the request to rezone the subject property to Downtown Office to allow for use of the existing structure as professional offices; however, staff recommends the applicant relocate the proposed parking to the side or rear of the existing structure. Future Land Use Plan – The Future Land Use Plan recommends Old Town Office. The proposed zoning request conforms to the Future Land Use Plan. Thoroughfare Plan – The property has direct access to Broadway Street, a future two-lane divided thoroughfare. The proposed request conforms to the Thoroughfare Plan. Parks Master Plan – The Parks Master Plan does indicate a hike and bike trail is needed on the subject property. Legal Obligations and Review: Notification was provided to neighboring property owners as required by State Law. To date, Town staff has not received any Public Hearing Notice Reply Forms. Attached Documents: 1. Aerial and Zoning Maps 2. Proposed Exhibits A, B, C, D, E, F, and G Staff Recommendation: Staff recommends the Planning & Zoning Commission approve of the request to rezone the property to Downtown Office, subject to relocating the parking to the side and/or rear of the existing structure. Town Council Public Hearing: Upon a recommendation by the Planning & Zoning Commission, a Public Hearing for this item will be scheduled for the Town Council at their Regular meeting on January 28, 2020. Z19-0023 FIFTH ST BROADWAY ST CRAIG RDTHIRD ST LANE STPARVIN STFIELD STPARVIN STFIELD ST±0 150 30075Feet Z19-0023 S-3 PD-93PD-93 PD-21 PD-81 SF-15 OO O SF-15 DTO SF-15 SF-15 DTO C DTO SF-10 DTSF FIFTH ST BROADWAY ST CRAIG RDTHIRD ST LANE STPARVIN STFIELD STPARVIN STFIELD ST±0 150 30075Feet N 89°28'38" E 278.95'S 00°17'51" E 180.42'S 89°23'29" W 278.24'N 00°31'31" W 180.84'///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////SDOHU70217022702070197018447944804478700970087013447644777012701170104462446344757017446744664465446444684469447044594458445744524453445144484460DBL4450444944494473447444474446444544444443444244414440FL-12"CMP=744.90FL-12"CMP=744.63CIRF"PREMEIR"1/2" IRFCIRF"PREMEIR"1/2" IRF2. 9 '6.4'1.9'5.4'1.9'3.1'14.0'30.8'24.2'8.3'2.0'8.3'2.0'14.0'9.1'5.7'4.1'4.1'4.3'2.9'16.6'2.9'9.2'2. 9 '4.8'2.1'5.3'2.1'6.0'2.1'12.2'13.1'2.9'6.4'POOLSPAWOODDECK3 0 ' D R A I N AG E E A S EM E N T C A B . L , PG . 8 4 0 P . R . C . C . T .25' BUILDING LINECAB. L, PG. 840, P.R.C.C.T.25' BUILDING LINECAB. L, PG. 840, P.R.C.C.T.10' BUILDING LINECAB. L, PG. 840, P.R.C.C.T. 10' BUILDING LINECAB. L, PG. 840, P.R.C.C.T.2 STORYFRAMERESIDENCEFF=740.77467476477477467457437447437447457467 4 6 746747748747740741742743744745740741742743744744745746738739740741742743744745735736737734729730731732733730731732733734736737738 739 740 741 742 743 744 737 738 739 740 741 742 743 744 736 735734730731732733731732733734735736737738739739740740 740741742743744739738737736732733734735731 732735736737738739 740741 F.M. 113821' ASPHALT ROADWAY100' R.O.W.729(S 88°46'23" W 278.22')(N 89°00'43" W 278.98')(180.82') (S 00°51'53"W 180.3')15' SANITARY SEWER EASEMENTCAB. L, PG. 840, P.R.C.C.T.15' WATER LINE EASEMENTCAB. L, PG. 840, P.R.C.C.T.16.1' X 31.7'FRAMEGARAGEFF=738.8'FIREPIT1/2" CIRS "EAGLE CONTROL"Z=743.251.1'112.8' 52.7'35.5'LOT 1BLOCK AR & R ESTATEDCAB. L, PG. 840,P.R.C.C.T..LOT 2BLOCK AR & R ESTATEDCAB. L, PG. 840,P.R.C.C.T.LOT 3BLOCK AR & R ESTATEDCAB. L, PG. 840,P.R.C.C.T.CALLED 0.537 ACRESJESSEE BRYAN AUSENBAUGH et uxCORY S. AUSENBAUGHDOC. NO. 20071003001368520,O.P.R.C.C.T.CALLED 0.5102 ACRESDAVID C. HAMBYDOC. NO. 20070102000003930,O.P.R.C.C.T.CALLED 0.426 ACRESMARY ELLEN CISNEROSDOC. NO. 2000-0087860, O.P.R.C.C.T.CALLED 0.432 ACRESJAMES R. THROBRIDGE et uxJOANN THROWBRIDGEVOL. 1707, POG. 101, O.P.R.C.C.T.FRAMEGARAGE3.5'FL-12"CMP=744.49FL-12"CMP=743.17FL-36"RCP=733.33CONCRETE HEADWALLEXISTING ZONING: SF-15LAND USE: SINGLE FAMILYEXISTING ZONING: SF-15LAND USE: SINGLE FAMILYEXISTING ZONING: SF-15LAND USE: SINGLE FAMILYAPPROX. 500' TO NEXT CROSS STREETEXISTING ZONING: SF-15LAND USE: SINGLE FAMILYEXISTING ZONING: SF-15LAND USE: SINGLE FAMILYEXISTING ZONING: SF-15LAND USE: SINGLE FAMILYEXISTING ZONING: SF-15LAND USE: SINGLE FAMILYEAST BROADWAY STREETDATENo.REVISION BYDATE:SHEETFile No.9/3/2019CHECKED:MAMDRAWN:ASDDESIGN:ASD603 BROADWAY CONCEPT PROSPER, TX TEXAS REGISTRATION #141990GRAPHIC SCALE1 inch = ft.2020402010EXHIBIT AEX-A1903 CENTRAL DR. SUITE #1 PHONE: 817.281.0572 BEDFORD, TX 76092 WWW.CLAYMOOREENG.COMCOUNTYSURVEY:ABSTRACT NO.COLLINC.C.S.L.A0147CITY:STATE:PROSPERTEXASLEGAL DESCRIPTION:OWNER:APPLICANT/REPRESENTATIVE:CLAYMOORE ENGINEERING, INC.301 S. COLEMAN, SUITE #40PROSPER, TX 75078PH: 817.201.6982SURVEYOR:EAGLE SURVEYING210 S. ELM STREET, SUITE #104DENTON, TX 76201PH: 940.222.3009DUGAN P KELLEY301 S COLEMAN ST, STE 20PROSPER, TX 75078 CASE # : Z19-0023CONTACT NAME: MATT MOORECONTACT NAME: DAN RICKR & R ESTATES (CPR),BLOCK A, LOT 1,1.156 ACRESSITENVICINITY MAP & EXISTING ZONING MAPN.T.S.603 BROADWAY STREETEXISTING ZONING: SF-15 (2.1101 AC)PROPOSED ZONING: PD (DTO) (2.1101 AC)ACCORDING TO MAP NO. 48085C0235J, DATED JUNE 2, 2009 OF THE NATIONALFLOOD INSURANCE PROGRAM MAP, FLOOD INSURANCE RATE MAP OF COLLINCOUNTY, TEXAS, FEDERAL EMERGENCY MANAGEMENT AGENCY, FEDERALINSURANCE ADMINISTRATION, THIS PROPERTY IS WITHIN ZONE "X", (AREASDETERMINED TO BE OUTSIDE OF THE 0.2% ANNUAL CHANCE FLOODPLAIN). IFTHIS SITE IS NOT WITHIN AN IDENTIFIED SPECIAL FLOOD HAZARD AREA, THISFLOOD STATEMENT DOES NOT IMPLY THAT THE PROPERTY AND/OR THESTRUCTURES THEREON WILL BE FREE FROM FLOODING OR FLOOD DAMAGE.ON RARE OCCASIONS, GREATER FLOODS CAN AND WILL OCCUR AND FLOODHEIGHTS MAY BE INCREASED BY MAN-MADE OR NATURAL CAUSES. THIS FLOODSTATEMENT SHALL NOT CREATE LIABILITY ON THE PART OF THE SURVEYOR.FLOODPLAIN NOTECONTACT NAME: DUGAN P KELLEYPRELIMINARYCLAYMOORE ENGINEERING EXHIBIT B – STATEMENT OF INTENT AND PURPOSE December 9, 2019 Planning Dept. City of Prosper 407 E. 1st St. Prosper, Texas 75078 Re: PD Zoning Request 603 Broadway Street Letter of Intent To whom it may concern, Please let this letter serve as the Letter of Intent for the PD Zoning request associated with the proposed development located at 603 Broadway Street. The subject tract is currently zoned SF-15. The proposed office space is 1,923 square feet. The specific PD standards requested as part of this submittal are further detailed in Exhibit C attached. Should you have any questions, please feel free to contact me. Sincerely, Claymoore Engineering, Inc. 301 S. Coleman, Suite 40 Prosper, TX 75078 817-281-0572 Thank you and please call if you have any comments or need additional information. Sincerely, Drew Donosky, P.E. RECEIVED 12/9/19 Z19-0023 EXHIBIT “C” DEVELOPMENT STANDARDS Conformance with the Town’s Zoning Ordinance and Subdivision Ordinance: Except as otherwise set forth in these Development Standards, the regulations of the Town’s Zoning Ordinance (Ordinance No. 05-20), as it exists or may be amended, and the Subdivision Ordinance, as it exists or may be amended, shall apply. 1. Except as noted below, the Tract shall continue to be used in accordance with the Downtown Office (DTO) District, as it exists or may be amended. 2. Development Plans A. Conceptual Site Plan: The tract shall continue to be used in general accordance with the attached concept plan, set forth in Exhibit D. B. Building Elevations: The tract shall continue to be used in general accordance with the attached façade plans, set forth in Exhibit F. C. Landscape Plan: The tract shall continue to be used in general accordance with the attached landscape plan, set forth in Exhibit G. 3. Regulations: A. Landscape Setbacks: 1. Minimum Front Yard – Ten feet (10’). 2. Minimum Side Yard – Two feet (2’). B. Parking: 1. Minimum Drive Aisle – Twenty feet (20’). 2. Maximum fifteen (15) parking spaces shall be permitted on dead-end drive aisles. C. Screening: 1. Shall be required in accordance with the Zoning Ordinance, as it exists or may be amended. A solid living screen in lieu of required screening shall be permitted, as follows: a. One (1) large tree, three (3) inch caliper minimum, on thirty (30) foot centers and eight (8) foot, 45-gallon, evergreen shrubs, on six (6) foot centers. 1 CARPORT18'20'10.5'CARPORT OVHD2.82'19.65'13.09'26'18'24'N 89°28'38" E 278.95'S 00°17'51" E 180.42'S 89°23'29" W 278.24'N 00°31'31" W 180.84'///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////SDOHU70217022702070197018447944804478700970087013447644777012701170104462446344757017446744664465446444684469447044594458445744524453445144484460DBL4450444944494473447444474446444544444443444244414440FL-12"CMP=744.90FL-12"CMP=744.63CIRF"PREMEIR"1/2" IRFCIRF"PREMEIR"1/2" IRF2. 9 '6.4'1.9'5.4'1.9'3.1'14.0'30.8'24.2'8.3'2.0'8.3'2.0'14.0'9.1'5.7'4.1'4.1'4.3'2.9'16.6'2.9'9.2'2. 9 '4.8'2.1'5.3'2.1'6.0'2.1'12.2'13.1'2.9'6.4'POOLSPAWOODDECK3 0 ' D R A I N AG E E A S EM E N T C A B . L , PG . 8 4 0 P . R . C . C . T .25' BUILDING LINECAB. L, PG. 840, P.R.C.C.T.25' BUILDING LINECAB. L, PG. 840, P.R.C.C.T.10' BUILDING LINECAB. L, PG. 840, P.R.C.C.T. 10' BUILDING LINECAB. L, PG. 840, P.R.C.C.T.2 STORYFRAMERESIDENCEFF=740.77467476477477467457437447437447457467 4 6 746747748747740741742743744745740741742743744744745746738739740741742743744745735736737734729730731732733730731732733734736737738 739 740 741 742 743 744 737 738 739 740 741 742 743 744 736 735734730731732733731732733734735736737738739739740740 740741742743744739738737736732733734735731 732735736737738739 740741 F.M. 113821' ASPHALT ROADWAY100' R.O.W.729(S 88°46'23" W 278.22')(N 89°00'43" W 278.98')(180.82') (S 00°51'53"W 180.3')15' SANITARY SEWER EASEMENTCAB. L, PG. 840, P.R.C.C.T.15' WATER LINE EASEMENTCAB. L, PG. 840, P.R.C.C.T.16.1' X 31.7'FRAMEGARAGEFF=738.8'FIREPIT1/2" CIRS "EAGLE CONTROL"Z=743.251.1'112.8' 52.7'35.5'LOT 1BLOCK AR & R ESTATEDCAB. L, PG. 840,P.R.C.C.T..LOT 2BLOCK AR & R ESTATEDCAB. L, PG. 840,P.R.C.C.T.LOT 3BLOCK AR & R ESTATEDCAB. L, PG. 840,P.R.C.C.T.CALLED 0.537 ACRESJESSEE BRYAN AUSENBAUGH et uxCORY S. AUSENBAUGHDOC. NO. 20071003001368520,O.P.R.C.C.T.CALLED 0.5102 ACRESDAVID C. HAMBYDOC. NO. 20070102000003930,O.P.R.C.C.T.CALLED 0.426 ACRESMARY ELLEN CISNEROSDOC. NO. 2000-0087860, O.P.R.C.C.T.CALLED 0.432 ACRESJAMES R. THROBRIDGE et uxJOANN THROWBRIDGEVOL. 1707, POG. 101, O.P.R.C.C.T.FRAMEGARAGE3.5'FL-12"CMP=744.49FL-12"CMP=743.17FL-36"RCP=733.33CONCRETE HEADWALLEXISTING ZONING: SF-15LAND USE: SINGLE FAMILYEXISTING ZONING: SF-15LAND USE: SINGLE FAMILYEXISTING ZONING: SF-15LAND USE: SINGLE FAMILYAPPROX. 500' TO NEXT CROSS STREETEXISTING ZONING: SF-15LAND USE: SINGLE FAMILYEXISTING ZONING: SF-15LAND USE: SINGLE FAMILYEXISTING ZONING: SF-15LAND USE: SINGLE FAMILYEXISTING ZONING: SF-15LAND USE: SINGLE FAMILYEAST BROADWAY STREETDATENo.REVISION BYDATE:SHEETFile No.9/3/2019CHECKED:MAMDRAWN:ASDDESIGN:ASD603 BROADWAY CONCEPT PROSPER, TX TEXAS REGISTRATION #141990GRAPHIC SCALE1 inch = ft.2020402010EXHIBIT DEX-D1903 CENTRAL DR. SUITE #1 PHONE: 817.281.0572 BEDFORD, TX 76092 WWW.CLAYMOOREENG.COMCOUNTYSURVEY:ABSTRACT NO.COLLINC.C.S.L.A0147CITY:STATE:PROSPERTEXASLEGAL DESCRIPTION:OWNER:APPLICANT/REPRESENTATIVE:CLAYMOORE ENGINEERING, INC.301 S. COLEMAN, SUITE #40PROSPER, TX 75078PH: 817.201.6982SURVEYOR:EAGLE SURVEYING210 S. ELM STREET, SUITE #104DENTON, TX 76201PH: 940.222.3009DUGAN P KELLEY301 S COLEMAN ST, STE 20PROSPER, TX 75078 CASE # : Z19-0023CONTACT NAME: MATT MOORECONTACT NAME: DAN RICKR & R ESTATES (CPR),BLOCK A, LOT 1,1.156 ACRESSITENVICINITY MAP & EXISTING ZONING MAPN.T.S.603 BROADWAY STREETEXISTING ZONING: SF-15 (2.1 AC) PROPOSED ZONING: PD (DTO) (2.1 AC)ACCORDING TO MAP NO. 48085C0235J, DATED JUNE 2, 2009 OF THE NATIONALFLOOD INSURANCE PROGRAM MAP, FLOOD INSURANCE RATE MAP OF COLLINCOUNTY, TEXAS, FEDERAL EMERGENCY MANAGEMENT AGENCY, FEDERALINSURANCE ADMINISTRATION, THIS PROPERTY IS WITHIN ZONE "X", (AREASDETERMINED TO BE OUTSIDE OF THE 0.2% ANNUAL CHANCE FLOODPLAIN). IFTHIS SITE IS NOT WITHIN AN IDENTIFIED SPECIAL FLOOD HAZARD AREA, THISFLOOD STATEMENT DOES NOT IMPLY THAT THE PROPERTY AND/OR THESTRUCTURES THEREON WILL BE FREE FROM FLOODING OR FLOOD DAMAGE.ON RARE OCCASIONS, GREATER FLOODS CAN AND WILL OCCUR AND FLOODHEIGHTS MAY BE INCREASED BY MAN-MADE OR NATURAL CAUSES. THIS FLOODSTATEMENT SHALL NOT CREATE LIABILITY ON THE PART OF THE SURVEYOR.FLOODPLAIN NOTECONTACT NAME: DUGAN P KELLEYPRELIMINARYCLAYMOORE ENGINEERINGLEGENDLIGHT DUTY CONCRETE PAVEMENTPROPOSED CONCRETE CURB AND GUTTERPROPERTY LINESITE DATA TABLEPROPOSEDZONINGPROPOSEDUSELOT SIZE(ACRES)LOT SIZE(SQ. FT.)TOTAL BLDG. AREA(SQ. FT.)BLDG. HGT.(FT.)LOTCOVERAGE(50% MAX)DTO OFFICE 1.15650,3551,9232- STORY 3.82%OPENSPACEPROVIDEDREQ OPENSPACE (7%)(SQ, FT)3,524.85 40,890FLR AREARATIO(0.5:1 MAX)0.08:1 Exhibit E – 603 Broadway Street Development Schedule Below is an anticipated project schedule for the proposed Graff El Dorado Motors Schedule in accordance with the submittal checklist. This schedule is conceptual and subject to change based on permitting/entitlements. The proposed developer is working on obtaining the required manufacturer approvals for the subject tract. Once obtained, then the permitting approvals will start with the Town. Zoning Submittal to Town – 12/09/19 Zoning Approval from Town – 02/11/20 Final Site Plan Submittal to Town – 02/17/20 Final Site Plan Approval from Town – 03/06/20 Submit Building Permit – 03/06/20 Final Engineering Approval from Town – 03/06/20 Building Permit Issuance – 03/20/20 Start Construction – 03/21/20 Construction Complete – 05/31/20 Thank you and please call if you have any comments or need additional information. Sincerely, Drew Donosky, P.E. OHU4479448044787009700870134476447770127011701044624463447570174467446644654464446844694470445944584457445244534451444844604450444944494473447444474446444544444443444244414440POOLSPA25' BUILDING LINECAB. L, PG. 840, P.R.C.C.T.7467476477477467457437447437447457467467467477487740741742743744745740741742743744744745746738739740741742743744745735736737734729730731732733730731732733734 736 737 738739740741742743744737738739740741742743744736735 734 730 731 732 733 731732733734735736737738739739740740740741742743744739738737736732 733 734 735731732 735736737 738739740 741F.M. 113821' ASPHALT ROADWAY100' R.O.W.729FIREPIT1/2" CIRS "EAGLE CONTROL"Z=743.25LOT 1BLOCK AR & R ESTATEDCAB. L, PG. 840,P.R.C.C.T..LOT 2BLOCK AR & R ESTATEDCAB. L, PG. 840,P.R.C.C.T.LOT 3BLOCK AR & R ESTATEDCAB. L, PG. 840,P.R.C.C.T.CALLED 0.537 ACRESJESSEE BRYAN AUSENBAUGH et uxCORY S. AUSENBAUGHDOC. NO. 20071003001368520,O.P.R.C.C.T.CALLED 0.5102 ACRESDAVID C. HAMBYDOC. NO. 20070102000003930,O.P.R.C.C.T.CALLED 0.426 ACRESMARY ELLEN CISNEROSDOC. NO. 2000-0087860, O.P.R.C.C.T.CALLED 0.432 ACRESJAMES R. THROBRIDGE et uxJOANN THROWBRIDGEVOL. 1707, POG. 101, O.P.R.C.C.T.2,000 ± SFOFFICE BUILDINGTXTXTXTXTXTXTXTXTXTXTXTXTXTXRYRYRYRYRYWMRYRYRYRYRYRYDBPMPMPMPMPMDBDBDBDBDBDBDBWMWMWMWMWMWMWMWMWMSOSOSODBDBDBDBDBDBDBDBDBDBDBCR-TRBRBRBRBRBRBRBRBRBTYTYTYTYTYCRCRCRRBRBRBRBTYTYRBRBRBRBPMPMPMPMPMPMPMPMPMDBTXTXTXTXTXTXTXTXTXTXTXRYRYRYRYRYRYRYRYWMWMWMWMWMWMPMPMPMPMTXTXPMDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBDBTXTXTXTXTXWMWMWMWMWMCSCSCSCSCSYUYUYUYUCSYUYUYUYUWMWMWMTXTXTXGLGLGLGLGLTXWMGLGLGLGLWMWMWMWMDBDBWMWMCR-TCR-TCR-TCR-TCR-TCR-TCR-TCR-TCR-TCR-TCR-TCR-TCR-TCR-TCR-TCR-TCRNNNN5' LANDSCAPEBUFFER5' LANDSCAPEBUFFERDATE:SHEETFile No.12/6/2019CHECKED:MAMDRAWN:ASDDESIGN:ASD603 BROADWAY CONCEPTPROSPER, TXTEXAS REGISTRATION #141991903 CENTRAL DR. SUITE #1 PHONE: 817.281.0572BEDFORD, TX 76092 WWW.CLAYMOOREENG.COMH L-1EXHIBIT GLANDSCAPE PLAN.UHNMOSAJETS TA3OF97ETXRFPY 0GRAPHIC SCALE1 inch = ft.TREE LEGENDCanopy TreesCedar ElmSOShumard OakSHRUB LEGENDInstall 4" steel edging between all shrub beds and grassareas.Install 4" layer of shredded hardwood mulch to all plantingbeds.The project will have an undergound automatic irrigationsystem to water all new plantings.LANDSCAPE NOTES1.2.3.4.Shrub beds to have 12 inches of prepared planting mix(75% import topsoil, 15% composted amendment, 10%washed sand)5.Shredded hardwood mulch must contain long strandsalong with double shred finer material obtained from alocal source.6.Install 4 inches of clean topsoil in all areas of the site disturbedby grading and construction operations. Topsoil shall be freefrom sticks, debris and rocks larger than 2 inches in diameterand have an organic matter level of 3 percent minimum and apH range between 5.5 and 7.4 percent. Provide soil testanalysis from a soil test laboratory showing soil makeup andorganic percentage.7.Solid sod or hydromulch all areas disturbed byconstruction activities.Ornamental TreesCR-TCrapemyrtle'Tuscarora'4010202020Giant LiriopeRed YuccaDwarf Burford HollyGLRYDBDwarf Wax MyrtleWMTexas SageTXPink MuhlyPMCherry SageCSTwistleaf YuccaYUCR-NCrapemyrtle'Natchez'TYTree YauponRedbudRB DATE:SHEETFile No.12/31/2019CHECKED:MAMDRAWN:ASDDESIGN:ASD603 BROADWAY CONCEPTPROSPER, TXTEXAS REGISTRATION #141991903 CENTRAL DR. SUITE #1 PHONE: 817.281.0572BEDFORD, TX 76092 WWW.CLAYMOOREENG.COMLandscape Plan is conceptual in nature. Must meet all required Zoning requirements Landscape CalculationsTown of Prosper, Texas Interior Landscape AreaProvided1 tree / 15 spacesRequired13 spaces1 tree per 30 LF1 treeProvidedRequiredStreet Landscape AreaAt least 1 tree within 150'of each parking space.15 shrubs per 30 LF15 sf area for each parking space195 SF 331 SFPerimeter LandscapeProvidedRequired1 tree and 1 shrub per 15 LF13 trees13 shrubsWest property line13 trees13 shrubs180.84 LF10 trees278 LFFM 1138150 shrubs 150 shrubs1 tree7 ex. trees + 3 newNorth property line19 trees19 shrubs278.95 LF19 trees19 shrubsEast property line13 trees13 shrubs180.42 LF 13 trees14 shrubsH L-2EXHIBIT GLANDSCAPE DETAILS.UHNMOSAJETS TA3OF97ETXRFPY WATER BASINSHRUB PLANTINGSEE PLANTRIANGULARSPACINGSCALE: NONEEQUALMULTI-TRUNK PLANTINGPREPARE SOIL MIXAND FERTILIZERPER SPECS.TOP OF BALL ORROOT CROWN1" ABOVE FIN.STEEL EDGINGSEE PLANGRADEPLACING PREPARED MIXSCARIFY BOTTOM OFPLANTING BED BEFOREEQUALPREPARED SOIL MIXAND FERTILIZER (SEE SPECS)12"4" MULCH LAYERSCALE: NONE4"NATIVE SOIL4" MULCH LAYER4" MULCH LAYER12" DEPTH OFPLANTING MIXTRIANGULARSPACINGEQUALEQUALSCALE: NONEGROUNDCOVER PLANTING2348"DETAIL FORARBOR-GUYREFER TO ANCHORINGSTEEL EDGINGSEE PLANCANOPY TREE PLANTINGSCALE: NONE1TREE STAKE SOLUTIONS LLC9973 FM 521 ROADROSHARON, TX 77583PHONE: (281) 778-1400FAX: (281) 778-1425www.treestakesolutions.com™SolutionsUNDISTURBEDSOILNAILSTAKEROOT ANCHORU-BRACKETROOTBALLPLANTING HOLEUNDISTURBEDSOILROOT ANCHORU-BRACKETROOTBALLPLANTING HOLETREETREENAIL STAKEPLANTING HOLETREEU-BRACKETROOT ANCHORTREE TRUNKROOTBALL1. WITH TREE IN A STRAIGHT & PLUMBPOSITION, CENTER THE APPROPRIATE ROOTANCHOR SAFETY STAKE AROUND THE TRUNK,WITH RINGS LAYING FLAT AGAINSTROOTBALL, U-BRACKETS FACING UP.2. INSERT 1 OF 3 NAIL STAKES THROUGH EACH OFTHE U-BRACKETS. NAILS SHOULD REST IN THEUNDISTURBED SOIL AT THE BOTTOM OF THE TREEPIT. ALL NAILS SHOULD FIT SNUG AGAINST THE SIDEOF THE ROOTBALL.(FOR HAND OR MACHINE DUG TREES, IT MAY BENECESSARY TO PENETRATE 1" - 4" OF OUTER AREAOF THE ROOTBALL WITH THE NAIL.)3. NAIL STAKES SHOULD BE DRIVEN STRAIGHT DOWNINTO THE UNDISTURBED SOIL BELOW THEROOTBALL. THE NAILS ARE NOW CAGING THEROOTBALL IN PLACE, WHILE THE TOP BRACKET PINSTHE ROOTBALL DOWN.AFTER THE TREE STAKE IS INSTALLED, A LAYER OFMULCH CAN BE ADDED OVER THE STAKE. REMOVEROOT ANCHOR AFTER TREE IS ESTABLISHED.ITEM #5 BG15 BG30 BG45/65 BGDESCRIPTION5 GALLON OR 10" ROOTBALL10/15 GALLON OR 17" ROOTBALL20/30 GALLON OR 22" ROOTBALL45/65 GALLON OR 27-30" ROOTBALLNAIL LENGTH X 3PC(INCLUDED)#4 X 24"#4 X 36"#4 X 36"#4 X 48"ITEM #100 BG150 BG200 BG300 BGDESCRIPTION95/100 GALLON OR 36" ROOTBALL150 GALLON OR 42" ROOTBALL200 GALLON OR 48" ROOTBALL300 GALLON OR 58" ROOTBALLNAIL LENGTH X 3PC(INCLUDED)#5 X 48"#5 X 60"#5 X 72"#5 X 72"ROOT ANCHORTM BELOW GRADE SAFETY STAKE SIZING CHARTTREE LISTRRRTree YauponPLANT LISTIlex vomitoria30 gal. 8' ht. multi-trunk female30 gal. 8' ht. 3 trunk 3" cal. min.Lagerstroemia indica 'Tuscarora'Tuscarora Crapemyrtle30 gal. 8' ht. multi-trunk 3" cal. min.Cercis canadensisRedbud5 gal. 36" ocLiriope giganteaGiant Liriope5 gal. 36" ocHesperaloe parvifloraRed Yucca5 gal. 36" ocIlex cornuta 'Burfordii'Dwarf Burford HollyShumard OakQuercus shumardiiTYCR-TRBGLRYDBSO5 gal. 36" ocMyrica pusillaDwarf Wax MyrtleWMCANOPY TREESORNAMENTAL TREESSHRUBS & GROUNDCOVERS5 gal. 36" ocLeucophyllum frutescens 'Silverado'Texas SageTX5 gal. 36" ocMuhlenbergia capillarisPink MuhlyPM5 gal. 36" ocSalvia greggiiCherry SageCS5 gal. 36" ocYucca rupicolaTwistleaf YuccaYU3" cal. 11' ht. 5' spread717179196833136196830 gal. 8' ht. 3 trunk 3" cal. min.Lagerstroemia indica 'Natchez'Natchez CrapemyrtleCR-N4R = Removed treeTown of Prosper Notes RESULTS Page 1 of 3 ] Prosper is a place where everyone matters. (Councilmembers Dixon & Miller Absent) Call to Order/ Roll Call. Invocation, Pledge of Allegiance and Pledge to the Texas Flag. Announcements of recent and upcoming events. Presentations. 1. Presentation of the GFOA Achievement of Excellence in Financial Reporting award to members of the Finance Department for the Town’s Comprehensive Annual Financial Report for the Fiscal Year ending September 30, 2018. (BP) Discussion Items. 2. Grant Committee Update. (KB) CONSENT AGENDA: All Consent Agenda Items Approved, 5-0 Items placed on the Consent Agenda are considered routine in nature and non-controversial. The Consent Agenda can be acted upon in one motion. Items may be removed from the Consent Agenda by the request of Council Members or staff. 3. Consider and act upon the Minutes from the November 26, 2019, Town Council Meeting. (RB) 4. Receive the October Financial Report. (BP) 5. Consider and act upon awarding RFP No. 2020-19-B for Stop Loss Coverage to QBE effective January 1, 2020, and authorizing the Town Manager to execute all documents for the same. (KS) 6. Consider and act upon approving the purchase of Adaptive Consumer Engagement (ACE) software license, maintenance, and support from Aclara, a sole source provider; and authorizing the Town Manager to execute the same. (CS) 7. Consider and act upon approving the purchase of computer hardware, from Centre Technologies, Inc., through the Texas Department of Information Resources (DIR) Purchasing Contract. (LJ) 8. Consider and Act upon approving an Interlocal Agreement (ILA) with Collin County for the Funding Assistance Program to partially fund the construction of the Whitley Place Powerline Trail project and authorize the Town Manager to execute documents for the same. (PN) Agenda Prosper Town Council Meeting Council Chambers Prosper Town Hall 250 W. First Street, Prosper, Texas Tuesday, December 10, 2019 5:45 PM RESULTS Page 2 of 3 9. Consider and act upon approving the purchase of Traffic Signal related items for the Fishtrap & Teel Parkway Traffic Signal improvement project, from Consolidated Traffic Controls, Inc., through the Houston-Galveston Area Council (HGAC) Cooperative Purchasing Program. (PA) 10. Consider and act upon an ordinance amending Planned Development-68 (PD-68) in its entirety for Shops at Prosper Trail, on 33.2± acres, located on the northeast corner of Preston Road and Prosper Trail, generally to modify the development standards, including modified parking regulations and architectural design. (Z19-0017). (AG) 11. Consider and act upon authorizing the Town Manager to execute a Development Agreement between MQ Prosper Retail, LLC, and the Town of Prosper, Texas, related to an inside auto parts sales structure and a multitenant office/retail structure, located on the east side of Preston Road, north of Prosper Trail. (AG) 12. Consider and act upon a Site Plan, Landscape Plan, and Façade Plan for a multi - tenant office/retail building (Ebby Halliday), on 1.4± acres, located on the east side of Preston Road, north of Prosper Trail. The property is zoned Planned Development- 68 (PD-68). (D19-0110). (AG) 13. Consider and act upon whether to direct staff to submit a written notice of appeal on behalf of the Town Council to the Development Services Department, pursuant to Chapter 4, Section 1.5(C)(7) and 1.6(B)(7) of the Town’s Zoning Ordinance, regarding action taken by the Planning & Zoning Commission on any Site Plan or Preliminary Site Plan. (AG) Citizen Comments: Items for Individual Consideration: 14. Consider and act upon an ordinance amending Ordinance No. 18-71 (FY 2018-2019 Budget). (BP) Approved, 5-0 15. Consider and act upon an ordinance amending Ordinance No. 19-65 (FY 2019-2020 Budget). (BP) Approved, 5-0 16. Consider and act upon authorizing the Town Manager to execute a Professional Services Agreement between Teague Nall and Perkins, Inc., and the Town of Prosper, Texas, related to the design of Fishtrap Road from Stuber Elementary School to the Dallas North Tollway Project. (PA) Approved, 5-0 17. Consider and act upon authorizing the Town Manager to execute a Professional Services Agreement between Teague Nall and Perkins, Inc., and the Town of Prosper, Texas, related to the design of First Street from Coit Road to Custer Road Project. (PA) Approved, 5-0 Executive Session: Recess into Closed Session in compliance with Section 551.001 et seq. Texas Government Code, as authorized by the Texas Open Meetings Act, to deliberate regarding: Section 551.087 – To discuss and consider economic development incentives. Section 551.072 – To discuss and consider purchase, exchange, lease or value of real property for municipal purposes and all matters incident and related thereto. RESULTS Page 3 of 3 Section 551.074 - To discuss and consider personnel matters and all matters incident and related thereto. Reconvene in Regular Session and take any action necessary as a result of the Closed Session. Possibly direct Town staff to schedule topic(s) for discussion at a future meeting. 18. Downtown Live! Update. (DR)